WPMR91S, the refrigerator requires exactly 13 grams of R600a refrigerant.

Based on the data provided in the nameplate, the refrigerator requires exactly 13 grams of R600a refrigerant.


Technical Specification Table

Feature Details
Model White Point WPMR91S
Utilization LBP (Low Back Pressure)
Domaine Cooling (Mini-Bar / Domestic Refrigerator)
Oil Type and Quantity Mineral or Ester Oil (approx. 160ml)
Horsepower (HP) 1/12 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240V / 50Hz
Cooling Capacity BTU Approx. 310 BTU/h
Motor Type RSIR (Resistance Start – Induction Run)
Displacement 4.0 cm³ to 4.5 cm³
Winding Material Copper
Pression Charge 0.5 to 1 PSI (Low side running)
Capillary 0.026 ID
Compatible Models Compact refrigerators, Under-counter coolers
Temperature Function +5°C to -18°C (Internal)
With Fan or No No (Static Cooling)
Commercial or No No (Domestic)
Amperage in Function 0.50 A
LRA 2.6 A
Type of Relay PTC Relay
Capacitor No (Standard RSIR)

Compressor Replacements

5 Replacements (Same Gas – R600a):

  • Jiaxipera T1110Y
  • Danfoss/Secop TLES4KK.3
  • Embraco EMX20CLC
  • Huayi B43H
  • Wanbao ASD43Y

5 Replacements (Other Gas – R134a – Requires Flushing):

  • Embraco EMI 30HER
  • Jiaxipera ZBS1111cy
  • Danfoss TLS3F
  • Donper S43CZ
  • Cubigel GL45AA

Mbsmpro.com, White Point, WPMR91S, Refrigerator, 1/12 hp, R600a, 13g, 0.50 A, 220-240V 50Hz, LBP, Made in Turkey

The White Point WPMR91S represents the modern standard for compact, energy-efficient refrigeration. Manufactured in Turkey, this unit is specifically designed for domestic cooling applications, utilizing the thermodynamic advantages of R600a (Isobutane). Unlike older systems that used heavy refrigerant loads, this high-efficiency cycle operates with a precision charge of only 13 grams.

Thermodynamics and Efficiency

The WPMR91S is built around a Low Back Pressure (LBP) cycle. With a rated current of 0.50 Amperes, the electrical footprint is remarkably low. The integration of R600a allows the compressor to operate at lower pressures compared to R134a, which reduces mechanical wear on the piston and valves, extending the lifespan of the motor.

Engineering Comparison: R600a vs. R134a

Technical Parameter WPMR91S (R600a) Equivalent R134a Unit
Mass Charge 13g ~45g – 60g
Operating Pressure Below Atmospheric (Vacuum) Positive Pressure
COP (Efficiency) Higher Lower
Environmental Impact GWP 3 (Eco-Friendly) GWP 1430 (High Impact)

Professional Maintenance Notice

As an expert in the field, I must emphasize that when servicing the WPMR91S, the 13g charge is critical. Because the volume is so small, traditional manifold gauges can trap a significant percentage of the gas in the hoses.

  • Scale Precision: Use a digital scale accurate to 1 gram.
  • Vacuum: A deep vacuum is mandatory as R600a systems are highly sensitive to moisture and non-condensables.
  • Safety: R600a is flammable. Ensure no open flames or sparks are present during the charging process.

Benefits for the End User

The primary benefit of this specific engineering setup is the Isolation Degree IPX4, which provides protection against moisture ingress, making it ideal for various climates. The use of a PTC relay instead of a mechanical start relay further reduces the “click” noise during startup, providing a quieter user experience.


Focus Keyphrase: White Point WPMR91S Refrigerator R600a 13g Compressor

SEO Title: Mbsmpro.com | White Point WPMR91S Specs | R600a 13g Refrigerator Guide

Meta Description: Full technical data for White Point WPMR91S. Features 13g R600a refrigerant, 0.50A current, and 1/12 HP compressor details. Expert guide for replacement and repair.

Slug: white-point-wpmr91s-refrigerator-specs-r600a-13g

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, White Point, WPMR91S, R600a, Compressor Replacement, Jiaxipera T1110Y, Danfoss TLES4KK.3, Embraco EMX20CLC, Refrigerator Repair Turkey, 1/12 HP Compressor

Excerpt: The White Point WPMR91S is a high-efficiency 91-liter refrigerator utilizing a specialized 13-gram R600a refrigerant charge. Operating at 0.50A, this Turkish-made unit is designed for optimal LBP performance. This guide provides comprehensive technical specifications, compressor cross-references, and engineering insights for professional technicians and hobbyists looking for reliable maintenance data and replacement parts.

WPMR91S, the refrigerator requires exactly 13 grams of R600a refrigerant. mbsmpro
WPMR91S, the refrigerator requires exactly 13 grams of R600a refrigerant. mbsmpro



not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA).

Based on the technical specifications of both compressors, it is not recommended to replace the burnt-out compressor (Jiaxipera N1113Y) with the second one (ACC HTK70AA).

Here is the technical comparison:

1. The Original Compressor (Jiaxipera N1113Y)

  • Displacement: 8.9 cm³
  • Cooling Capacity: Approximately 154 Watts
  • Horsepower Equivalent: Roughly 1/6 HP
  • Gas Type: R600a

2. The Replacement Compressor (ACC HTK70AA)

  • Displacement: 6.64 cm³
  • Cooling Capacity: Approximately 117 Watts
  • Horsepower Equivalent: Roughly 1/8 HP
  • Gas Type: R600a

Why this is a bad match:

While both compressors use the same refrigerant (R600a) and voltage (220-240V), the ACC HTK70AA is significantly weaker than the original Jiaxipera.

If you install it, the following problems will occur:

  1. Poor Cooling: The fridge will take a very long time to get cold, and it may never reach the desired temperature, especially in hot weather.
  2. Continuous Running: Because the compressor is undersized, it will stay “on” almost all the time to try to cool the unit.
  3. Short Lifespan: Working continuously will cause the replacement compressor to overheat, leading to a very short life before it burns out as well.

Conclusion:

You should look for a replacement compressor that has a cooling capacity of around 150–160 Watts or a displacement of 8.9 cm³ (equivalent to 1/6 HP). Using the 1/8 HP compressor (the ACC model) will likely result in a failed repair.



Focus Keyphrase:
 Technical analysis of Jiaxipera N1113Y and ACC HTK70AA compressor replacement compatibility

SEO Title: Mbsmpro.com, Compressor, Jiaxipera N1113Y, ACC HTK70AA, 1/6 hp, 1/8 hp, R600a, 220-240V, Cooling, LBP

Meta Description: Detailed technical review of the Jiaxipera N1113Y and ACC HTK70AA compressors. Learn why cooling capacity and displacement matter more than just the refrigerant type when performing a replacement.

Slug: jiaxipera-n1113y-vs-acc-htk70aa-compressor-technical-specifications

Tags: Jiaxipera N1113Y, ACC HTK70AA, R600a, Compressor, 1/6 hp, 1/8 hp, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GL90AA, HTK80AA, GVY66AA, EMT43HDP, NLE11KK, QP91Y, Wanbao ETB80Y, Embraco EMT43HDP, Secop NLE11KK

Excerpt: Selecting the right compressor for a refrigeration system is critical for long-term performance and energy efficiency. When replacing a Jiaxipera N1113Y, simply matching the refrigerant type is not enough. This guide breaks down the technical differences between the N1113Y and the ACC HTK70AA, providing the essential data for professional technicians and refrigeration engineers.


Technical Article: The Engineering Reality of Compressor Sizing

In the field of refrigeration, a compressor is the heart of the system. For an expert technician, replacing a unit isn’t just about finding a motor that fits the mounting bracket; it is a calculation of thermal dynamics. A common question arises when a Jiaxipera N1113Y fails: Can an ACC HTK70AA serve as a reliable substitute?

The short answer is no. To understand why, we must look at the displacement and the cooling capacity (Watts). The Jiaxipera N1113Y is a powerhouse in its class, designed for medium-to-large domestic refrigerators. It features a displacement of 8.9 cm³ and delivers approximately 154 Watts of cooling at Low Back Pressure (LBP) conditions.

In contrast, the ACC HTK70AA is a smaller unit. With a displacement of only 6.64 cm³, it produces around 117 Watts. When an undersized compressor like the HTK70AA is installed in a system designed for a 154W load, the compressor will run continuously, overheat, and eventually experience mechanical failure or winding burnout.

Comparative Analysis Table

Feature Jiaxipera N1113Y ACC HTK70AA Impact of Difference
Displacement 8.9 cm³ 6.64 cm³ Lower volume per stroke
Cooling Capacity 154 W (~1/6 HP) 117 W (~1/8 HP) 24% loss in cooling power
Current (LRA) ~7.5 A ~6.1 A Different torque characteristics
Efficiency (COP) High Efficiency Standard Efficiency Increased energy consumption

Why “Close Enough” Isn’t Good Enough

When you install a 1/8 HP compressor where a 1/6 HP unit is required, the internal pressures of the refrigeration cycle change. The suction pressure will remain higher than intended because the smaller piston cannot evacuate the evaporator quickly enough. This leads to poor frost patterns and higher cabinet temperatures, especially during high ambient summer conditions.

Technical Specifications Table (Jiaxipera N1113Y)

Model Jiaxipera N1113Y
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing and Deep Cooling
Oil Type and quantity Mineral/PAG (check label) 180ml
Horsepower (HP) 1/6 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240V ~ 50Hz
Cooling Capacity BTU ~525 BTU/h
Motor Type RSIR / RSCR
Displacement 8.9 cm³
Winding Material Copper/Aluminum Alloy (Model Dependent)
Pression Charge Low Pressure Side
Capillary 0.026 to 0.031 inch (standard)
Refrigerator Type No-Frost / Double Door 300L-400L
Temperature Function -35°C to -15°C
With fan or no Usually Static (No fan required)
Commercial or no Domestic / Light Commercial
Amperage in function 0.7 A – 0.9 A
LRA (Locked Rotor Amps) 7.5 A
Type of relay PTC Relay
Capacitor 4µF to 5µF (Optional for RSCR)

Replacement Options for Jiaxipera N1113Y

5 Recommended Replacements (Same Gas: R600a)

  1. ACC HTK80AA: A closer match with 8.1 cm³ displacement.
  2. Secop NLE11KK: High-efficiency replacement for 1/6 HP+ applications.
  3. Embraco EMT43HDP: Robust performance for R600a systems.
  4. Wanbao ETB80Y: Reliable Asian-market equivalent.
  5. Jiaxipera N1112Y: Slightly lower power but within tolerance levels.

5 Recommended Replacements (Other Gas: R134a – Requires System Flush)

  1. ZMC GL90AA: The industry standard for 1/6 HP R134a.
  2. Embraco GVY66AA: High-performance LBP unit.
  3. Donper QP91Y: Reliable 1/6 HP displacement equivalent.
  4. Tecumseh AEZ1380Y: High-torque domestic compressor.
  5. Secop TLES7.5KK.3: Equivalent displacement for R134a conversion.

Professional Engineering Advice

  1. Cleanliness is Key: When a compressor burns out, it releases acid into the oil. Always replace the filter drier and perform a nitrogen flush.
  2. Match the Displacement: Never go more than 10% lower in cm³ displacement.
  3. Vacuuming: R600a systems are extremely sensitive to moisture. A deep vacuum (below 500 microns) is mandatory.
  4. Safety First: R600a is flammable. Ensure no open flames or sparks are present during the charging process.

Question: If I have a 350-liter fridge, will the ACC HTK70AA work?
Answer: No. A 350-liter refrigerator typically requires the 154W capacity of the Jiaxipera N1113Y (1/6 HP). The ACC HTK70AA (1/8 HP) is designed for smaller units (around 150-220 liters). Using it will lead to continuous running and premature failure.

not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA). mbsmpro
not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA). mbsmpro



Huayi HYB60MGU Compressor 1/7 HP R600a LBP

huayi-hyb60mgu-compressor-1-7-hp-r600a-lbp-mbsmpro

Focus keyphrase: Huayi HYB60MGU Compressor 1/7 HP R600a LBP Technical Specifications Wiring Diagram and Professional Replacement Guide for Domestic Refrigeration Systems

SEO Title: Mbsmpro.com, Compressor, Huayi, HYB60MGU, 1/7 hp, R600a, 110 W, 0.55 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, cooling or freezing

Meta Description: Technical datasheet for the Huayi HYB60MGU compressor. Explore its 1/7 HP capacity, R600a efficiency, electrical wiring schemas, and professional cross-reference replacements.

Slug: huayi-hyb60mgu-compressor-r600a-1-7hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYB60MGU, R600a, 1/7 HP, LBP, Compressor Replacement, EMT45HDR, TLES5.7KK.3, T1112Y, A60CY, ETA60, GL60AA, EMI45HER, TLS5F, B30H

Excerpt: The Huayi HYB60MGU is a high-efficiency hermetic reciprocating compressor specifically engineered for Low Back Pressure (LBP) applications. Operating on the eco-friendly R600a refrigerant, this 1/7 HP unit is a primary component in modern household refrigerators. This guide provides an in-depth technical analysis, electrical wiring configurations, and reliable replacement alternatives for field engineers.


The Engineering Behind the Huayi HYB60MGU: A Technical Standard in R600a Cooling

In the contemporary landscape of domestic refrigeration, the Huayi HYB60MGU represents a cornerstone of energy-efficient design. As a professional who has spent years troubleshooting and installing these units, it is clear that Huayi has optimized the HYB series to meet the rigorous European and international standards for low-temperature performance.

This compressor is a hermetic reciprocating type, designed for Low Back Pressure (LBP) cycles. Its integration of R600a (isobutane) not only aligns with global environmental mandates but also provides superior thermodynamic efficiency compared to legacy R134a systems. For technicians, understanding the mechanical and electrical nuances of the HYB60MGU is essential for ensuring system longevity.

Technical Data Sheet: Huayi HYB60MGU

Feature Specification
Model HYB60MGU
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigerators / Freezers
Oil Type and Quantity Mineral Oil / 180 ml
Horsepower (HP) 1/7 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1 Phase
Cooling Capacity BTU 375 BTU/h (approx. 110 Watts)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 6.0 cm³
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Standard LBP operation)
Capillary Recommendation 0.026″ – 0.028″ ID (Varies by cabinet)
Application Range -35°C to -10°C
Cooling System Static (Natural convection)
Commercial Classification Residential / Household
Amperage (Running) 0.55 A – 0.7 A
LRA (Locked Rotor Amperage) 4.8 A
Type of Relay PTC (Positive Temperature Coefficient)
Capacitor Requirement None (RSIR Configuration)

Electrical Wiring Schema (RSIR Configuration)

The terminal housing of the Huayi HYB60MGU follows a standard triangular pin configuration which is critical for proper startup and protection.

Schema Description:

  • Common (C): The apex pin. This pin connects to the Thermal Overload Protector (OLP), which monitors the motor temperature and current draw.
  • Start (S): The pin usually on the right side. It is momentarily energized by the PTC relay to initiate rotation.
  • Main/Run (M): The pin on the left side. This winding remains energized throughout the operation of the compressor.

Wiring Logic:
Line (Hot) -> Overload Protector -> Common Pin
Neutral -> PTC Relay -> Main Pin & Start Pin

Engineering Note: Always verify the resistance between C-S and C-M. The sum of these two measurements should roughly equal the resistance across S-M. Any significant deviation indicates a winding fault.


Comparative Efficiency: R600a vs. R134a Models

When evaluating the HYB60MGU, it is helpful to compare it against similarly rated R134a compressors to understand the benefits of the modern R600a cycle.

Metric Huayi HYB60MGU (R600a) Standard 1/7 HP (R134a)
Operating Pressure Low / Vacuum High Positive
Displacement 6.0 cm³ 4.5 cm³
Energy Consumption Low (High COP) Moderate
Environment GWP < 3 (Eco-friendly) GWP 1430 (Global Warming)

Professional Replacement Cross-Reference

In repair scenarios where the exact Huayi model is unavailable, these alternatives provide the same cooling capacity and displacement.

5 Replacements in R600a (Same Gas):

  1. Embraco: EMT45HDR (High-reliability alternative)
  2. Secop (Danfoss): TLES5.7KK.3 (Common European replacement)
  3. Jiaxipera: T1112Y (Found in many Beko/Haier units)
  4. Donper: A60CY
  5. Wanbao: ETA60

5 Replacements in R134a (Conversion Required):
Note: Converting from R600a to R134a requires a full system flush and capillary resizing.

  1. Zem: GL60AA
  2. Embraco: EMI 45HER
  3. Secop: TLS5F
  4. Huayi: B30H
  5. Cubigel: GL60AA

Field Engineering Advice and Notices

  • Vacuuming Procedure: Because R600a systems operate at very low pressures, moisture is a catastrophic contaminant. Always pull a vacuum down to at least 200 microns before charging.
  • Charging by Weight: R600a is highly sensitive to overcharging. Always use a digital scale and charge precisely to the manufacturer’s specification (usually 40-60 grams). Do not charge by pressure.
  • Flammability Safety: R600a is isobutane. Ensure no open flames are nearby during charging or discharging. Use “Lokring” cold connections if you are not in a controlled, ventilated environment for brazing.
  • Overload Protection: If the compressor “clicks” but fails to start, check the PTC relay first. These components are prone to cracking due to heat cycles.

Conclusion and Professional Benefit

The Huayi HYB60MGU is a resilient unit that, when maintained correctly, offers years of silent and efficient operation. Its low running amperage makes it an ideal choice for off-grid or solar-powered refrigeration setups where energy conservation is paramount. For the service technician, its standard footprint and predictable electrical behavior make it a preferred model in the field.

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro
Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro



TEE NTU 170 MT Compressor 1/4 HP R600a

tee-ntu-170-mt-compressor-1-4-hp-r600a-mbsmpro

Focus Keyphrase: TEE NTU 170 MT Compressor 1/4 HP R600a Low Back Pressure Technical Specifications and Replacement Guide

SEO Title: Mbsmpro.com, Compressor, NTU 170 MT, 1/4 hp, TEE, Cooling, R600a, 204 W, 0.9 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C

Meta Description: Technical analysis of the TEE NTU 170 MT compressor. Discover 1/4 HP power specs, R600a efficiency, LBP cooling capacity, wiring diagrams, and cross-reference replacement charts.

Slug: compressor-tee-ntu170mt-r600a-1-4-hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, TEE, Turk Elektrik, NTU 170 MT, R600a, 1/4 HP Compressor, LBP, Refrigerator Repair, HVAC Engineering, EMT2121U, HTK12AA, HMK12AA, NT1114Y, HYB12MHU, GL90AA, FFI7.5HAK, NL7F

Excerpt: The TEE NTU 170 MT is a high-efficiency hermetic reciprocating compressor designed for low back pressure applications using R600a refrigerant. Known for its reliability in household refrigeration, this unit operates at 220-240V 50Hz. This article explores its technical specs, cooling capacity, and suitable replacements for HVAC technicians and engineers worldwide.


The Engineering Excellence of the TEE NTU 170 MT: A Deep Dive into R600a Refrigeration

In the evolving world of domestic refrigeration, efficiency and environmental impact are the primary drivers of innovation. The TEE NTU 170 MT, manufactured by Turk Elektrik, stands as a testament to these principles. As a Low Back Pressure (LBP) compressor optimized for R600a (isobutane), this model has become a staple in modern household refrigerators and freezers across Europe and the Middle East.

Understanding the NTU 170 MT Architecture

The NTU 170 MT is engineered to handle the unique thermodynamic properties of R600a. Unlike older R134a systems, R600a operates at lower pressures but requires a larger displacement to achieve comparable cooling capacities. This compressor utilizes a robust motor designed for RSIR (Resistive Start – Inductive Run) operation, ensuring a reliable start even under varying voltage conditions typically found in domestic environments.

The “MT” series is specifically calibrated for high-performance cooling while maintaining a low noise floor. With a Locked Rotor Amperage (LRA) of 14A, it demonstrates significant starting torque, which is essential for overcoming the initial pressures of the refrigeration cycle after a defrost period.

Technical Specification Table

Feature Specification
Model NTU 170 MT
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Deep Cooling
Oil Type and Quantity Mineral Oil (approx. 180 ml)
Horsepower (HP) 1/4 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1Ph
Cooling Capacity BTU ~700 BTU/h (at -23.3°C Evaporating Temp)
Motor Type RSIR
Displacement 11.20 cc
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Low side depending on load)
Capillary Recommendation 0.031″ ID x 3 meters (approximate)
Temperature Function -35°C to -10°C
Cooling System Static (No fan required for compressor)
Commercial Class Domestic / Light Commercial
Amperage (FLA) 0.8 A – 1.0 A
LRA (Locked Rotor) 14 A
Relay Type PTC Starter
Capacitor Not required (RSIR), Optional Run Cap for CSIR conversion

Electrical Wiring Schema (RSIR Configuration)

For field technicians, understanding the terminal configuration is vital. The TEE NTU 170 MT follows the standard triangular pin layout:

  1. Common (C): Top pin (typically connected to the overload protector).
  2. Start (S): Right pin (connected to the PTC relay for starting).
  3. Main/Run (M): Left pin (connected to the neutral line).

Schema Logic:
[Line] -> [Overload Protector] -> [Common Pin]
[Neutral] -> [PTC Relay] -> [Main Pin] & [Start Pin (Momentary)]

Performance Comparison: R600a vs. R134a Equivalents

When comparing the NTU 170 MT to R134a units of similar horsepower, several differences emerge. The R600a model offers a superior Coefficient of Performance (COP).

Metric TEE NTU 170 MT (R600a) Equivalent R134a Model (e.g., GL90AA)
Efficiency (COP) 1.45 – 1.55 W/W 1.20 – 1.35 W/W
Operating Pressure Low / Vacuum High
Eco-Impact GWP 3 (Low) GWP 1430 (High)
Noise Level Very Low Moderate

Compatibility and Replacement Guide

Finding a direct replacement requires matching the displacement and the LBP characteristic. Below are the recommended alternatives for the NTU 170 MT.

Top 5 Replacements (R600a – Same Gas):

  1. Embraco: EMT2121U
  2. Secop (Danfoss): HTK12AA
  3. ACC / Cubigel: HMK12AA
  4. Jiaxipera: NT1114Y
  5. Huayi: HYB12MHU

Top 5 Replacements (R134a – Conversion Required):
Note: Converting from R600a to R134a requires a full system flush, capillary adjustment, and oil compatibility check.

  1. Zem: GL90AA
  2. Embraco: FFI 7.5HAK
  3. Secop: TLES7.5KK.3
  4. Tecumseh: THB1375YSS
  5. Carlyle: S26SC

Engineering Notices and Maintenance Tips

  • Vacuuming Procedure: Due to the hygroscopic nature of the systems and the low pressures of R600a, a deep vacuum (minimum 200 microns) is mandatory. R600a systems are highly sensitive to non-condensables.
  • Charging Safety: R600a is flammable. Always ensure the work area is well-ventilated. Use a dedicated electronic scale, as the charge weight is significantly lower than R134a (often only 40-60 grams).
  • Filter Drier: Always replace the filter drier with one specifically labeled for R600a (XH-9 or equivalent) during any compressor swap.
  • Capillary Blockage: Because R600a operates at lower discharge temperatures, carbonization is rare, but moisture-related ice blockages are common if the system is not perfectly dry.

Benefits for the End-User

Using a TEE NTU 170 MT ensures the refrigerator operates with minimal energy consumption. For the homeowner, this translates to lower electricity bills and a quieter kitchen environment. For the technician, the wide availability of parts for the TEE/Arçelik ecosystem makes it a preferred choice for long-term maintenance.

TEE NTU 170 MT Compressor 1/4 HP R600a mbsmpro
TEE NTU 170 MT Compressor 1/4 HP R600a mbsmpro



Copper Pipe Flaring: Common Mistakes and How to Avoid Them in HVAC and Plumbing Installations

Copper Pipe Flaring: Common Mistakes and How to Avoid Them in HVAC and Plumbing Installations

Improper flaring can lead to refrigerant leaks, system inefficiency, and costly repairs. This guide outlines the most frequent errors and how to engineer flawless connections.

Mbsmpro.com, Copper Pipe, Flaring, HVAC, Plumbing, R600a, Mini-Split, Leak Prevention, Soft Copper, Flaring Block, 1/4″, 3/8″, 1/2″, 5/8″, Refrigerant Line

Understanding Copper Pipe Flaring

Flaring is the process of shaping the end of a copper pipe into a conical form to create a tight seal with flare fittings. It’s widely used in HVAC systems, refrigeration lines, and plumbing to ensure leak-proof connections—especially when working with R600a, R134a, or R410A refrigerants.

Common Mistakes in Copper Pipe Flaring

Mistake Impact Correction
Uneven flare Causes leaks Use calibrated flaring tools
Over-tightening Damages flare face Torque to spec using flare nut wrench
Under-tightening Loose connection Confirm seal with leak detector
Dirty pipe ends Poor seal Clean and deburr before flaring
Wrong pipe size Misfit with flare nut Match pipe with fitting size (e.g., 1/4″, 3/8″)
No lubrication Cracked flare Use flare oil or refrigerant-safe lubricant
Using hard copper Cracks during flaring Use soft copper tubing only

Comparison: Flaring vs. Brazing

Method Seal Quality Ease of Repair Tool Cost Leak Risk
Flaring High (if done right) Easy Low Medium
Brazing Very High Difficult High Low

Flaring is preferred for mini-split systems and field repairs, while brazing is ideal for permanent joints.

Engineering Tips for Perfect Flares

  • Use a flaring block or hydraulic flaring tool for consistent results.
  • Heat the pipe slightly if working in cold environments to prevent cracking.
  • Inspect flare face for concentric rings and smooth finish.
  • Always pressure test after installation to verify seal integrity.

Benefits of Proper Flaring

  • Leak-free connections reduce refrigerant loss and environmental impact.
  • Improved system efficiency due to stable pressure.
  • Longer equipment life with reduced wear on compressors and valves.

Focus Keyphrase

Copper Pipe Flaring Common Mistakes HVAC Plumbing Leak Prevention Soft Copper Mini-Split Refrigerant Line Installation Guide

SEO Title

Mbsmpro.com, Copper Pipe, Flaring, HVAC, Plumbing, R600a, Mini-Split, Leak Prevention, Soft Copper, Flaring Block

Meta Description

Avoid costly leaks and system failures by mastering copper pipe flaring. Learn the most common mistakes in HVAC and plumbing, plus engineering tips for perfect flare connections.

Slug

copper-pipe-flaring-mistakes-hvac-plumbing-guide

Tags

Copper Pipe, Flaring, HVAC, Plumbing, R600a, Mini-Split, Leak Prevention, Soft Copper, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Refrigerant Line, Flaring Block

Excerpt

Copper pipe flaring is essential for leak-free HVAC and plumbing systems. This guide covers common mistakes, engineering tips, and comparisons with brazing to help technicians achieve perfect connections.

Mbmpro-2026-01-08_235817 mbsmpro



Embraco FMXY9C Compressor: R600a, 1/6 HP

Embraco FMXY9C Compressor: R600a, 1/6 HP, Fullmotion Inverter, 220-240V, LBP Cooling – Technical Review and Comparison

This article provides a full technical breakdown of the Embraco FMXY9C compressor, including specs, performance, comparisons, and engineering advice for refrigeration systems.

Mbsmpro.com, Compressor, FMXY9C, Embraco, R600a, 1/6 hp, Cooling, 220-240V, 1Ph 50Hz, LBP, Fullmotion, Inverter, −35°C to −10°C, CE UL, Austria

Overview of Embraco FMXY9C Compressor

The Embraco FMXY9C is a hermetic reciprocating compressor designed for low back pressure (LBP) refrigeration systems. It uses R600a (isobutane) refrigerant, offering high efficiency and low environmental impact. Built in Austria, this model features Fullmotion inverter technology, allowing variable speed operation for optimized cooling and energy savings.

Technical Specifications Table

Parameter Value
Model FMXY9C
Brand Embraco
Refrigerant R600a
Voltage/Frequency 220-240V / 50Hz
Phase Single (1Ph)
Rated Load Amps (RLA) 1.1 A
Locked Rotor Amps (LRA) 1.7 A
HP Rating ~1/6 HP
Cooling Type LBP
Compressor Type Fullmotion (Inverter)
Displacement 8.74 cm³
Max Winding Temp 130°C
Certifications CE, UL
Origin Austria
Oil Type Alkyl Benzene
Application Range −35°C to −10°C

Comparison with Similar Compressors

Model Refrigerant HP Rating Application Voltage Technology
FMXY9C R600a ~1/6 HP LBP 220-240V Fullmotion Inverter
VTH1113Y R600a ~1/6 HP LBP 220-240V Inverter
NEK6210U R290 ~1/5 HP MBP 115V RSIR

FMXY9C offers superior energy control and quieter operation compared to fixed-speed models like NEK6210U.

Engineering Insights & Usage Tips

  • Fullmotion Technology: Adjusts compressor speed based on cooling demand, reducing energy consumption.
  • R600a Refrigerant: Eco-friendly with zero ozone depletion, but flammable—requires sealed systems and proper ventilation.
  • Electronic Protection: Prevents overload and ensures safe operation under voltage fluctuations.
  • Maintenance Advice: Use only Embraco-approved components and compatible oil to maintain performance and warranty.

Benefits of FMXY9C Compressor

  • Energy Efficiency: Variable speed operation reduces power draw.
  • Quiet Performance: Ideal for residential and commercial refrigeration.
  • Durability: Designed for high ambient temperatures and long duty cycles.

Focus Keyphrase

Embraco FMXY9C Compressor R600a 1/6 HP Fullmotion Inverter 220-240V 50Hz LBP Cooling Austria CE UL Specs Comparison

SEO Title

Mbsmpro.com, Compressor, FMXY9C, Embraco, R600a, 1/6 hp, Cooling, 220-240V, 1Ph 50Hz, LBP, Fullmotion

Meta Description

Explore the full specifications of Embraco FMXY9C compressor for refrigeration systems using R600a. Includes technical tables, performance comparisons, and engineering advice for LBP cooling applications.

Slug

embraco-fmxy9c-compressor-r600a-220v-lbp-fullmotion-specs

Tags

Embraco, FMXY9C, R600a, Compressor, Inverter, Fullmotion, LBP, Cooling, 220-240V, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Austria, CE, UL

Excerpt

The Embraco FMXY9C compressor is a high-efficiency inverter model using R600a refrigerant. Designed for LBP applications, it operates on 220-240V and offers quiet, reliable cooling with electronic protection.

Embraco FMXY9C Compressor: R600a, 1/6 HP mbsmpro



Jiaxipera VTH1113Y Compressor: R600a

Jiaxipera VTH1113Y Compressor: R600a, 220-240V, LBP Cooling, Technical Breakdown and Engineering Insights

Jiaxipera VTH1113Y Compressor Horsepower Rating

The Jiaxipera VTH1113Y compressor is typically rated at approximately 1/6 HP (Horsepower). This rating aligns with its application in low back pressure (LBP) systems, such as household refrigerators using R600a refrigerant. The compressor is designed for efficient cooling in temperature ranges from −35°C to −10°C, making it suitable for static cooling environments.

Comparison Table: HP Ratings of Similar Compressors

Model Refrigerant HP Rating Application
VTH1113Y R600a ~1/6 HP LBP
VTX1116Y R600a ~1/5 HP MHBP
VNC1118Z R134a ~1/5 HP HBP

Engineering Insight

  • 1/6 HP compressors are ideal for compact refrigerators and deep freezers.
  • They offer low energy consumption and quiet operation, especially when paired with inverter technology.
  • R600a refrigerant enhances efficiency but requires careful handling due to its flammability.

Copy All for WordPress:

Jiaxipera VTH1113Y Compressor Horsepower Rating

The Jiaxipera VTH1113Y compressor is typically rated at approximately 1/6 HP (Horsepower). This rating aligns with its application in low back pressure (LBP) systems, such as household refrigerators using R600a refrigerant. The compressor is designed for efficient cooling in temperature ranges from −35°C to −10°C, making it suitable for static cooling environments.

Model Refrigerant HP Rating Application
VTH1113Y R600a ~1/6 HP LBP
VTX1116Y R600a ~1/5 HP MHBP
VNC1118Z R134a ~1/5 HP HBP

1/6 HP compressors are ideal for compact refrigerators and deep freezers. They offer low energy consumption and quiet operation, especially when paired with inverter technology. R600a refrigerant enhances efficiency but requires careful handling due to its flammability.

This article explores the Jiaxipera VTH1113Y compressor used in inverter refrigerators, highlighting its specifications, performance, and comparisons with similar models.

Mbsmpro.com, Compressor, VTH1113Y, Jiaxipera, R600a, 220-240V, 1PH, 50Hz, LBP, Static Cooling, −35°C to −10°C, Alkyl Benzene Oil, ASHRAE Standard

Technical Overview of Jiaxipera VTH1113Y Compressor

The Jiaxipera VTH1113Y is a hermetic inverter compressor designed for household refrigerators using R600a (isobutane) refrigerant. It operates on 220-240V at 50Hz, with a single-phase configuration. This model is optimized for Low Back Pressure (LBP) applications, making it ideal for cooling environments ranging from −35°C to −10°C.

Performance Specifications Table

Parameter Value
Refrigerant R600a
Voltage/Frequency 220-240V / 50Hz
Cooling Type Static
Application LBP
Evaporating Temp Range −35°C to −10°C
Displacement 8.9 cm³
Max Winding Temp 130°C
Max Discharge Pressure 0.98 MPa
COP Range 1.60 – 1.72
Power Consumption 40.7W – 131.3W
Current Range 0.44A – 1.25A
Speed Range 1320 – 4500 RPM
Oil Type Alkyl Benzene

Comparison with Similar Compressors

Model Refrigerant HP Rating Application COP Voltage
VTH1113Y R600a ~1/6 HP LBP 1.60–1.72 220-240V
VTX1116Y R600a ~1/5 HP MHBP 1.65–1.75 220-240V
VNC1118Z R134a ~1/5 HP HBP 1.55–1.70 220-240V

VTH1113Y is best suited for low-temperature applications, while VTX1116Y and VNC1118Z serve medium and high pressure systems respectively.

Engineering Insights & Usage Recommendations

  • Use in LBP Systems: Ideal for deep-freezing and low-temperature refrigeration.
  • R600a Compatibility: Environmentally friendly with low GWP, but requires leak-proof systems due to flammability.
  • Voltage Stability: Ensure consistent 220-240V supply to avoid overload protection triggers.
  • Oil Maintenance: Use only Alkyl Benzene oil for optimal lubrication and longevity.

Benefits of VTH1113Y Compressor

  • Energy Efficient: High COP values reduce electricity consumption.
  • Quiet Operation: Inverter technology minimizes noise.
  • Durable Design: Withstands high discharge pressure and ambient temperatures up to 43°C.

Focus Keyphrase

Jiaxipera VTH1113Y Compressor R600a 220-240V 50Hz LBP Cooling Static Inverter Refrigerator Technical Specifications Comparison

SEO Title

Mbsmpro.com, Compressor, VTH1113Y, Jiaxipera, R600a, 220-240V, LBP, Static Cooling, −35°C to −10°C

Meta Description

Explore the full specifications of Jiaxipera VTH1113Y compressor for inverter refrigerators using R600a. Includes technical tables, performance comparisons, and engineering advice for LBP cooling systems.

Slug

jiaxipera-vth1113y-compressor-r600a-220v-lbp-specs

Tags

Jiaxipera, VTH1113Y, R600a, Compressor, Inverter, Refrigerator, LBP, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Cooling, Static, 220-240V

Excerpt

Jiaxipera VTH1113Y is a high-efficiency inverter compressor using R600a refrigerant. Designed for LBP applications, it operates on 220-240V and offers quiet, reliable cooling for household refrigerators.

Jiaxipera VTH1113Y Compressor: R600a mbsmpro



Refrigerants, Standing, Suction and Discharge Pressures for Modern HVAC Systems

refrigerants-standing-suction-and-discharge-pressures-for-modern-hvac-systems-mbsmpro

Guide to Common Refrigerants: Standing, Suction and Discharge Pressures for Modern HVAC Systems

Refrigeration technicians today work with a mix of legacy and new-generation refrigerants, each with its own safe pressure range and boiling temperature. Understanding these values is essential for accurate diagnostics, safe charging and long compressor life in air‑conditioning and commercial refrigeration.


Key role of pressure charts

Pressure–temperature charts and standing/suction/discharge tables give technicians a fast reference for what a system “should” be doing at a given ambient or evaporating temperature.
Using wrong reference values can lead to over‑charging, overheating, liquid slugging or misdiagnosis of a healthy system as faulty.


Overview of common refrigerants

The image groups the most used refrigerants in residential and light commercial systems: R22, R134a, R600a, R32, R290, R407C, R404A, R410A and R417 (R417A).
Each gas has a typical standing pressure (static pressure at rest), an evaporating suction pressure, a condensing discharge pressure and a characteristic boiling point at atmospheric pressure.


Typical pressure ranges from the chart

The following table summarises the indicative values shown in the chart (all pressures are approximate, for normally loaded systems at typical comfort‑cooling conditions).

Indicative pressures and boiling points

Refrigerant Approx. standing pressure Approx. suction pressure Approx. discharge pressure Boiling point (°C) Typical replacement for
R22 150–155 psi / 1034–1069 kPa  60–70 psi / 413–483 kPa  250–300 psi / 1724–2069 kPa  −40.8 °C  R11 / legacy R22 AC 
R134a 80–95 psi / 552–655 kPa  12–15 psi / 83–103 kPa  ~150 psi / 1034 kPa  −26.2 °C  R12 in domestic & auto 
R600a 40–50 psi / 276–345 kPa  ≈0–1 psi / 0–7 kPa  ~150 psi / 1034 kPa  −11.7 °C  Low‑charge fridges, R12 
R32 240–245 psi / 1655–1689 kPa  110–115 psi / 758–793 kPa  175–375 psi / 1207–2586 kPa  −52.0 °C  High‑efficiency R410A/R22 
R290 125–130 psi / 862–896 kPa  65–70 psi / 448–483 kPa  275–300 psi / 1896–2069 kPa  −42.1 °C  R22 in some systems 
R407C 180–185 psi / 1241–1276 kPa  75–80 psi / 517–552 kPa  275–300 psi / 1896–2069 kPa  −45.0 °C (bubble)  R22 retrofits 
R404A 180–185 psi / 1241–1276 kPa  80–90 psi / 552–621 kPa  275–300 psi / 1896–2069 kPa  −46.2 °C  R502 low‑temp systems 
R410A 225–230 psi / 1551–1586 kPa  120–130 psi / 828–896 kPa  450–500 psi / 3103–3447 kPa  −51.4 °C  Modern R22 AC 
R417A ~140 psi / 965 kPa standing  ~65 psi / 448 kPa suction  ~261 psi / 1796 kPa discharge  −39.0 °C  R22 service blend 

These figures are not universal “set‑points”, but practical targets that help technicians decide whether a system is under‑charged, over‑charged or suffering airflow or mechanical problems.


Safety, cylinder colours and replacements

Many countries use conventional cylinder colour codes to identify refrigerants quickly on site, although some regions are migrating to neutral colours with clear labelling.
Hydrocarbons such as R290 and R600a are flammable, so working pressures must always be combined with strict leak‑prevention, ventilation and ignition‑control procedures.

When phasing out ozone‑depleting R22, blends like R407C or R417A are often used in retrofit projects, while new high‑efficiency equipment typically relies on R410A or R32 with different design pressures.
Comparing the standing and operating pressures during commissioning helps ensure that a replacement refrigerant is compatible with existing components such as compressors, valves and heat‑exchangers.


Practical use for technicians and trainers

  • Technicians can laminate similar tables and keep them in the toolbox or on the workshop wall as a quick‑reference during charging and troubleshooting.
  • Training centres and HVAC content creators like Mbsmgroup and Mbsm.pro can turn these values into interactive quizzes, infographics or mobile‑friendly charts for students and new technicians.​
Refrigerants, Standing, Suction and Discharge Pressures for Modern HVAC Systems mbsmpro



Mbsm.pro, Compressor, Lg, Lbp, MB88NA, 151 w, 1/5 hp, r600a, 1ph-220v-50hz

Compressor Specifications:

  1. Model Name: LG LBP MB88NA
    • This is the specific model number of the compressor manufactured by LG.
  2. Power Consumption: 151 W
    • The compressor consumes 151 watts of electrical power during operation. This indicates the energy efficiency of the unit.
  3. Horsepower (HP): 1/5 HP
    • The compressor has a motor rated at 1/5 horsepower , which is equivalent to 0.2 HP . This is a relatively small compressor, typically used in compact refrigeration systems or appliances like mini-fridges or beverage coolers.
  4. Refrigerant Type: R600a
    • R600a (isobutane) is an eco-friendly refrigerant with low global warming potential (GWP). It is commonly used in domestic refrigerators and freezers due to its energy efficiency and minimal environmental impact. However, it is flammable, so proper handling is required.
  5. Electrical Configuration: 1 Phase, 220V, 50Hz
    • The compressor operates on a single-phase power supply with a voltage of 220 volts and a frequency of 50 hertz . This configuration is typical for residential applications in regions like Europe, Asia, and parts of Africa.

Applications:

Given the specifications, this compressor is likely designed for use in low-back pressure (LBP) systems. LBP compressors are typically used in:

  • Household refrigerators
  • Freezers
  • Beverage coolers
  • Compact cooling appliances
https://www.mbsm.pro/wp-content/uploads/2025/04/Mbsm_dot_pro_private_PDF-MB88NA.pdf

The R600a refrigerant further confirms that this compressor is intended for smaller, energy-efficient cooling systems.


Key Considerations:

  1. Environmental Impact:
    • R600a is a hydrocarbon refrigerant, making it environmentally friendly compared to older refrigerants like R134a or R22. However, it requires careful handling due to its flammability.
  2. Voltage Compatibility:
    • Ensure that the power supply matches the compressor’s requirements (220V, 50Hz). Using incompatible voltage can damage the compressor or cause it to malfunction.
  3. System Design:
    • Since this is an LBP compressor, it is optimized for systems with lower evaporating temperatures, such as freezers or deep-freeze applications.

Conclusion:

The LG LBP MB88NA compressor is a compact, energy-efficient unit designed for small-scale refrigeration systems. Its key features include:

  • Low power consumption (151W)
  • Eco-friendly refrigerant (R600a)
  • Compatibility with 220V, 50Hz power supplies
  • Suitable for low-back pressure applications



Mbsm.pro, Compressor, BTF60AA, 1/7 hp, r600a, lbp, Serbian Compressor, serie T, from 180 L to 200 L, from 70 to 75 W

Siberia Compressor Catalogue Overview

The Siberia Compressor Catalogue provides detailed specifications and performance data for various compressor series designed for refrigeration systems. These compressors are available in multiple configurations, including R134a and R600a refrigerants, catering to different cooling capacities and applications. Below is an organized breakdown of the catalog’s key sections:


1. Compressor Series Overview

S Series (Low Back Pressure – LBP)

  • Refrigerants: R600a (High Efficiency), R600a (Medium Efficiency), R134a
  • Applications: Suitable for small to medium-sized refrigerators.
  • Key Features:
    • Compact design
    • Low noise and vibration
    • High reliability

V Series (Low Back Pressure – LBP)

  • Refrigerants: R600a, R134a
  • Applications: Ideal for compact refrigeration units.
  • Key Features:
    • Energy-efficient operation
    • Small footprint
    • Environmentally friendly refrigerants

F Series (Low Back Pressure – LBP)

  • Refrigerants: R134a, R600a
  • Applications: Designed for larger refrigeration systems.
  • Key Features:
    • High cooling capacity
    • Multiple motor types (RSIR/RSCR)
    • Robust performance under varying conditions

T Series (Low Back Pressure – LBP)

  • Refrigerants: R600a, R134a
  • Applications: Versatile use in household and commercial refrigeration.
  • Key Features:
    • Very compact size
    • Low noise and vibration
    • High reliability

2. Performance Specifications

Example: T Series Compressors (R600a)

Model
Power (HP)
Displacement (cm³)
Cooling Capacity (W)
Input Power (W)
Rated Current (A)
COP
Oil Charge (ml)
BTF60AA
1/7
6.0
105
74 / 70
0.52 / 0.40
1.42 / 1.50
180
BTF60AA®
1/7
6.0
105
68 / 64
0.50 / 0.34
1.54 / 1.65
180
BTR60AA©
1/7
6.0
105
66 / 60
0.42 / 0.29
1.60 / 1.75
180

Example: S Series Compressors (R600a)

Model
Displacement (cm³)
Motor Type
Cooling Capacity (W)
Input Power (W)
Rated Current (A)
COP
Oil Charge (ml)
BSR51AA
5.1
RSCR
92
53
0.26
1.75
200
BSR58AA
5.8
RSCR
105
60
0.29
1.75
200
BSR68AA
6.8
RSCR
120
69
0.33
1.75
200

3. Special Requirements for Refrigerants

R134a Compressors

  • The open time of the compressor connection pipe should not exceed 10 minutes .
  • Use dedicated vacuum pumps and charging equipment for R134a.
  • Avoid using organic substances incompatible with R134a in the refrigeration system.
  • Ensure strict control of moisture, impurities, paraffin, silicone oil, and chloride ions.

R600a Compressors

  • Follow safety protocols for hydrocarbon refrigerants during installation and operation.
  • Do not tamper with the pre-filled specialized oil in the compressor.
  • Use appropriate tools and equipment to ensure safe handling of R600a.

4. Refrigerator Size Estimation

The cooling capacity of a compressor determines the refrigerator size it can support. For example:

  • BTF60AA (1/7 HP):
    • Cooling Capacity: 105 W
    • Approximate Refrigerator Size: 157.5 – 210 liters
      • Calculation:

5. Outline Drawings and Packaging

Each compressor model includes detailed outline drawings and packaging specifications. For instance:

  • Packaging Dimensions:
    • Carton Size:
    • Container Capacity: Up to 28 units per container.

6. General Requirements for Installation and Operation

  • Store compressors in a dry, well-ventilated area.
  • Avoid tilting or inverting during transportation.
  • Install within 10 minutes after removing protective plugs.
  • Ensure reliable grounding during operation.
  • Avoid high-voltage or vacuum conditions during startup.

To determine the refrigerator size (in liters) that a 1/7 HP compressor can cool, we need to refer to the performance data of the compressors listed in the provided files. Specifically, the BTF60AA compressor (1/7 HP) is a good reference point for this calculation.

Key Specifications for BTF60AA (1/7 HP):

  • Cooling Capacity: 105 W
  • Refrigerant: R600a
  • Voltage: 220-240V / 50Hz

The cooling capacity of a compressor directly correlates with the volume of the refrigerator it can cool. Typically:

  • 1 W of cooling capacity can cool approximately 1.5 to 2 liters of refrigerator volume.

Calculation:

For the BTF60AA compressor with a cooling capacity of 105 W , the approximate refrigerator volume it can cool is:

Table for 1/7 HP Compressor:

Below is a table summarizing the approximate refrigerator size (in liters) based on the cooling capacity of a 1/7 HP compressor: