Mbsm.pro, Compressor , s36G, 1/10 hp, 1ph 220v/50hz, R134a, 32g, water-cooler, BLY-F/950

| Information | Value |
|---|---|
| Model | BLY-F (905) |
| Rated Voltage | 220-240V~ |
| Rated Frequency | 50/60Hz |
| Heating Power | 450W |
| Total Power | 550W |
| Maximum Rated Wattage of Lamps | 0.5W |
| Cooling Capacity | 1.5L/h |
| Cooling Consumption | 0.100Kwh/H |
| Rated Cooling Current | 0.8A |
| Refrigerant | R134a/32g |
| Climate Class | T |
| Protection Class | I |
| Foam | EPS |
| Waterproof Degree | IPX0 |
| Made in | China |
1. Compressor (Model S36G)
- Purpose: The core component for pressurizing refrigerant in a cooling cycle.
- Model S36G: Likely a specific compressor model (possibly from a brand like Secop, Danfoss, or a regional manufacturer). Verify with manufacturer documentation for exact specs.
- Application: Small-scale systems (e.g., commercial water coolers, medical devices, or compact refrigeration) due to the small refrigerant charge.
2. Refrigerant (R134a, 32g)
- R134a: A common hydrofluorocarbon (HFC) refrigerant used in medium-temperature systems (e.g., refrigerators, AC units, water coolers).
- 32g Charge: Indicates a small system, typical for portable or compact units. Ensure the charge matches manufacturer specifications to avoid inefficiency or damage.
3. Water-Cooler System
- Water-Cooled Condenser: Uses water (instead of air) to dissipate heat, improving efficiency. Requires a water supply, pump, and possibly a cooling tower.
- Applications: Often found in commercial settings (e.g., water dispensers, industrial chillers, or high-efficiency HVAC systems).
4. BLY-F/950
- Likely a component model, such as:
- Filter drier: Removes moisture/contaminants from refrigerant.
- Pressure switch: Safety device to control system pressure.
- Control board/Valve: Part of the system’s electrical or flow regulation.
- Check manufacturer manuals or suppliers for exact function.
Key Considerations
- Compatibility: Ensure the compressor (S36G) is designed for R134a and water-cooled operation.
- Refrigerant Charge: Confirm 32g is correct (undercharging/overcharging affects performance).
- Water Cooling: Check for scale buildup, water flow rate, and pump functionality.
- BLY-F/950 Replacement: Cross-reference with OEM parts or contact the system manufacturer.
Troubleshooting Tips
- Low Cooling Efficiency: Check refrigerant charge, water flow, or condenser cleanliness.
- Component Failure: Test the BLY-F/950 part (e.g., continuity for switches, clogging in filter driers).
- Noise/Leaks: Inspect the compressor and refrierant lines.
-
File Information:
File Name: Mbsm-tn-media-_Compressor-s36G-R134a-32g-water-cooler-BLY-F-950.jpg
File Type: image/jpeg
File Size: 436.6 KB
File Extension: jpgFile Information:
File Name: Mbsm-tn-media-Compressor-s36G-R134a-32g-water-cooler-BLY-F-950.jpg
File Type: image/jpeg
File Size: 435.14 KB
File Extension: jpgFile Information:
File Name: Mbsm-tn-media-Compressor-s36G-R134a-32g-water-cooler-BLY-F-950.jpg
File Type: image/jpeg
File Size: 549.08 KB
File Extension: jpgFile Information:
File Name: Mbsm-tn-media-Compressor-s36G-R134a-32g-water-cooler-BLY-F-950.pdf
File Type: application/pdf
File Size: 296.7 KB
File Extension: pdf