Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide

What Is the Danfoss SLV15CNK?

If you’ve ever opened the back panel of a commercial chest freezer or a light commercial display case and found a compact, brushless compressor with a controller module attached to it, there’s a good chance you were looking at a Danfoss Secop SLV15CNK. This variable-speed hermetic compressor is one of the most widely deployed LBP (Low Back Pressure) units in European and international commercial refrigeration — and for good reason.

Originally built under the Danfoss brand before the compressor division was spun off as Secop GmbH in 2010, the SLV15CNK has carved out a reliable reputation across commercial food retail, light industrial cooling, and even medical cold-chain applications. The unit pictured above — serial reference 561108N4, profile 104H — is the standard 220–240V, 50/60 Hz variant using R290 (propane) refrigerant, one of the most eco-friendly natural refrigerants available today.


Complete Technical Specifications Table

Parameter Value
Model SLV15CNK / SLV15CNK.2
Utilisation (MBP/HBP/LBP) LBP only (Low Back Pressure)
Domain (Freezing/Cooling) Deep Freezing — evap. temp. –40°C to –10°C
Cooling Wattage at –23°C ~446 W (nominal at standard LBP conditions)
Cubic Feet Cooled ~7–10 ft³ (small to medium chest freezer)
Litres Cooled ~200–280 litres
Kcal/h ~383 Kcal/h
TON ~0.127 TON of refrigeration
Oil Type & Quantity Polyolester (POE) — 600 cm³
Horsepower (HP) 5/8 HP (~0.60 HP)
Refrigerant Type R290 (Propane) — max charge 150 g
Power Supply 220–240V / 1Ph / 50–60 Hz (range: 180–254V)
Cooling Capacity BTU ~1521 BTU/h (LBP nominal)
Motor Type Permanent Magnet (TRI — 3-phase inverter driven)
Displacement 15.28 cm³
Winding Material Copper (3-phase windings, resistance ~7.7 Ω at 25°C)
Pression Charge LBP / LST — max condensing temp 55°C (65°C short-term)
Capillary Approx. 3m / Ø0.31 mm (application-dependent — verify with OEM data)
Compatible Refrigerator Models AHT Deep Freezers, light commercial chest freezers, display cases, ice machines, beverage coolers
Temperature Function –40°C to –10°C evaporating; –35°C practical freezer operation
With Fan or Not Yes — F2 fan cooling required (3.0 m/s airflow on compressor & controller)
Commercial or Domestic Commercial (light commercial / food retail)
Amperage in Function Max 4.6 A
LRA (Locked Rotor Amperage) Electronic cut-off (no traditional LRA — inverter-controlled)
Type of Relay No traditional relay — uses 105N46xx Series SLV Electronic Controller
Capacitor No start/run capacitor — inverter-driven (variable speed 2000–4000 RPM)
Country of Origin & Export Manufactured in Slovakia (Secop GmbH) — exported globally: EU, UK, Middle East, North Africa, Australia, Asia

What Makes This Compressor Special?

Variable Speed Technology

Most technicians encounter fixed-speed compressors day in and day out. The SLV15CNK breaks that mold entirely. It’s a variable speed drive (VSD) compressor, meaning its speed adapts continuously between 2000 and 4000 RPM based on thermal demand. The result is dramatically reduced energy consumption during low-load periods, less mechanical wear, and quieter operation — all things that matter enormously in a commercial food retail environment where a freezer runs 24/7, 365 days a year.

R290 — The Natural Refrigerant Advantage

R290 (propane) is not new, but its adoption in commercial compressors has accelerated rapidly in recent years thanks to its near-zero Global Warming Potential (GWP = 3) compared to the synthetic alternatives it replaces. The SLV15CNK uses a maximum charge of just 150 grams, which keeps it below the safety threshold for flammable refrigerant use in occupied spaces. That tiny charge, combined with propane’s excellent thermodynamic properties, means this compressor achieves high efficiency with a very light environmental footprint.

The Controller Dependency

One detail technicians absolutely must not overlook: this compressor will not function without its dedicated SLV electronic controller (105N46xx series). The label on the unit itself clearly states “Only with SLV controller.” This is not a traditional hermetic compressor you can simply wire up to a relay and a capacitor. The controller handles speed regulation, current protection, speed monitoring, and thermal protection all in one unit. Replacing or sourcing this controller is as important as finding the compressor itself.

Fan Cooling Is Mandatory

At all ambient conditions (32°C, 38°C, and 43°C), the datasheet specifies F2 cooling — meaning fan airflow of at least 3.0 m/s directly on both the compressor body and the electronic controller unit. Attempting to run this compressor without proper forced airflow will trigger thermal protection and lead to premature failure. This is a common oversight when installers replace the compressor without checking the cabinet’s fan arrangement.


Replacement Compressors — Same Gas (R290)

When the SLV15CNK reaches end of life or fails, the most straightforward replacements use the same R290 refrigerant. Here are five proven options:

# Replacement Model Brand Notes
1 SLV15CNK.2 (104H8541) Secop/Danfoss Direct drop-in replacement — latest revision
2 SLV12CNK.2 Secop/Danfoss Slightly lower displacement, same gas and controller family
3 SLV20CNK.2 Secop/Danfoss Higher capacity option — same R290/controller platform
4 NLV14CNK Secop/Danfoss Fixed-speed variant on R290 LBP — requires relay/capacitor
5 SCM10CNX.2 Secop R290, standard hermetic, LBP — no inverter controller needed

Replacement Compressors — Different Refrigerant

If R290 is not available in your region, or if you’re retro-fitting an older system, here are five equivalents using alternative refrigerants with comparable capacity:

# Replacement Model Brand Refrigerant Notes
1 SC15G Secop/Danfoss R404A / R507A Classic LBP hermetic, no controller needed
2 NL11MF Secop/Danfoss R134a LBP/MBP, standard hermetic
3 CAJ9513Z Embraco R404A Direct LBP replacement at similar capacity
4 NEBL2134Z Embraco R600a For domestic/light LBP applications
5 MTZ32-4VM Danfoss R452A/R404A Slightly oversized but compatible for retrofits

⚠️ Important: Switching refrigerants requires changing the oil type, capillary tube, and verifying all safety certifications. Always consult the system manufacturer before cross-refrigerant replacement.


Typical Applications — Which Freezers Use This Compressor?

The SLV15CNK is the heart of many products you’ll recognize from the supermarket floor:

  • AHT Australian series chest freezers (confirmed via MBSM documentation)
  • Light commercial open-top island freezers
  • Vertical display freezer cabinets (small commercial)
  • Beverage coolers with sub-zero requirements
  • Frozen food display cases at petrol stations and convenience stores
  • Ice cream chest cabinets in retail environments

The AHT connection is particularly well-documented — AHT is a major manufacturer of commercial freezers widely deployed across European and African retail chains, and the SLV15CNK is one of their standard compressor choices.


Installation & Service Notes

A few practical points every technician should keep in mind when working with this unit:

Controller wiring: Always refer to the 105N46xx wiring diagram. Polarity and signal connections matter — the controller is not interchangeable between all SLV variants.

Refrigerant handling: R290 is flammable (Class A3). Work in ventilated areas, avoid open flames, and use an R290-certified manifold gauge set. The 150g charge limit means leaks are rare but must be taken seriously.

Oil compatibility: POE oil is mandatory with R290 in this application. Do not substitute mineral oil or alkylbenzene — POE is pre-filled at the factory at 600 cm³.

Mounting vibration: The compressor ships with rubber mounting grommets. Always re-use or replace them — running on a hard mount increases noise and mechanical fatigue.

Capillary tube: The reference capillary for AHT applications is approximately 3m / 0.31mm diameter, but always measure and verify against the original system before cutting new tubing.


Why This Compressor Matters in 2025 and Beyond

The refrigeration industry is at a turning point. Synthetic refrigerants with high GWP are being phased out under F-Gas regulations in Europe and similar legislation worldwide. The SLV15CNK — running on propane with a permanent magnet variable-speed motor — represents exactly the direction the industry is heading: natural refrigerants, intelligent speed control, and reduced energy consumption without compromising reliability.

For service technicians, understanding this platform deeply isn’t just useful today — it’s preparation for the next decade of commercial refrigeration work.




Mbsm.pro, Danfoss, sc15g, compressor, sc15gx, 104g8525, GP14TB, CAJ4452Y, GP14PB, GP14PT, sc15g, 104g 8525, 3/8 hp++, lbp/hbp, 1/2 hp–, 424 W

Danfoss Secop SC15G, SC15GX, 104G8525 compressor, LBP / HBP-R134a, 220-240V/1/50/60/ Hz, displacement 15.28 cc, motor type CSIR
Danfoss Secop SC15G, SC15GX, 104G8525 compressor, LBP / HBP – R134a, 220-240V/1/50/60/ Hz, 15.28 cm3 discharge, CSIR type motor, POE type oil, 550 cm3 oil charge, 230 W at- 25 / 55° C, LRA 14.8 A, maximum refrigerant charge 1300 g, height: 209 mm, weight 13.1 kg

Refrigerant:
R134a
Power Range (W):
201 – 300W 401 – 500W
Performance range (C):
-35C to +15C
Work zone:
PSL RAP
Type of design:
Hermetic
Model series:
CS
Power source:
230V
Type of oil:
POE
Type of engine:
CSIR
Item Condition:
New
Info:
Filled with oil
Shipping Weight:
15,10kg
Content:
1.00 Pieces
Dimensions (Height):
20,90cm
customs tariff number:
84143081
Cooling capacity requirement:
T0 -15 °C
Maker:
Danfoss Purpose
Model:
SC15G
Model Name:
104L8520
Model name 3:
SC15GX
Stroke volume (cm3):
15,28
Performance requirement:
-25 / +55 °C
Power (W):
230
Cooling capacity (W):
424
Max. Starting current (A):
14,8
Type of engine:
CSIR
Note:
Maximum amount of refrigerant 1300 g
Oil quantity (l):
0,55
Compressor type:
Piston
Power range:
-35C to +15C
Alternative:
GP14TB, CAJ4452Y, GP14PB, GP14PT



Danfoss, secop, refrigerator, compressor, SC15G, 104G8520, R134a, 3/8HP, 1ph/220V-240/50HZ

3/8HP Danfoss secop refrigerator compressor SC15G 104G8520 for R134a 

Main features:

1. Adopt high efficient rotary compressor and Japan made motors,

 save power 10% or above.

2. The horizontal designed series can save much space.

3. Optimized design can be tightly built inside the equipment, 

which can save installation time and labor cost.

4. Widely used in freezing storage, cold room, automatic 

vendor machine, cold tanks on the ship, etc. as well as 
in the home use, commercial, refrigerator,

 refrigeration machine, dehumidifier,

 low-temperature laboratory device and some special refrigeration equipment.
 

Available models and details for secop comrpessor:

Model Gas Qty/pallet HP Voltage Code Details
SC10C R22 80 1/3 1ph/220V-240/50HZ 104L2516 MLBP HST
SC12C R22 80 3/8 1ph/220-240V/50HZ 104L2674 MLBP HST
SC15CM R22 80 1/2 1ph/220V-240V/50HZ 104L2848 MLBP HST
SC18CM R22 80 5/8 1ph/220-240V/50HZ 104L2120 MLBP HST
SC10D  R22 80 3/8 1ph/220-240V/50HZ 104L2529 MHBP HST
SC12D R22 80 1/2 1ph/220-240V/50HZ 104L2694 MHBP HST
SC15D R22 80 5/8 1ph/220-240V/50HZ 104L2859 MHBP HST
SC10CL R404A 80 1/3 1ph/220-240V/50HZ 104L2523 LMBP HST
SC12CL R404A 80 3/8 1ph/220-240V/50HZ 104L2623 LMBP HST
SC15CL R404a 80 1/2 1ph/220-240V/50HZ 104L2853 LMBP HST
SC18CL R404a 80 5/8 1ph/220V-240V/50HZ 104L2123 LMBP HST
SC21CL R404a 80 7/8 1ph/220-240V/50HZ 104L2322 LBP HST
SC10G R134a 80 5/16 1ph/220-240V/50HZ 104G8000 LMHBP HST
SC12G R134a 80 1/3 1ph/220-240V/50HZ 104G8240 LMHBP HST
SC15G R134a 80 3/8 1ph/220V-240V/50HZ 104G8520 LMHBP HST
SC18G  R134a 80 1/2 1ph/220-240V/50HZ 104G8820 LMHBP HST
SC21G  R134a 80 5/8 1ph/220-240V/50HZ 104G8140 LMHBP HST



FR6B, Compressor, 103U2654, FR6B 103U2654, DANFOSS TL, FR and SC Hermetic Compressors, DANFOSS, Kiriazi, 343L, 1/5 Hp, MBP, R12, 280g, équivalence, 1/4Hp, R134A, 190g

Compresseurs hermétiques DANFOSS TL, FR et SC

BOC partie
No.

Code Danfoss
Puissance nominale
et
applic
Refrig.
Capacité nominale
(watts)
Réf
. BOC

Code Danfoss
Puissance nominale
et
applic
Réfrigérer
Capacité nominale
(watts)
FR6B 103U2654 1/5 MBP R12 354 TL3F 102G4300 1/10 LBP R134a 58
FR8.5B 103U2854 1/4 MBP R12 450 TL4F 102G4400 1/8 LBP R134a 84
SC10B * 104L2510 1/3 MBP R12 588 TLS5F 102G4520 1/6 LBP R134a 127
FR11B 103U2154 1/3 MBP R12 624 TLS7F 102G4720 1/5 LBP R134a 162
SC12B * 104L2670 4/9 MBP R12 756 NL7F 105G6706 1/4 LBP R134a 183
SC15B * 104L2830 1/2 MBP (LBP) R12 (R502) 912 (768) NL9F ** 105G6802 1/4 LBP R134a 214
SC18B * 1042110 2/3 MBP (LBP) R12 (R502) 1044 (900) NL11F ** 105G6910 1/4 LBP R134a 274
SC21B 104L2310 3/4 MBP R12 1212 SC15F ** 104G8500 1/3 LBP R134a 319
SC10B 104L2510 1/3 LBP R502 468 SC18F ** 104G8800 4/9 LBP R134a 395
SC12B 104L2670 4/9 LBP R502 612 TL3G 104G4350 1/8 MBP R134a 175
SC15C 104L2832 2/3 LBP R502 768 TL4G 102G4452 1/6 MBP R134a 215
SC18C 104L2111 3/4 LBP R502 900 FR6G 103G6660 1/5 MBP R134a 351
SC10G 104G8000 1/3 MBP R134a 591 FR8.5G 103G6780 1/4 MBP R134a 468
SC12G 104G8240 4/9 MBP R134a 751 FR11G 103G6980 1/3 MBP R134a 609
SC18G 104G8820 2/3 MBP R134a 1059 SC15G 104G8520 1/2 MBP R134a 892
SC21G 104G8140 3/4 MBP R134a 1256 SC10CL 104L2523 1/3 MBP R507 450
SC12CL 104L2623 4/9 LBP R507 624 SC15CL 104L2853 2/3 LBP R507 758
SC18CL 104L2123 3/4 LBP R507 893          

 

Remarque:

  1. Les compresseurs marqués ** sont équipés de raccords de refroidisseur d’huile.
  2. Les compresseurs marqués * peuvent être utilisés sur les systèmes R502 avec fonctionnement à tube capillaire dans la gamme LBP.
  3. (Systèmes sans dégivrage automatique uniquement).

Capacités nominales basées sur:

LBP = -23,3 ° C température d’évaporation
MBP = -5 ° C température d’évaporation

 

Relais de remplacement (appareil de démarrage)

Réf
. BOC

Convient au
modèle de compresseur

103N0011 TL3A à TL5A,
FR7.5A à FR11A
103N0002 SC12A, SC15A

 

 




Compresseur, Danfoss, SC15G, R134a, 1/2HP, 50/60Hz

Données techniques

  • Modèle: SC15G
  • Gaz: R-134a
  • Température/Pression: Moyenne / Haute
  • Puissance: 1/2 HP
  • Voltage: 230 V
  • Type De Courant: Monophasé
  • Fréquence: 50/60 Hz
  • Type De Compresseur: Hermétique
  • Décalage: 15.28 cm³
  • Cons.Énergie -25ºC: 233 W
  • Cons.Énergie -10ºC: 440 W
  • Cons.Énergie -5ºC: 497 W
  • Cons.Énergie 0ºC: 549 W
  • Cons.Énergie +5ºC: 595 W
  • Cons.Énergie +7,2ºC: 613 W
  • T° De Condensation: 55 °C
  • Capacidad Frigorífica -25°C: 175 Kcal/h
  • Capacidad Frigorífica -20°C: 308 Kcal/h
  • Capacidad Frigorífica -15°C: 450 Kcal/h
  • Capacidad Frigorífica -10°C: 604 Kcal/h
  • Capacidad Frigorífica -5°C: 775 Kcal/h
  • Capacidad Frigorífica 0°C: 966 Kcal/h
  • Capacidad Frigorífica 5°C: 1184 Kcal/h
  • Capacidad Frigorífica 7.2°C: 1289 Kcal/h
  • Capacidad Frigorífica 10°C: 1431 Kcal/h
  • Tipo Test: Ashare 32