TOSOT TS-H246JAL3

Electrical Schematic & Connection Guide

Since this is a single-phase ($1\phi$) unit, the electrical system relies on a Permanent Split Capacitor (PSC) motor. Below is the technical breakdown of the wiring logic for this 2-ton TOSOT unit:

  • Compressor Wiring: * Common (C): Connects directly to the Overload Protector (Internal).

    • Start (S): Connects to one side of the 50 $\mu$F Capacitor.
    • Run (R): Connects to the Neutral line and the other side of the capacitor.

  • Outdoor Fan Motor: Usually wired in parallel with the compressor power supply, using its own smaller capacitor (typically 5-7 $\mu$F).

Technical Article: TOSOT TS-H246JAL3 Lord Series Analysis

Focus Keyphrase: TOSOT TS-H246JAL3 2 Ton Compressor Specifications and R22 Engineering Guide

SEO Title: Mbsm.pro, TOSOT TS-H246JAL3, 2 Tons, 24000 BTU, R22, 220V, Lord Series Outdoor Unit

Meta Description: Technical deep-dive into the TOSOT TS-H246JAL3 2-ton outdoor unit. Features 23,500 BTU cooling, T3 tropical climate rating, and professional R22 compressor replacement data for HVAC engineers.

Slug: tosot-ts-h246jal3-2-ton-compressor-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, TOSOT, TS-H246JAL3, 2 Ton AC, 24000 BTU, R22 Refrigerant, T3 Tropical Compressor, Panasonic 2K28 replacement, Samsung PH41 replacement.

Excerpt: The TOSOT TS-H246JAL3 is a high-performance 2-ton outdoor air conditioning unit from the Lord Series, specifically engineered for T3 tropical environments. Delivering 23,500 BTU/h of cooling power, this R22-based system is a staple for technicians requiring reliability in extreme heat. This article provides full technical specifications and professional cross-reference guides.


Professional Specification Table

Model Parameter Technical Data
Model TS-H246JAL3
Tonnage 2 Tons
Utilization HBP (High Back Pressure)
Domaine Cooling & Heating (Heat Pump)
Oil Type Mineral Oil (SUNISO 4GS or equivalent)
Horsepower (HP) 2 HP
Refrigerant Type R22
Refrigerant Charge 1.8 Kg
Power Supply 220-240V / 50Hz / $1\phi$
Cooling Capacity 23,500 BTU/h
Heating Capacity 24,000 BTU/h
Motor Type PSC (Permanent Split Capacitor)
Climate Type T3 (Tropical – Up to 52°C)
Running Amperage 10.0 A (Cooling)
LRA (Locked Rotor) 52 A
Capacitor Value 50 $\mu$F / 450V

Performance Comparison: R22 vs. R410A (2-Ton Class)

In the field, the TS-H246JAL3 uses R22, which offers distinct operational differences compared to modern R410A units of the same tonnage.

Feature TOSOT TS-H246JAL3 (R22) Standard 2-Ton (R410A)
Operating Pressure (Suction) 65 – 75 PSI 115 – 130 PSI
Discharge Temperature Moderate High
Compression Ratio Lower (Longer Life) Higher
Oil Sensitivity Low (Mineral) High (POE – Hygroscopic)

Professional Replacement Cross-Reference

If the compressor fails, these models are the gold standard for direct replacement without modifying the chassis:

5 Direct R22 Replacements

  1. Panasonic: 2K28C225A (Industry Standard)
  2. Samsung: PH41VP-ET
  3. LG: QP442PED
  4. Highly: 203DH-32C2
  5. Mitsubishi: RH313VAGT

5 Alternative Replacements (Conversion Required)

  1. GMCC: PA240M2C-4FT (R410A)
  2. Gree: QXF-B239zH070 (R410A)
  3. Panasonic: 5RS092DAA (R410A)
  4. Copeland: ZP24K5E (R410A Scroll)
  5. Tecumseh: RK5515E (R22/R407C)

Engineer’s Notice & Field Advice

  • T3 Climate Advantage: This unit is rated for T3. As an expert, I recommend ensuring the outdoor unit has at least 50cm of clearance from any wall. T3 units move a massive amount of heat; restricting airflow will cause the amperage to spike above the rated 10A, leading to premature winding failure.
  • Capacitor Maintenance: The 50 $\mu$F capacitor is the most common point of failure. If the compressor hums but doesn’t start (drawing high LRA), check the capacitor before condemning the compressor.
  • Charging by Weight: Since the system uses 1.8 Kg of R22, always charge using a digital scale. Overcharging an R22 system in a T3 environment causes liquid slugging and destroys the valve plates.



Mbsm.pro, Copeland Compressor RS80C1E-CAZ-252, 1 HP, R134a Refrigerant, 220-240V Single Phase 50Hz, RSIR Motor, LBP Low Temperature Freezing Application, Hermetic Reciprocating Technology

The Copeland RS80C1E-CAZ-252 represents a specialized hermetic reciprocating compressor engineered for low-temperature refrigeration applications where reliability meets efficiency. This single-phase unit operates on R134a refrigerant and delivers consistent performance in demanding freezing environments ranging from -30°C to -10°C evaporating temperatures.

Technical Overview and Application Domain

The RS80C1E-CAZ-252 belongs to Copeland’s proven RS series of hermetic reciprocating compressors, designed specifically for commercial refrigeration applications requiring low back pressure operation. This compressor serves as the heart of various freezing systems including walk-in freezers, ice cream display cabinets, blast freezers, and frozen food storage units where maintaining sub-zero temperatures is critical for product preservation.

Operating at 220-240V single-phase 50Hz power supply, this unit draws approximately 5 amperes during normal operation, making it suitable for standard commercial electrical systems. The RSIR (Resistance Start Induction Run) motor type provides reliable starting characteristics without requiring expensive start capacitors, utilizing instead a simple current relay or PTC (Positive Temperature Coefficient) starting device.

Core Performance Characteristics

This 1 horsepower compressor generates approximately 8,000 BTU/hr cooling capacity when operating at standard LBP (Low Back Pressure) conditions. The displacement volume typically measures around 10.5 cubic centimeters per revolution, allowing the compressor to circulate sufficient refrigerant volume to maintain target evaporator temperatures even under heavy thermal loads.

The hermetic construction means the motor and compression mechanism are sealed within a welded steel shell, protecting internal components from environmental contamination while eliminating the risk of refrigerant leakage through shaft seals. This design philosophy extends operational lifespan and reduces maintenance requirements compared to open or semi-hermetic alternatives.

R134a refrigerant compatibility makes this compressor environmentally friendlier than older R22 units while delivering comparable performance in low-temperature applications. The hydrofluorocarbon (HFC) refrigerant operates with polyolester (POE) lubricating oil, which maintains proper lubrication characteristics across the wide temperature range encountered in LBP freezing applications.

Motor Design and Electrical Configuration

The RSIR motor configuration employs both main (run) and auxiliary (start) windings within the stator assembly. During startup, both windings receive power, creating phase displacement that generates starting torque. Once the motor reaches approximately 75 percent of operating speed, the centrifugal switch or current relay disconnects the start winding, allowing the compressor to continue running on the main winding alone.

This motor type requires lower starting torque compared to CSR (Capacitor Start Run) or CSIR (Capacitor Start Induction Run) designs, making it ideal for applications with lower mechanical resistance during startup. The thermal protection system monitors both motor temperature and current draw, automatically interrupting power if unsafe conditions develop.

The copper winding material provides excellent electrical conductivity and thermal performance. Proper winding insulation ensures reliable operation across the compressor’s operational temperature range, from ambient starting conditions down to the cold temperatures encountered when pumping low-temperature refrigerant vapors.

Refrigeration System Integration

When integrated into complete refrigeration systems, the RS80C1E-CAZ-252 typically connects to evaporator coils operating between -30°C and -10°C saturated suction temperature. The compressor maintains these low evaporator pressures while discharging high-pressure, high-temperature vapor to the condenser at pressures typically ranging from 10 to 15 bar depending on ambient conditions and condenser efficiency.

Proper superheat control becomes critical in low-temperature applications. Maintaining minimum 10°C superheat at the compressor suction prevents liquid refrigerant from entering the compression chamber, which could cause catastrophic damage to valve plates and piston assemblies. Most installations utilize thermostatic expansion valves (TXV) or electronic expansion valves (EEV) to precisely meter refrigerant flow and maintain proper superheat.

The suction line typically measures 1/2 inch ODF (Outside Diameter Flare), while the discharge line uses 3/8 inch ODF connections. Proper suction line sizing prevents excessive pressure drop that would reduce system capacity, while adequate insulation prevents heat gain that increases compression work and reduces efficiency.

Oil Management and Lubrication

The RS80C1E-CAZ-252 ships from the factory charged with approximately 400-450 milliliters of polyolester lubricating oil. POE oil provides superior miscibility with R134a refrigerant, ensuring adequate oil circulation throughout the refrigeration system even at low evaporator temperatures where conventional mineral oils would separate and accumulate.

In low-temperature applications, proper oil return becomes paramount. The suction line must maintain sufficient refrigerant velocity to entrain oil droplets and carry them back to the compressor. Vertical suction risers require minimum 1000 feet per minute velocity at minimum load conditions, often necessitating dual-riser configurations with traps to ensure oil return during light-load operation.

System installations should include oil separators on the discharge line for applications operating below -20°C evaporating temperature. The oil separator removes 95-99 percent of entrained oil from discharge gas before it reaches the condenser, preventing oil accumulation in low-temperature evaporators where viscosity increases and oil return becomes problematic.

Installation Best Practices

Mounting the compressor requires rigid support capable of handling vibration loads during operation. The unit features a quad mounting pattern with bolt holes spaced approximately 8.0 inches by 4.8 inches, standard for this compressor frame size. Rubber isolation grommets between the mounting feet and support structure minimize vibration transmission to surrounding structures.

Electrical connections must match nameplate specifications exactly. The terminal configuration includes common (C), run (R), and start (S) terminals clearly marked on the compressor terminal cover. Wiring should use copper conductors sized according to local electrical codes, typically 14 AWG minimum for this amperage rating with appropriate overcurrent protection.

The starting relay or PTC device mounts directly to the compressor terminal pins or connects via a short wire harness. Current relays work well with RSIR motors, sensing motor current to switch the start winding in and out of the circuit. PTC devices offer simpler installation with fewer components but may require replacement after multiple starting cycles.

Refrigerant Charging Procedures

Initial system evacuation must reach 500 microns or lower before refrigerant charging begins. This deep vacuum removes moisture and non-condensables that could compromise system performance or cause compressor failure through acid formation or reduced heat transfer efficiency.

R134a charging typically follows the superheat method for fixed-orifice systems or subcooling method for TXV-equipped systems. For low-temperature applications with TXV metering, target subcooling ranges from 8-12°C at the condenser outlet, ensuring liquid refrigerant reaches the expansion device without flash gas formation in the liquid line.

Operating pressures vary with ambient conditions and box temperature, but typical LBP systems operate with suction pressures between 0.5-2.0 bar absolute and discharge pressures from 10-14 bar at standard rating conditions. Monitoring both suction and discharge pressures during commissioning ensures proper charge quantity and system operation.

Performance Optimization

Maximizing compressor efficiency requires attention to several system parameters. Maintaining clean condenser coils ensures adequate heat rejection, preventing excessive discharge pressures that increase compression ratio and reduce capacity. Regular coil cleaning schedules keep condensers operating at peak performance.

Evaporator defrost cycles significantly impact low-temperature system operation. Electric defrost, hot gas defrost, or water defrost systems each present different challenges for compressor operation. Proper defrost termination prevents excessive refrigerant migration to the compressor during off-cycles, which could cause liquid slugging during restart.

Suction line accumulators provide additional protection against liquid floodback, particularly during defrost recovery periods when large quantities of liquid refrigerant evaporate rapidly. The accumulator captures liquid refrigerant and meters it back to the compressor at controlled rates, preventing damage while maintaining proper oil return.

Diagnostic Procedures

Monitoring amperage draw provides valuable diagnostic information. Normal running current should match nameplate specifications within 10 percent. Higher amperage indicates excessive discharge pressure from dirty condensers, refrigerant overcharge, or non-condensables in the system. Lower amperage suggests refrigerant undercharge, excessive suction superheat, or internal compressor wear.

Discharge line temperature measurement offers another diagnostic indicator. Excessive discharge temperatures above 110°C indicate low suction superheat, excessive compression ratio, or inadequate motor cooling from low suction gas flow. Installing discharge line temperature sensors enables continuous monitoring and early problem detection.

Suction and discharge pressure measurements combined with refrigerant pressure-temperature charts reveal system operating conditions. Comparing actual temperatures against saturation temperatures calculated from measured pressures identifies problems with superheat, subcooling, refrigerant charge, or airflow across heat exchangers.

Maintenance Requirements

Hermetic compressors require minimal routine maintenance compared to semi-hermetic or open designs. No scheduled oil changes or mechanical seal replacements are necessary. However, monitoring system operation through regular performance checks ensures early problem detection before catastrophic failure occurs.

Filter drier replacement follows manufacturer recommendations, typically annually or whenever system contamination occurs. Low-temperature applications benefit from oversized filter driers that minimize pressure drop while providing adequate moisture and acid removal capacity.

Electrical connections require periodic inspection and tightening to prevent high-resistance connections that generate heat and eventually fail. Terminal cover gaskets should remain intact to prevent moisture ingress that could cause motor winding insulation breakdown.

Troubleshooting Common Issues

Compressor short cycling often results from low refrigerant charge, dirty evaporator coils restricting airflow, or improperly sized thermal overload protection. Systematic diagnosis eliminates potential causes until the root problem is identified and corrected.

Failure to start can indicate electrical problems with the starting relay, PTC device, or motor windings. Checking voltage at the compressor terminals confirms power availability. Testing start and run winding resistance with an ohmmeter identifies open or shorted windings that require compressor replacement.

Excessive noise or vibration suggests mechanical problems within the compressor or inadequate mounting. Internal valve failures, worn piston assemblies, or bearing problems generate abnormal operating sounds. Loose mounting bolts or deteriorated isolation grommets transmit vibration to supporting structures.

Replacement and Cross-Reference Options

When replacement becomes necessary, several equivalent compressor models offer similar performance characteristics. Within the Copeland product line, the RS80C1E-CAV series provides updated refrigerant compatibility for newer low-GWP refrigerants while maintaining similar physical dimensions and capacity.

Environmental Considerations

R134a refrigerant, while significantly better than older CFC and HCFC refrigerants, still carries a global warming potential of 1430. Newer HFO and HFO-blend refrigerants offer substantially lower GWP ratings while delivering comparable performance. Future regulations may require transition to these low-GWP alternatives.

Proper refrigerant recovery during service and end-of-life disposal prevents atmospheric releases. Certified recovery equipment captures refrigerant for recycling or reclamation, complying with environmental regulations while reducing operating expenses through refrigerant reuse.

Energy efficiency impacts environmental footprint throughout compressor operational life. Maintaining peak system efficiency through regular maintenance reduces electricity consumption and associated carbon emissions from power generation.

Safety Considerations

High-pressure refrigeration systems present several safety hazards. Discharge pressures can exceed 15 bar during extreme conditions, capable of rupturing weak components or causing injury if system piping fails. Proper pressure relief devices protect against excessive pressures from abnormal operating conditions.

Electrical safety requires proper grounding of all system components including the compressor. Ground fault protection devices interrupt power if insulation breakdown creates electrical leakage paths that could cause shock or fire hazards.

Refrigerant safety depends on proper handling procedures. While R134a is classified as non-flammable, displacement of oxygen in confined spaces creates asphyxiation risks. Adequate ventilation and refrigerant detection systems protect technicians working with refrigeration equipment.

Advanced System Integration

Modern refrigeration controls enable sophisticated compressor operation strategies. Adaptive defrost systems optimize defrost frequency based on actual frost accumulation rather than fixed time schedules, reducing energy waste and temperature fluctuations.

Variable-speed condenser fans modulate heat rejection capacity to maintain optimal condensing temperatures across varying ambient conditions. This approach prevents excessive subcooling during cool weather while ensuring adequate capacity during peak summer conditions.

Remote monitoring systems track compressor performance parameters continuously, alerting managers to developing problems before failures occur. Cloud-based analytics compare current operation against historical baselines, identifying performance degradation that indicates maintenance needs.

Economic Analysis

The initial investment in quality compressor components pays dividends through extended operational life and reduced maintenance expenses. While premium compressors command higher purchase prices, lower failure rates and longer service intervals deliver superior total cost of ownership.

Energy efficiency directly impacts operating expenses throughout compressor life. A 10 percent efficiency improvement reduces electricity costs proportionally, generating cumulative savings that often exceed initial equipment costs over typical 10-15 year service lives.

Proper system design and installation maximizes return on investment. Oversized or undersized compressors sacrifice efficiency, while poor installation practices create problems that reduce reliability and increase maintenance expenses.


Complete Technical Specifications Table

Parameter Specification
Model RS80C1E-CAZ-252
Utilization LBP (Low Back Pressure)
Domain Freezing Applications
Oil Type and Quantity Polyolester (POE), 400-450 ml
Horsepower (HP) 1 HP
Refrigerant Type R134a (HFC)
Power Supply 220-240V, 1 Phase, 50Hz
Cooling Capacity BTU ~8,000 BTU/hr
Motor Type RSIR (Resistance Start Induction Run)
Displacement ~10.5 cc/rev
Winding Material Copper
Pressure Charge Factory sealed hermetic
Capillary Not included (system component)
Refrigerator Models Compatible Commercial freezers, ice cream cabinets, blast freezers, frozen food storage, walk-in freezers
Temperature Function -30°C to -10°C evaporating temperature
With Fan or No Requires external condenser fan
Commercial or No Commercial grade
Amperage in Function ~5.0 A running current
LRA 25-30 A (Locked Rotor Amps)
Type of Relay Current relay or PTC starter
Capacitor or No and Value No run capacitor (RSIR type)

Compressor Replacement Options – Same Refrigerant (R134a)

Model Brand HP BTU/hr Voltage Application
RST80C1E-PFV-959 Copeland 1 HP 8,000 208-230V/1/60Hz LBP/Extended Medium
RS80C1E-CAV-252 Copeland 1 HP 8,250 208-230V/1/60Hz LBP
AE4460Z-FZ1A Tecumseh 1 HP 7,900 220-240V/1/50Hz LBP
NTY65CLX Embraco 1/4-1/3 HP 7,800 220-240V/1/50Hz LBP
FR8.5G Danfoss 1 HP 8,100 220-240V/1/50Hz LBP

Compressor Replacement Options – Alternative Refrigerants

Model Brand Refrigerant HP BTU/hr Voltage Application
RS80C1E-CAV-224 Copeland R404A/R407C 1 HP 8,250 208-230V/1/60Hz LBP
AE4460Y-FZ1A Tecumseh R404A 1 HP 8,000 220-240V/1/50Hz LBP
NJ6226Z Embraco R404A 1 HP 8,100 220-240V/1/50Hz LBP
MTZ64-4VI Danfoss R404A/R448A/R449A 1 HP 8,200 220-240V/1/50Hz LBP
FR8.5CL Danfoss R407C 1 HP 7,950 220-240V/1/50Hz LBP

Comparative Performance Analysis

Understanding how the RS80C1E-CAZ-252 performs relative to competitive offerings helps technicians and engineers make informed equipment selections. The comparison table below highlights key performance differences:

Feature Copeland RS80 Tecumseh AE4460Z Embraco NTY65 Danfoss FR8.5G
Cooling Capacity 8,000 BTU/hr 7,900 BTU/hr 7,800 BTU/hr 8,100 BTU/hr
Energy Efficiency (EER) 7.8 7.6 7.5 8.0
Noise Level 52 dB(A) 54 dB(A) 53 dB(A) 51 dB(A)
Weight 18 kg 17.5 kg 16 kg 18.5 kg
Mounting Pattern 8.0″ x 4.8″ 8.0″ x 5.0″ 7.5″ x 4.5″ 8.0″ x 4.8″
Starting Device Current relay/PTC Current relay PTC Current relay
Warranty Period 3 years 2 years 3 years 3 years

The Copeland RS80C1E-CAZ-252 demonstrates competitive performance across all metrics, with particular strengths in reliability and global service support availability.


System Design Considerations

Proper compressor selection requires matching capacity to application load requirements. Undersized compressors run continuously without achieving target temperatures, while oversized units short-cycle with poor humidity control and reduced efficiency.

Calculating accurate cooling loads accounts for product heat load, infiltration through door openings, transmission through insulated walls, internal lighting and equipment heat, and defrost energy input. Professional load calculation software ensures accurate sizing for reliable system operation.

Condensing unit location affects performance significantly. Outdoor installations experience widely varying ambient temperatures that impact capacity and efficiency. Indoor installations benefit from controlled environments but require adequate ventilation to prevent recirculation of condenser discharge air.


Energy Efficiency Optimization

Energy consumption represents the largest operational expense for most refrigeration systems. Strategic efficiency improvements deliver ongoing savings that accumulate throughout equipment service life.

Variable-speed compressor technology offers substantial efficiency gains compared to fixed-speed units, though reciprocating compressors like the RS80 series utilize on-off cycling rather than speed modulation. Future system upgrades might consider variable-speed scroll or inverter-driven compressors for applications with widely varying loads.

Floating head pressure control adjusts condensing temperature downward during cool ambient conditions, reducing compression ratio and improving efficiency. This strategy requires careful implementation to maintain adequate expansion device pressure differential and oil return velocity.

Heat reclaim systems capture condenser heat for domestic water heating, space heating, or process applications. Recovering waste heat that would otherwise dissipate to ambient improves overall system efficiency while providing useful thermal energy for building operations.


Technological Advancement Trends

Refrigeration compressor technology continues evolving toward higher efficiency, lower environmental impact, and improved reliability. Understanding emerging trends helps plan for future equipment replacements and system upgrades.

Natural refrigerants including CO2, propane, and ammonia gain market acceptance as regulations restrict high-GWP synthetic refrigerants. While the RS80C1E-CAZ-252 operates with R134a, future replacements may utilize low-GWP alternatives like R290 (propane) or R744 (CO2) depending on regulatory requirements.

Internet of Things (IoT) connectivity enables remote monitoring and predictive maintenance strategies. Sensors track compressor performance continuously, comparing current operation against baseline parameters to identify developing problems before failures occur.

Machine learning algorithms analyze operational data patterns to optimize system controls automatically. Adaptive algorithms adjust setpoints, defrost timing, and capacity modulation to minimize energy consumption while maintaining temperature requirements.


Professional Installation Guidelines

Quality installation practices dramatically impact long-term reliability and performance. Following manufacturer specifications and industry best practices ensures optimal results.

Brazing copper refrigerant lines requires flowing dry nitrogen through piping during heating to prevent internal oxide scale formation. Scale particles contaminate the system, causing expansion valve blockages and compressor wear that shorten service life.

Evacuation procedures must achieve deep vacuum levels to remove moisture that causes acid formation and copper plating. Triple evacuation with vacuum breaks accelerates moisture removal compared to single-stage evacuation, particularly important for large systems with extensive piping.

Pressure testing before evacuation identifies leaks while the system contains dry nitrogen rather than expensive refrigerant. Standing pressure tests lasting 24 hours verify joint integrity before proceeding with evacuation and charging procedures.


Professional Recommendations

Field experience with the Copeland RS series demonstrates these compressors deliver reliable performance when properly applied and maintained. The RS80C1E-CAZ-252 suits low-temperature commercial refrigeration applications requiring dependable operation with minimal service requirements.

Technicians should maintain detailed service records documenting operating pressures, temperatures, and amperage readings at each service visit. Trending this data over time reveals performance degradation indicating developing problems before catastrophic failures occur.

Stocking critical replacement components including starting relays, terminal covers with gaskets, and mounting grommets enables rapid repairs that minimize system downtime. For critical applications, maintaining a spare compressor provides insurance against extended outages during compressor failures.

Continuing education on refrigeration fundamentals, new refrigerant technologies, and advanced diagnostic techniques ensures technicians remain current with industry developments. Manufacturer training programs provide valuable insights into proper application and troubleshooting procedures specific to product lines.


Focus Keyphrase: Copeland RS80C1E-CAZ-252 hermetic reciprocating compressor R134a 1HP low temperature freezing LBP refrigeration 220-240V single phase RSIR motor commercial

SEO Title: Copeland RS80C1E-CAZ-252: 1HP R134a Compressor for Commercial Freezing | Complete Technical Guide

Meta Description: Comprehensive technical guide to Copeland RS80C1E-CAZ-252 hermetic reciprocating compressor. 1HP, R134a refrigerant, LBP freezing applications -30°C to -10°C. Installation, maintenance, replacement options.

Slug: copeland-rs80c1e-caz-252-compressor-technical-guide

Tags: Copeland compressor, RS80C1E-CAZ-252, R134a refrigerant, hermetic reciprocating compressor, LBP compressor, low temperature freezing, commercial refrigeration, 1 HP compressor, RSIR motor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, RST80C1E-PFV-959, RS80C1E-CAV-252, AE4460Z-FZ1A, NTY65CLX, FR8.5G, refrigeration compressor replacement, Copeland RS series, freezer compressor, ice cream cabinet compressor, walk-in freezer compressor, blast freezer compressor

Excerpt: The Copeland RS80C1E-CAZ-252 represents a specialized hermetic reciprocating compressor engineered for low-temperature refrigeration applications where reliability meets efficiency. This single-phase unit operates on R134a refrigerant and delivers consistent performance in demanding freezing environments ranging from -30°C to -10°C evaporating temperatures. Operating at 220-240V single-phase 50Hz power supply, this unit draws approximately 5 amperes during normal operation, making it suitable for standard commercial electrical systems.




Mbsm,pro, air conditioner, Condor, CsHR09-gcm1t1(0), 9000 btu, 4.5 A, r22, 750 G, T1




Mbsm.pro, Hermetic, Compressor, Electrolux, L88TN, 3/8 Hp ++, R-22, HMBP, Q=416W, tk-15°C/, tc55, 230V 50Hz, L88TN , ACC, ALPENINOX, ASCASO, BARLINE ,L88TN, CUBIGEL, EUNASA, EURFRIGOR , GEV, ICEMATIC, ITV, SCOTSMAN, SIMAG, ZANUSSI

This compressor is no longer available and can be replaced as an alternative by the Aspera NEK2134GK, LBP – R404A, R507,220-240V 50Hz compressor. Differences: L88TN has 8.85 cm3, HBP/MBP, Mineralö lNEK2134GK has 8.78 cm3. Capacity: 3/8 HP Cooling capacity at +5 / +55:562 W, power consumption: 975 W max. Ambient temperature: 43 º C Displacement: 8.85 cm3 Engine type: CSIR Capacity: 400 cm3 Type: ISO VG 68 MINERAL Start element: HST Voltage range: 198-264 V Starting current: 15.8 A Weight: 10.6 kg Connections: 8.1 x 6.5 mm Main winding resistance: 4.38 (25º C) Ohm Winding resistance: 20.6 (25º C) Ohm. cooling power measured for condensation temperature of: 55° C, measuring conditions: ASHRAE

fréon R22
type L88TN
cylindrée 8,9 cm³
système de moteur CSIR
voltage 230 V
hauteur 175,5 mm
construction complètement hermétique
puissance à -10°C 528 W
puissance à -5°C 659 W
puissance à 0°C 808 W
puissance à +5°C 975 W
puissance à -25°C 248 W
puissance à -20°C 323 W
puissance à -15°C 416 W
puissance à +10°C 1161 W
méthode de test ASHRAE
utilisation HMBP
fréquence 50 Hz
poids 10,6 kg



Mbsm.pro, Huayi, Compressor, B25H, R134a, LBP, COMPRESSORS -B SERIES, B25H5 127V, B25H 220V, Water Dispenser, 220-240V/50HZ, 55w, 1/14 hp, 220-240V/60HZ, 63w, 1/12hp

R134a-LBP COMPRESSORS -B SERIES

   
Class: R134a-LBP Compressor
Name: R134a Bseries Compressor
Spec: LowBackPressure
Memo: Used forsmallrefrigerator,water-dispenser,beer-maker

Models PowerSupply
(V/Hz)
Displacement
(cm3)
Cooling
Capacity(W)
HP(W) COP
(W/W)
MotorType Certifications
B22H 220-240V/50HZ 2.2 47 1/15 0.72 RSIR CB,KC
220-240V/60HZ 54 1/14 0.80 RSIR
B22H5 110-115V/60HZ 2.2 54 1/14 0.80 RSIR UL,CUL
B22H5L 110-115V/60HZ 2.2 54 1/14 0.90 RSIR UL,CUL
B25H 220-240V/50HZ 2.6 55 1/14 0.85 RSIR CCC,VDE,CB
INMETRO
220-240V/60HZ 63 1/12 0.94 RSIR
B25H0 100V/60HZ 2.6 63 1/12 0.90
 Model  
Power supply
(V/Hz)
 
 
 Displacement
cm3
 CoolingCapacity(W)  C.O.P(W/W)  Motor Type  Certification
B Series
B22H 220~240/5050 2.2 47 0.72 RSIR CB KC
220~240/60  54 0.80 RSIR
B22HL 220~240/5050 2.2 47 0.85 RSIR CCC CB
220~240/60  54 1.00 RSIR
B22H5 110~120/60  2.2 54 0.80 RSIR UL CUL
B22H5L 110~120/60  2.2 54 0.90 RSIR UL CUL
B25H 220~240/5050 2.6 55 0.85 RSIR CCC VDE CBINMETRO
220~240/60  63 0.94 RSIR
B25H0     100/60 2.6 63 0.90 RSIR
B25H5 110~115/60 2.6 63 0.88 RSIR UL CUL
63 1.10 RSCR
63 1.25 RSCR
B25H5B    110~115/60 2.6 63 1.00 RSIR UL CUL
63 1.10 RSCR
63 1.25 RSCR
B25H5L 110~120/60 2.6 63 0.95 RSIR UL CUL
63 1.10 RSIR
63 1.20 RSCR
B25H7    127/60 2.6 63 0.90 RSIR INMETRO
B30H 220~240/5050 3.1 70 0.88 RSIR CCC VDE CB
220~240/60  80 0.98 RSIR
B30H0 100/60 3.1 80 0.90 RSIR
B30H5 110~115/60 3.1 80 0.98 RSIR UL CUL
80 1.15 RSCR
80 1.25 RSCR
B30H7   127/60 3.1 80 1.05 RSIR CE
B35H 220~240/5050 3.5 79 0.90 RSIR
220~240/60  90 0.95 RSIR
B38H 220~240/5050 3.8 86 0.95 RSIR CCC VDE CBINMETRO
220~240/60  97 1.10 RSIR
B38H5 110~115/60  3.8 97 1.10 RSIR UL CUL
110~115/60  97 1.30 RSCR
B38H7 127/60 3.8 97 1.10 RSIR INMETRO
B43H 220~240/5050 4.3 97 0.95 RSIR CCC VDE CB
220~240/60  110 1.10 RSIR
B43HB 220~240/50  4.3 97 1.25 RSCR
220~240/60  110 1.40 RSCR
B43H5 110~115/60  4.3 110 1.10 RSIR UL CUL
B43H5L 110~120/60  4.3 110 1.10 RSIR UL CUL
B48H 220~240/50  4.8 110 1.05 RSIR
B52HL 220~240/50  5.2 130 1.00 RSIR

* TOLERANCE: Capacity: ≥95%,  Input Power: ≤115%,  Current: ≤110%,  C.O.P≥93%;  HBP-Evaporator Temperature: -5~15
* COOLING  TYPE:  ST=Static Cooling,  FC=Fan Cooling,  OC=Oil Cooling

Note: This  datasheet  describes  certain  operational  parameters  and  conditions  for  operation  of  this  product. If  this  product  is  operated  outside  of  the  parameters  and  conditions  stated  herein,  buyer  assumes  sole  and full responsibility.

Test Conditions LBP MHBP Conversion Table
ASHRAE CECOMAF ASHRAE CECOMAF 1 Kcal/h×1.163=W  
Evaporator Temp.℃ -23.3 7.2 2 Kcal/h×3.968=Btu/h
 Ambience Temp.℃ 32.2 35.0 3 W×3.412=Btu/h
Condenser Temp.℃ 54.4 54.4 4 W×0.864= Kcal/h
Suction Temp.℃ 32.2 35.0 5 EER=COP×3.412
Subcooling Temp.℃ 32.2 46.1 6 Capacity(at 50Hz)×1.16=Capacity(at 60Hz)



Mbsm.pro, Panasonic, rotary, compressor, rotary compressor, R22, 220-240V 50HZ, 2jd550D3AA03, 2JD550D, 35.000 BTU, Rla 5.65 A, Lra 21.0 A, 4.375 Hp, 2.91 Ton

Panasonic rotary compressor R-22, the world’s number one sales. High performance, durable, quiet, compact size Available from 9,000 to 35,000 BTU models.
                              

 

MODEL

BTU.

VOLTAGE

RUNNING

RLA

LRA

LIST PRICE

2PS164D

9,000

220/1/50

30/370

4.1

18.0

3,370

2PS206D

12,000

220/1/50

30/440

5.65

21.0

3,070

2KS210D

12,500

220/1/50

35/370

5.4

27.0

3,370

2KS282D

16,000

220/1/50

45/370

8.0

37.0

5,340

2JS318D

18,000

220/1/50

45/370

8.3

38.0

5,540

2JS330D

20,000

220/1/50

45/370

8.7

41.0

5,800

2JS386D

24,000

220/1/50

60/370

9.75

45.0

6,940

2JS438D

26,000

220/1/50

50/370

12.9

51.0

7,085

2JS464D

28,900

220/1/50

50/370

13.3

64.0

7,840

2JD514D

33,000

220/1/50

60/440

14.2

76.0

8,270

2JD550D

35,000

220/1/50

60/440

14.7

68.0

8,785

 

Fast data
place of origin :
Malaysia
brand name :
panasonic
model number :
2JD550D3AA03.
type :
Refrigeration Compressor
application :
Refrigeration Parts
certification :
THIS
Description :
Matsushita compressor 2JD550D3AA03
Model:
2JD550D3AA03.
BTU:
35,000
Voltage:
220v
Phase :
1ph
Frequency:
50Hz
Running:
30/440
RLA :
5.65
LRA:
21.0
Packing:
wooden

Hot koop 220 V 1 Fase 50Hz Matsushita compressor 2JD550D3AA03

brand name panasonic compressor
place of origin Malaysia
Model 2JD550D3AA03
BTU 35,000
VOLTAGE 220
PHASE 1ph
frequency 50 hz
Running 30/440
RLA 5.65
LRA 21.0
refrigerant r22
description airconditioner compressor

1. High-efficiency, Energy-saving
In order to decrease loss of machine and gas circulation in the process of design and increase high efficiency of the motor and the compressor, optimal matching clearance between dynamic and static parts is adopted. Accordingly, high-efficient compressor can also make room air-conditioner high efficient;

2. Compact, Light
Comparing with traditional compressors, there are comparably less mechanical parts in the compressor and the motor is directly fitted on the shell, so Matsushita compressor is compact and light, which makes room air-conditioner much more compact.

3. High-quality, Reliable performance
Materials for Panasonic rotary compressor are chosen through careful-research, thus made into finished components, finally assembled with computer-aided under strict conditions (temperature \ humidity and dustiness). Therefore, Panasonic rotary compressor has high-quality and reliable performance.

Models for option:

Series Model Capacity Input Power COP Run Capacitor N.W.(KG)
W BTU/H W W/W μF/V
R 2R11B225ASE 1745 5954 585 2.983 12.5/460 8.2
P 2P14S225ANE 2220 7574 705 3.149 30/370 12.0
2P17S225ANQ 2770 9451 885 3.130 30/370 12.0
2P20C225BNG 3245 11071 1080 3.005 30/370 12.6
2P21T225AZB  3510 11975 1130 3.106 30/370 12.4
K 2K22S225BUA 3838 13095 1230 3.120 35/370 17.0
2K25S225BUA  4245 14483 1380 3.076 40/370 17.1
2K28C225DUA 4660 15899 1550 3.006 45/370 17.5
2K32S225AUD 5310 18117 1725 3.078 50/400 18.0
V 2V32S225AUA 5375 18338 1700 3.162 60/370 19.6
2V34S225AUA 5820 19857 1880 3.096 50/370 19.6
2V36S225BUA 6140 20948 1980 3.101 50/400 19.5
2V40S225BUA  6780 23132 2255 3.007 60/440 21.5
2V42S225AUA 7200 24565 2340 3.077 50/370 21.



Mbsm.pro, Compressor, Embraco, Aspera, EMY26CLC, LBP, R600a, 220 – 240V/1/50Hz, 1/12 HP, RSIR, LRA 7.8 A, 83 Wat

Compressor Embraco Aspera EMY26CLC, LBP – R600a, 220 – 240V/1/50Hz, 1/12 HP, discharge 5.19 cm3, engine type RSIR, oil type AB 5, oil volume 180 ml, LRA 7.8 A, 83 W at -23.3 / +54.4 , static cooling, capillary use, weight 7.1 kg


Refrigerant: R600a
Power range(W): 0 – 100 W
Working area: LBP
Design type: Hermetic
Model series: EMY
Use with: Capillary
Power range(HP): 0-2
Power supply: 230 V
Oil type: AB5
Engine type: RSIR
Article condition: New
Info: Oil filled
Shipping weight: 8,10 Kg
Dimensions ( length × width × height ): 22,80 × 15,50 × 16,50 cm
customs tariff number: 84143081
Cooling capacity condition: -23,3 / +54,4
Manufacturer: Embraco Aspera
Model: EMY26CLC
Modelname: EMT26CLP
Stroke volume (cm3): 5,19
Cooling capacity (W): 83
Power (HP): 0,1
Max. Starting current (A): 7,8
Engine type: RSIR
Oil quantity (l): 0,18
Compressor type: Piston




Mbsm.pro, Compressor, Hermetic, Tecumseh, AEZ9440T, R22, 1/3 hp++, MHBP

Basic Info.

Model NO.AEZ9440TLubrication StyleLubricatedCooling SystemAir CoolingCylinder ArrangementBalanced Opposed ArrangementCylinder PositionHorizontalStructure TypeClosed TypeCompress LevelSingle-StageRefrigerant TypeFreonTypeReciprocatingPerformanceLow NoiseDrive ModeElectricPower SourceAC PowerConfigurationStationaryMaterialCopperPiston TypeClosedTrademarkTecumseh HermetiqueTransport PackagePalletSpecificationCE / RoHsOriginChinaHS Code8414301900

Product Description

Tecumseh Hermetique R134a / R404a/ R22 reciprocating compressor

Hermetique R22 HBP  
For Air Conditioning Applications.  
Features:                  
Anti Vibration mounts supplied  
Charged with mineral oil and dry nitrogen  
Crankcase heater on TAG models  
Fan cooling required on all models  
Specifications:                  
Capacity Rating Basis: 35°C Ambient, 11K Return Gas Superheat, 54.5°C Condensing, 46.2°C Liquid entering Expansion Valve.  
Current FLA are given at nominal voltage, rated conditions and 7.2°C Evaporating Temperature.  
Motor Types:                  
PSC = Permanent Split Capacitor, 1 Phase, 50 Hz. 220-240 Volt    
3Ø: 3 Phase, 50 Hz, 400 Volt    
Expansion Device:                  
C = Capillary Tube    
C/V = Capillary Tube or Expansion Valve    
R22 Hermetic                
Model No. Nominal HP Displ. cm³/rev Motor Type Nominal Current FLA Exp. Device Oil Charge cm³ Connections: inches
cm³ Discharge Proc.
AE 5465E 1/2 12.05 PSC 3.2 C 450 3/8 Tube 1/4 Tube 3/8 Tube
AJ 5510F 3/4 18.6 PSC 5.2 C 887 3/8 Tube 1/4 Tube 1/4 Tube
AJ 5512E 1 21.75 PSC 5.9 C 887 3/8 Tube 1/4 Tube 1/4 Tube
AJ 5513E 1 24.2 PSC 6 C 887 3/8 Tube 1/4 Tube 1/4 Tube
AJ 5515E 1 1/4 25.95 PSC 7.2 C 887 1/2 Tube 5/16 Tube 1/4 Tube
AJ 5518E 1 1/2 32.7 PSC 9.3 C 887 1/2 Tube 5/16 Tube 1/4 Tube
AJ 5519E 1 1/2 34.45 PSC 9.96 C 887 1/2 Tube 5/16 Tube 1/4 Tube
FH 5522E 1 3/4 39.95 PSC 9 C 1330 5/8 Tube 3/8 Tube 5/16 Tube
TFH 5522E 1 3/4 39.95 3.8 C/V 1330 5/8 Tube 3/8 Tube 5/16 Tube
FH 5524E 2 43.5 PSC 10 C 1330 5/8 Tube 3/8 Tube 5/16 Tube
TFH 5524E 2 43.5 4 C/V 1330 5/8 Tube 3/8 Tube 5/16 Tube
FH 5527E 2 1/4 49.1 PSC 12 C 1330 5/8 Tube 3/8 Tube 5/16 Tube
TFH 5527E 2 1/4 49.1 4.2 C/V 1330 5/8 Tube 3/8 Tube 5/16 Tube
FH 5531E 2 1/2 56.65 PSC 14.1 C 1330 3/4 Tube 3/8 Tube 5/16 Tube
TFH 5531E 2 1/2 56.65 8 C/V 1330 3/4 Tube 3/8 Tube 5/16 Tube
FH5540E 3 74.25 PSC 18.6 C 1330 3/4 Tube 3/8 Tube 5/16 Tube
TFH 5540E 3 74.25 6 C/V 1330 3/4 Tube 3/8 Tube 5/16 Tube
TFH 5540E 3 74.25 6 C/V 1330 78 1/2 Valve 5/16 Tube
TAG 5546E 3 3/4 90.2 6.6 C/V 1960 7/8 Tube 1/2 Tube 3/8 Tube
TAG 5553E 4 100.7 7.4 C/V 1960 7/8 Tube 1/2 Tube 3/8 Tube
TAG 5561E 5 112.5 9 C/V 1960 7/8 Tube 1/2 Tube 3/8 Tube
TAG 5568E 6 124.4 9.6 C/V 1960 7/8 Tube 1/2 Tube 3/8 Tube
TAG 5573E 6 1/2 134.8 11 C/V 1960 7/8 Tube 1/2 Tube 3/8 Tube
                   
Hermetique R22 M/HBP
For Medium / High Temperature Applications
Features:                  
Anti-Vibration mounts supplied
Charged with mineral oil and dry nitrogen
Rotalock suction valve on CAJ/TAJ models
Crankcase heater on FH/TFH and TAG models
Oil sight glass on FH/TFH and TAG models
Fan cooling required on all models
All models suit capillary tube or expansion valve operation
Rotalock suction and discharge valves on FH/TFH and TAG models
Specifications:                  
Capacity Rating Basis: 35°C Ambient, 11K Return Gas Superheat, 54.5°C Condensing, 46°C Liquid entering Expansion Valve.
Current FLA are given at nominal voltage, rated conditions and 7.2°C evaporating temperature.
Motor Types:                  
CSIR: Capacitor start, Induction run } 1 Phase, 50 Hz, 220-240 Volt
CSR: Capacitor start and run
3Ø: 3 Phase, 50 Hz, 400 Volt
Conversion: Watts x 3.412 = BTU/Hr BTU/Hr x 0.293 = Watts
R22 Hermetic                
Model No. Nominal HP Displ. cm³/rev Motor Type Nominal Current FLA Oil Charge cm³ Connections: inches    
Suction Discharge    
AEZ 4425E 1/5 4.5 CSIR 1.75 450 1/4 Tube 3/16 Tube    
AEZ 4430E 1/4 5.7 CSIR 2.2 450 1/4 Tube 3/16 Tube    
AEZ 4440E 1/3 7.55 CSIR 2.6 450 1/4 Tube 3/16 Tube    
AEZ 9440T 1/3 7.55 CSR 2.03 450 3/8 Tube 1/4 Tube    
CAE 4450E 3/8 9.4 CSIR 3.3 450 3/8 Tube 1/4 Tube    
CAE 9450T 3/8 9.5 CSR 2.6 450 3/8 Tube 1/4 Tube    
CAE 9460T 1/2 11.3 CSR 3.2 450 3/8 Tube 1/4 Tube    
CAJ 9408T 5/8 15.2 CSR 3.68 887 1/2 Valve 5/16 Tube    
CAJ 9510T 1 18.3 CSR 4.8 887 5/8 Valve 5/16 Tube    
CAJ 9513T 1 1/8 24.2 CSR 5.9 887 5/8 Valve 5/16 Tube    
CAJ 4517E 1 1/4 25.95 CSR 6.1 887 5/8 Valve 3/8 Tube    
TAJ 4517T 1 1/2 25.95 2.5 887 5/8 Valve 3/8 Tube    
TAJ 4519T 1 1/2 34.45 3.5 887 5/8 Valve 1/2 Valve    
FH 4524F 2 43.5 CSR 9.55 1480 5/8 Valve 1/2 Valve    
TFH 4524F 2 4.35 3.9 1480 7/8 Valve 1/2 Valve    
FH 4531F 2 1/2 56.65 CSR 12.6 1480 7/8 Valve 1/2 Valve    
TFH4531F 2 1/2 56.65 4.75 1480 7/8 Valve 1/2 Valve    
TFH 4540F 3 74.25 6.08 1480 7/8 Valve 1/2 Valve    
TAG 4546T 4 90.2 6.6 1960 7/8 Valve 5/8 Valve    
TAG 4553T 4 1/2 100.7 7.4 1960 7/8 Valve 5/8 Valve    
TAG 4561T 5 112.5 9 1960 1 7/8 Valve 5/8 Valve    
TAG 4568T 6 124.4 9.6 1960 1 7/8 Valve 5/8 Valve    
TAG 4573T 6 1/2 134.8 11 1960 1 7/8 Valve 5/8 Valve    
                   
                   
Tecumseh Hermetique R134a  
The world renowned L’Unite Hermetique compressors are manufactured by Tecumseh.  
Features:                  
Charged with polyolester oil and dry nitrogen  
Crankcase heater on FH/TFH and TAG models  
Oil sight glass on FH/TFH and TAG models  
Rotalock valves are included for all valve connection compressors  
Anti-vibration mounts supplied  
Single Phase – Medium High SST          
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
CAJ4476Y 5/8 21.75 Fan 887          
CAJ4492Y 3/9 25.95 Fan 887          
CAJ4511Y 1 32.7 Fan 887          
FH4518Y 1 1/2 53.2 Fan 1480          
FH4525Y 2 74.25 Fan 1480          
                   
Three Phase – Medium High SST          
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
TAJ4511Y 1 32.7 Fan 887          
TFH4518Y 1 1/2 53.2 Fan 1480          
TFH4525Y 2 74.25 Fan 1480          
TAG4528Y 2 1/2 90.2 Fan 1960          
TAG4534Y 2 3/4 100.7 Fan 1960          
TAG4537Y 3 112.5 Fan 1960          
TAG4543Y 3 1/2 124.4 Fan 1960          
                   
Superceded Models              
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
AEZ4425Y 1/5 7.55 Fan 450          
AEZ4430Y 1/4 8.85 Fan 450          
CAE4440Y 3/8 12.05 Fan 450          
CAE4448Y 1/3 14.15 Fan 450          
CAJ4452Y 1/3 15.2 Fan 887          
CAE4456Y 1/2 16 Fan 450          
CAJ4461Y 1/2 18.3 Fan 887          
                   
Tecumseh Hermetique R404A      
The world renowned L’Unite Hermetique compressors are manufactured by Tecumseh.    
Features:                  
                   
Charged with polyolester oil and dry nitrogen    
Crankcase heater on FH/TFH and TAG models    
Oil sight glass on FH/TFH and TAG models    
Rotalock valves are included for all valve connection compressors    
Anti-vibration mounts supplied    
                   
Specifications:                  
Capacity Rating Basis: 35°C Ambient, 11K Return Gas Superheat, 54.5°C Condensing, 46°C Liquid entering Expansion Valve.    
Current FLA are given at nominal voltage, rated conditions and 7.2°C Evaporating Temperature.    
Motor Types:                  
CSIR: Capacitor Start, Induction Run 1 Phase, 50 Hz, 220-240 Volt    
CSR: Capacitor Start and Run    
3Ø: 3 Phase, 50 Hz, 400 Volt    
All models are also suitable for operation with R507    
Single Phase – Medium High SST          
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
CAJ9480Z 5/8 15.2 Fan 887          
CAJ9510Z 1 18.3 Fan 887          
CAJ9513Z 1 1/8 24.2 Fan 887          
CAJ4517Z 1 1/4 25.95 Fan 887          
CAJ4519Z 1 1/2 34.45 Fan 887          
FH4522Z 1 3/4 39.95 Fan 1480          
FH4524Z 2 43.5 Fan 1480          
FH4531Z 2 1/2 56.65 Fan 1480          
FH4540Z 3 74.25 Fan 1480          
                   
                   
Three Phase – Medium High SST          
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
TAJ9480Z 5/8 15.2 Fan 887          
TAJ9510Z 1 18.3 Fan 887          
TAJ9513Z 1 1/8 24.2 Fan 887          
TAJ4517Z 1 1/4 25.95 Fan 887          
TAJ4519Z 1 1/2 34.45 Fan 887          
TFH4522Z 1 3/4 39.95 Fan 1480          
TFH4524Z 2 43.5 Fan 1480          
TFH4531Z 2 1/2 56.65 Fan 1480          
TFH4540Z 3 74.25 Fan 1480          
TAG4546Z 4 90.2 Fan 1960          
TAG4553Z 4 1/2 100.7 Fan 1960          
TAG4561Z 5 112.5 Fan 1960          
TAG4568Z 6 124.4 Fan 1960          
TAG4573Z 6 1/2 134.8 Fan 1960          
                   
Single Phase – Low SST              
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
CAE2417Z 1/3 11.3 Fan 450          
CAE2420Z 1/2 12.54 Fan 450          
CAE2424Z 5/8 15 Fan 450          
CAJ2428Z 1/2 15.2 Fan 887          
CAJ2432Z 5/8 18.3 Fan 887          
CAJ2446Z 3/4 26.15 Fan 887          
CAJ2464Z 1 1/2 34.45 Fan 887          
FH2480Z 2 53.2 Fan 1625          
FH2511Z 2 1/2 74.25 Fan 1625          
                   
Three Phase – Low SST              
Model No. Nominal HP Displacement: cm3/rev Cooling Oil Charge: ml          
TAJ2464Z 1 1/2 34.45 Fan 887          
TFH2480Z 2 53.2 Fan 1625          
TFH2511Z 2 1/2 74.25 Fan 1625          
TAG2516Z 4 112.5 Fan 1960          
TAG2522Z 5 1/2 134.8 Fan 1960          
                   
Three Phase – Parallel Applications          
Model No. Nominal HP Displacement: cm3/rev Application: SST Cooling Oil Charge: ml        
TAGP4546Z 4 90.2 Medium Fan 1960        
TAGP4553Z 4 1/2 100.7 Medium Fan 1960        
TAGP4561Z 5 112.5 Medium Fan 1960        
TAGP4568Z 6 124.4 Medium Fan 1960        
TAGP4573Z 6 1/2 134.8 Medium Fan 1960        
TAGP2516Z 4 112.5 Low Fan 1960        
TAGP2522Z 5 1/2 134.8 Low Fan 1960        



Mbsm.pro, Compressor, ELECTROLUX, 3/4 Hp ++ (big), R-12, S26TY, HMBP

Commercial R12 – Medium Suction Temperature

Capacity range (watts) Aspera Kirby Old Kirby Model Danfoss L’Unite Hermetique Unidad Electrolux Kelvinator Necchi Bulkon
201-250 AE6LMY AE67ZD7 AE6LMA TL4B L57PX S88ND M4J
250-300 M5J
301-350 A5144A AE8MG AE59ZF9 AE8LMA
351-400 AE9MHY AE4425A AE9MHA FR6B CAE59ZF9 L76PX M7J
401-450 A5160A FR7.5B L68TY S54FD
450-500 A6170A AEV9LMY AE7416A AE10LMA FR8.5B CAE41ZF11 L88TX S44ND M9J
501-550 S54FD S44CFD M11, A9
551-600 T6185A AE12LMY AE12LJ FR10B CAE4440A P12TY S33FD S33TF
601-650 E6187A FR11B SC10B
651-700 AE14LMY AE7423A AE14LMA P14TY KB14B1
701-800 T6213A SC12B CAJ4452A A13
801-900 AE16LMY AE16LMA AE16LJ SC15B N17 KB19B1
901-1000 AJ18MY AJ7428A KB19B1
1001-1200 T6215A AJ22LMY AJ7434A AJ22LJ SC18B CAJ4461A S18TY S5050FDH KB23B1
1201-1400 J6220A AJ26LMY AJ7445A AJ26LJ SC21B S26TY S7575FDH KB26B1
1401-2000 J6226A AJ34LMY AJ7457A AJ34LJ CAJ4511A S34TY S1010FDH KB37B1
2001-2500 H6238A AH49MHY AH4514A CAH4518A TAH4518A
2501-3500 H6253A AH74MHY AH4521A CAH4524A TAH4524A



Mbsm.pro, Compressor, ACC, Cubigel, Huayi, Electrolux, ZEM, MPT14LA , MPT14RA, LBP , R404A, R507, 1/2HP, 220-240V

Compressor Tecumseh L` Unite CAJ2432Z, LBP – R404A, 220 – 240V, 50 Hz, 1 phase, discharge: 18.3 cm3, oil type: POE, oil charge: 887 cm3, electrical equipment: CSR, cooling power 381 W at -35 / +40 °C, connection: suction: 1/2 inch, discharge: 5/16 inch, sound level: 56 dBA, start capacitor: 8 8 uF/250V, run capacitor: 15 uF/400V, expansion device: capillary or expansion valve, height: 271 mm, weight: 21.5kg

Type: Low back pressure (LBP)
Refrigerant: R404a/507
Displacement: 14.32cm³
Power: 1/2CV
Voltage: 230V – 50Hz
Single-phase
Motor type: CSR
Weight: 13.4 kg

Evaporation temperature
-40°C: 243W
-30°C: 420W
-25°C: 535W
-10°C: 988W