Mbsm.pro, compressor, Gree, Air conditioner, OXSH-F375E090, OXSH-F375, 22100 BTU, 37.50 cm3, 6477 w, capacitor 60 uf, 1.8 ton, 2.8 hp, 220 v, 1ph, r22




Mbsm.pro, Solutions, F0, Code, F0 Error, Gree, Mini Split, Air Conditioner

F0 Error Gree Mini Split Air Conditioner
If your place has a Mini Split type of Air Conditioner, then the meaning of F0 Error would be the
low level of refrigerant.
If the refrigerant in your air conditioner is low, there can be many reasons.
It may happen that the refrigerant was charged less while installing the air conditioner.
If your air conditioner is old, then the possibility of leakage also increases.
Due to leaking in the unit, the gas pressure decreased. And we face an F0 malfunction.

Causes of Gree Mini Split AC F0 Error
. Sometimes technicians didn’t charge proper refrigerant in the AC unit while installation.
This is why we face F0 error when we start our air conditioner.
. The liquid valve is closed or not open properly.
. Have a leakage somewhere in the unit so the refrigerant level is low.
. Clogging in the pipeline.
F0 Error Code Gree Mini Split AC Troubleshooting
Make sure if the valves are completely open or not. if not, open both of the valves
completely.
Check the refrigerant stand pressure is normal according to the refrigerant type. refill
it.
Check if the air conditioner unit has leakage somewhere. Repair the leakage and refill
the refrigerant.
Remove the refrigerant and flash the unit with Nitrogen pressure if the capillary and
filter are in choking condition




Mbsm.pro, Compressor, Gree, Rotary Compressors, QXSH-F42E030, 24000 BTU/HR, 2 ton, 3 Hp, 1PH / 220 v, r22

Technical Features

Refrigerant: R22
Displacement: 42.0 Cm3/Rev
Capacity: 24000 BTU
Power Input: 2238 W
Application: Air Conditioning
Cop(W/W): 3.25
BRAND GREE
COMPRESSOR TYPE ROTARY
POWER SUPPLY 220-240V
REFRIGERANT R22
FREQUENCY (HZ) 50
APPLICATION ROOM AIR-CONDITIONER(T3 CONDITION)
REFRIGERANT CHARGE LIMIT 2000G MAX
VOLTAGE (RATED VOLTAGE)/FREQUENCY/PHASE 220-240 V~(230V)/50 HZ/1 PHASE
PUMP TYPE ROTARY
THE NUMBER OF CYLINDERS DOUBLE CYLINDER
CYLINDER NOMINAL VOLUME 42 CM3
BRAND OF REFRIGERANT OIL ATMOS-NM56EP OR EQUIVALENT
REFRIGERANT OIL CHARGE 850 ML
WEIGHT(REFRIGERANT OIL INCLUDED) 23 KG
SUCTION PIPE I.D. Φ15.6±0.05 MM
DISCHARGE PIPE I.D . Φ9.7±0.06 MM



Mbsm.pro, GREE, Air Conditioners, VRF-system, GMV-615WM/G-X, inverter, 22 hp, 615000 btu/h, 61.5 kw, Cooling / heating, r410a, dc motor, multi-speed, T3, 380-415V 3N~50/60Hz

Features

Model VRV System v6 GMV-615WM/G-X
Airflow rate:
10500 m3 /h
H/p 22 Hp
Served area, m2 600
Power supply, f/Hz/V 3/50;60/380-415
Refrigerant type R410A / 8300 G
Noise level of the outdoor unit (min/max), dB 63
External block weight, kg 350
Outdoor unit dimensions (WxHxD), cm 134x169x77.5
Tubing diameter (liquid), mm (in) ф15,9
Tubing diameter (gas), mm (in) ф28,6
Guaranteed outdoor temperature range (cooling), °С -5…+52
Guaranteed outdoor temperature range (heating), °C -30…+24
Air conditioner type VRF system
Power in heating mode, kW 69
Power consumption during cooling, kW 16.2
Power consumption during heating, kW 16.9
Inverter There is
Cooling capacity (BTU) Cooling capacity:
210000 btu / 17.5 Ton
Heating capacity:
235000 btu / 19.5 Ton
Main Modes Cooling / heating
Power in cooling mode, kW 61.5



Mbsm.pro, GRee, air conditioner, GWHD(14)NK6LO(LC)(LH), GWHD(14)NK6LO, CB228W08401, CB228W08400, 14000 btu, Inverter Rotary, Compressor, QXA-B141zF030A, 2 hp-, 1440 w, lra 25 A, DC block controller, r410a, 220 v, 50 hz, 900 to 7200 RPM

Mbsm.pro, GRee, air conditioner, GWHD(14)NK6LO(LC)(LH), GWHD(14)NK6LO, CB228W08401, CB228W08400, 14000 btu, Inverter Rotary, Compressor, QXA-B141zF030A, 2 hp, 1440 w, lra 25 A, DC block controller, r410a, 220 v, 50 hz, 900 to 7200 RPM




www.mbsm.pro, GREE , Mini Split , Air Conditioner ,Error Codes E6 , How To Fix

The error E6 comes from the engine, it is the electronic engine card if it is an inverter range.
Communication error E6  Between Outside and inside

* Test cable connection
* Test Inside Unit First without cable
* Test Outside unit without cable
* Check Fluid Pressure
* Test Fan Rotation
* Test Condensateur fonction






www.mbsm.pro, Branchement Unité extérieure , LG ,Media , Général , Samsung, Haier , Galanze ,Gree ,Maxwelle, Vestel

www.mbsm.pro, Branchement Unité extérieure , LG ,Media , Général , Samsung, Haier , Galanze ,Gree ,Maxwelle, Vestel

WARNING: