Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide

What Is the Danfoss SLV15CNK?

If you’ve ever opened the back panel of a commercial chest freezer or a light commercial display case and found a compact, brushless compressor with a controller module attached to it, there’s a good chance you were looking at a Danfoss Secop SLV15CNK. This variable-speed hermetic compressor is one of the most widely deployed LBP (Low Back Pressure) units in European and international commercial refrigeration — and for good reason.

Originally built under the Danfoss brand before the compressor division was spun off as Secop GmbH in 2010, the SLV15CNK has carved out a reliable reputation across commercial food retail, light industrial cooling, and even medical cold-chain applications. The unit pictured above — serial reference 561108N4, profile 104H — is the standard 220–240V, 50/60 Hz variant using R290 (propane) refrigerant, one of the most eco-friendly natural refrigerants available today.


Complete Technical Specifications Table

Parameter Value
Model SLV15CNK / SLV15CNK.2
Utilisation (MBP/HBP/LBP) LBP only (Low Back Pressure)
Domain (Freezing/Cooling) Deep Freezing — evap. temp. –40°C to –10°C
Cooling Wattage at –23°C ~446 W (nominal at standard LBP conditions)
Cubic Feet Cooled ~7–10 ft³ (small to medium chest freezer)
Litres Cooled ~200–280 litres
Kcal/h ~383 Kcal/h
TON ~0.127 TON of refrigeration
Oil Type & Quantity Polyolester (POE) — 600 cm³
Horsepower (HP) 5/8 HP (~0.60 HP)
Refrigerant Type R290 (Propane) — max charge 150 g
Power Supply 220–240V / 1Ph / 50–60 Hz (range: 180–254V)
Cooling Capacity BTU ~1521 BTU/h (LBP nominal)
Motor Type Permanent Magnet (TRI — 3-phase inverter driven)
Displacement 15.28 cm³
Winding Material Copper (3-phase windings, resistance ~7.7 Ω at 25°C)
Pression Charge LBP / LST — max condensing temp 55°C (65°C short-term)
Capillary Approx. 3m / Ø0.31 mm (application-dependent — verify with OEM data)
Compatible Refrigerator Models AHT Deep Freezers, light commercial chest freezers, display cases, ice machines, beverage coolers
Temperature Function –40°C to –10°C evaporating; –35°C practical freezer operation
With Fan or Not Yes — F2 fan cooling required (3.0 m/s airflow on compressor & controller)
Commercial or Domestic Commercial (light commercial / food retail)
Amperage in Function Max 4.6 A
LRA (Locked Rotor Amperage) Electronic cut-off (no traditional LRA — inverter-controlled)
Type of Relay No traditional relay — uses 105N46xx Series SLV Electronic Controller
Capacitor No start/run capacitor — inverter-driven (variable speed 2000–4000 RPM)
Country of Origin & Export Manufactured in Slovakia (Secop GmbH) — exported globally: EU, UK, Middle East, North Africa, Australia, Asia

What Makes This Compressor Special?

Variable Speed Technology

Most technicians encounter fixed-speed compressors day in and day out. The SLV15CNK breaks that mold entirely. It’s a variable speed drive (VSD) compressor, meaning its speed adapts continuously between 2000 and 4000 RPM based on thermal demand. The result is dramatically reduced energy consumption during low-load periods, less mechanical wear, and quieter operation — all things that matter enormously in a commercial food retail environment where a freezer runs 24/7, 365 days a year.

R290 — The Natural Refrigerant Advantage

R290 (propane) is not new, but its adoption in commercial compressors has accelerated rapidly in recent years thanks to its near-zero Global Warming Potential (GWP = 3) compared to the synthetic alternatives it replaces. The SLV15CNK uses a maximum charge of just 150 grams, which keeps it below the safety threshold for flammable refrigerant use in occupied spaces. That tiny charge, combined with propane’s excellent thermodynamic properties, means this compressor achieves high efficiency with a very light environmental footprint.

The Controller Dependency

One detail technicians absolutely must not overlook: this compressor will not function without its dedicated SLV electronic controller (105N46xx series). The label on the unit itself clearly states “Only with SLV controller.” This is not a traditional hermetic compressor you can simply wire up to a relay and a capacitor. The controller handles speed regulation, current protection, speed monitoring, and thermal protection all in one unit. Replacing or sourcing this controller is as important as finding the compressor itself.

Fan Cooling Is Mandatory

At all ambient conditions (32°C, 38°C, and 43°C), the datasheet specifies F2 cooling — meaning fan airflow of at least 3.0 m/s directly on both the compressor body and the electronic controller unit. Attempting to run this compressor without proper forced airflow will trigger thermal protection and lead to premature failure. This is a common oversight when installers replace the compressor without checking the cabinet’s fan arrangement.


Replacement Compressors — Same Gas (R290)

When the SLV15CNK reaches end of life or fails, the most straightforward replacements use the same R290 refrigerant. Here are five proven options:

# Replacement Model Brand Notes
1 SLV15CNK.2 (104H8541) Secop/Danfoss Direct drop-in replacement — latest revision
2 SLV12CNK.2 Secop/Danfoss Slightly lower displacement, same gas and controller family
3 SLV20CNK.2 Secop/Danfoss Higher capacity option — same R290/controller platform
4 NLV14CNK Secop/Danfoss Fixed-speed variant on R290 LBP — requires relay/capacitor
5 SCM10CNX.2 Secop R290, standard hermetic, LBP — no inverter controller needed

Replacement Compressors — Different Refrigerant

If R290 is not available in your region, or if you’re retro-fitting an older system, here are five equivalents using alternative refrigerants with comparable capacity:

# Replacement Model Brand Refrigerant Notes
1 SC15G Secop/Danfoss R404A / R507A Classic LBP hermetic, no controller needed
2 NL11MF Secop/Danfoss R134a LBP/MBP, standard hermetic
3 CAJ9513Z Embraco R404A Direct LBP replacement at similar capacity
4 NEBL2134Z Embraco R600a For domestic/light LBP applications
5 MTZ32-4VM Danfoss R452A/R404A Slightly oversized but compatible for retrofits

⚠️ Important: Switching refrigerants requires changing the oil type, capillary tube, and verifying all safety certifications. Always consult the system manufacturer before cross-refrigerant replacement.


Typical Applications — Which Freezers Use This Compressor?

The SLV15CNK is the heart of many products you’ll recognize from the supermarket floor:

  • AHT Australian series chest freezers (confirmed via MBSM documentation)
  • Light commercial open-top island freezers
  • Vertical display freezer cabinets (small commercial)
  • Beverage coolers with sub-zero requirements
  • Frozen food display cases at petrol stations and convenience stores
  • Ice cream chest cabinets in retail environments

The AHT connection is particularly well-documented — AHT is a major manufacturer of commercial freezers widely deployed across European and African retail chains, and the SLV15CNK is one of their standard compressor choices.


Installation & Service Notes

A few practical points every technician should keep in mind when working with this unit:

Controller wiring: Always refer to the 105N46xx wiring diagram. Polarity and signal connections matter — the controller is not interchangeable between all SLV variants.

Refrigerant handling: R290 is flammable (Class A3). Work in ventilated areas, avoid open flames, and use an R290-certified manifold gauge set. The 150g charge limit means leaks are rare but must be taken seriously.

Oil compatibility: POE oil is mandatory with R290 in this application. Do not substitute mineral oil or alkylbenzene — POE is pre-filled at the factory at 600 cm³.

Mounting vibration: The compressor ships with rubber mounting grommets. Always re-use or replace them — running on a hard mount increases noise and mechanical fatigue.

Capillary tube: The reference capillary for AHT applications is approximately 3m / 0.31mm diameter, but always measure and verify against the original system before cutting new tubing.


Why This Compressor Matters in 2025 and Beyond

The refrigeration industry is at a turning point. Synthetic refrigerants with high GWP are being phased out under F-Gas regulations in Europe and similar legislation worldwide. The SLV15CNK — running on propane with a permanent magnet variable-speed motor — represents exactly the direction the industry is heading: natural refrigerants, intelligent speed control, and reduced energy consumption without compromising reliability.

For service technicians, understanding this platform deeply isn’t just useful today — it’s preparation for the next decade of commercial refrigeration work.




Mbsm.pro, Compressor, Secop, Danfoss, 5/8 Hp, LBP, INVERTER, Variable speed LBP, SLV15CNK, SLV15CNK.2, 104H8568, 104H8541, R290, 230V, refrigeration, Deep freezer AHT Australian, Capillary 3m/ 031

Danfoss SLV15CNK compressor. 2

  • R290 refrigerant
  • LBP working range: -40 to -10 degrees C
  • voltage 220-240V, 50-60Hz
  • capacity 15.28cc
  • weight 13.00 kg
Model: SLV15CNK. 2 Evaporation temperature
Factor: R290 -40 o C -35 o C -30 o C -25 o C -23.3 o C -20 o C -15 o C -10 o C -5 o C
Capacity [W] at a condensing temperature of 45 ° C 325 460 615 792 858 996 1228 1494

Détails du produit

 

Poids brut 14.31 kg
Poids Net 13.69 kg

 

Alimentation du compresseur [V/Ph/Hz] 220/1/50 220/1/60
Applications LBP
Charge en fluide frigorigène [kg] [Max] 0.15 kg
Code de configuration Simple
Couleur Noir
Description Kit d’entretien du compresseur SLV15CNK
Diamètre de raccordement à l’aspiration [mm] 10.2 mm
Diamètre du raccord au refoulement [mm] 6.2 mm
Diamètre du raccordement du traitement [mm] 6.2 mm
Désignation du modèle Compressor
   
Faible valeur de plage de tension à 50 Hz [V] 187 V
Faible valeur de plage de tension à 60 Hz [V] 187 V
Faible valeur de tension nominale à 50 Hz [V] 220 V
Faible valeur de tension nominale à 60 Hz [V] 220 V
Fluides R290
Fréquence [Hz] 50/60
Hauteur de la base [mm] 203 mm
Hauteur du raccordement de refoulement [mm] 100 mm
Hauteur du raccordement du traitement [mm] 183 mm
Hauteur raccordement aspiration [mm] 183 mm
Hauteur totale [mm] 209 mm
Injection de liquide No
Longueur [mm] 255 mm
Matériel du raccord au process Cuivre
Matériel du raccord d’aspiration Cuivre
Matériel du raccord de refoulement Cuivre
Niveau d’énergie de l’application LBP vitesse variable
Notes concernant le raccord de refoulement Bouchon en caoutchouc
Notes concernant le raccordement au process Bouchon en caoutchouc
Notes concernant le raccordement à l’aspiration Bouchon en caoutchouc

Product details

 

Gross weight 12.33 kg
Net weight 12.33 kg

 

Application energy level Variable speed LBP
Applications LBP
Base plate type Universal
Brand technique Reciprocating compressor
Capacity control INVERTER
Colour Black
Compressor power supply [V/Ph/Hz] 220/1/50 220/1/60
Configuration code Single
Description SLV15CNK.2
Discharge connection angle [°] 37 °
Discharge connection comments Rubber plug
Discharge connection diameter [mm] 6.2 mm
Discharge connection height [mm] 100 mm
Discharge connection material Copper
Economizer No
Free gas volume [cm3] 1410 cm³
Frequency [Hz] 50/60
Height from baseplate [mm] 203 mm
High value of nominal voltage at 50Hz [V] 230 V
High value of nominal voltage at 60Hz [V] 230 V
High value of voltage range at 50Hz [V] 254 V
High value of voltage range at 60Hz [V] 254 V
Length [mm] 255 mm
Liquid injection No
Low value of nominal voltage at 50Hz [V] 208 V
Low value of nominal voltage at 60Hz [V] 220 V
Low value of voltage range at 50Hz [V] 187 V
Low value of voltage range at 60Hz [V] 198 V
Model Number SLV15CNK.2
Motor type DC/PM
No. of phases (compressor) 0
Oil quantity [cm3] 600 cm³
Oil type POE
Packing format Industrial pack
Packing quantity 80
Phase 1
Process connection angle [°] 37 °
Process connection comments Rubber plug
Process connection diameter [mm] 6.2 mm
Process connection height [mm] 183 mm
Process connection material Copper
Refrigerant R290
Refrigerant charge [kg] [Max] 0.15 kg
Rotational speed at 50Hz [rpm] 2900 rpm
Rotational speed at 60Hz [rpm] 3500 rpm
Segment usage Refrigeration LT
Suction connection angle [°] 37 °
Suction connection comments Rubber plug
Suction connection diameter [mm] 10.2 mm
Suction connection height [mm] 183 mm
Suction connection material Copper
Swept volume [cm3] 15.28 cm³
Technology Reciprocating
Total height [mm] 209 mm
Type SC
Type designation Compressor
Voltage 50Hz [V] 220 V
Voltage 50Hz [V] [Max] 240 V
Voltage 60Hz [V] 208 V
Voltage 60Hz [V] [Max] 230 V
Width [mm] 151 mm
Winding temperature short term [°C] [Max] 135 °C
Winding temperature stat [°C] [Max] 125 °C



Mbsm.pro, Compressor, R290, 0.110Kg, SC15CNX.2, Secop, DANFOSS, SC15CNX, 15,28cm³, LBP, 230V, Hermetic piston compressors, 5/8 Hp, 104h 8568, 104h8568

Additional information

Voltage (V) 230Vac
Frequency (hz) 50
Range LBP
Displacement (cm3) 15,28 cm³
Cooling capacity (W) 400W
Conditions (°C) -30 / +45°C
Refrigerant R290
Suction line 8.2mm
Liquid line 6.2mm
Height (mm) 219
Weight (kg) 13,1kg
Oil POE
Compressor type Hermeettinen mäntäkompressori

Poids brut 13.5 kg
Poids Net 13.5 kg

 

Alimentation du compresseur [V/Ph/Hz] 220-240/1/50
Applications LBP
Capacitance du condensateur de démarrage 80 µF
Charge en fluide frigorigène [kg] [Max] 0.15 kg
Code de configuration Simple
Couleur Noir
Courant d’appel HST [A] 16.2 A
Courant d’appel LST [A] 20.1 A
Description SC15CNX
Diamètre de raccordement à l’aspiration [mm] 10.2 mm
Diamètre du raccord au refoulement [mm] 6.2 mm
Diamètre du raccordement du traitement [mm] 6.2 mm
Désignation du modèle Compresseur
Emballage (format) Emballage industriel
Faible valeur de plage de tension à 50 Hz [V] 198 V
Faible valeur de plage de tension à 60 Hz [V] 0 V
Faible valeur de tension nominale à 50 Hz [V] 220 V
Faible valeur de tension nominale à 60 Hz [V] 0 V
Fluides R290
Fréquence [Hz] 50
Hauteur de la base [mm] 203 mm
Hauteur du raccordement de refoulement [mm] 100 mm
Hauteur du raccordement du traitement [mm] 183 mm
Hauteur raccordement aspiration [mm] 183 mm
Hauteur totale [mm] 209 mm
Injection de liquide No
Longueur [mm] 255 mm
LRA HST 60 Hz [A] 16.2 A
LRA HST [A] 16.2 A
LRA LST [A] 15.8 A
Matériel du raccord au process Cuivre
Matériel du raccord d’aspiration Cuivre
Matériel du raccord de refoulement Cuivre
Niveau d’énergie de l’application Universel LBP/MBP
Nombre de phases (compresseur) 1
Nombre de phases (ventilateur) 1
Notes concernant le raccord de refoulement Bouchon en caoutchouc
Notes concernant le raccordement au process Bouchon en caoutchouc
Notes concernant le raccordement à l’aspiration Bouchon en caoutchouc
N° de modèle SC15CNX
Oil type POE
Phase 1
Profondeur [mm] 151 mm
Quantité d’huile [cm³] 550 cm³
Quantité par emballage 80
raccord de refoulement équerre [°] 37 °
raccord d’aspiration équerre [°] 37 °
Raccordement de process équerre 37 °
RLA 3.10 A
Régulation de la puissance Vitesse fixe
Résistance de l’enroulement auxiliaire (enroulement de démarrage) pour compresseurs monophasés [ohm] 13.5 Ohm
Résistance de l’enroulement auxiliaire (enroulement de démarrage) pour compresseurs monophasés à pistons [ohm] 13.5 Ohm
Résistance de l’enroulement principal pour compresseurs monophasés [Ohm] 5.1 Ohm
Technique de la marque Compresseur à pistons
Technologie Piston
Température d’enroulement max. continue [°C] [Max] 125 °C
Température de l’enroulement à court terme [°C] [Max] 135 °C
Tension 50 Hz [V] 220 V
Tension 50 Hz [V] [max.] 240 V
Type SC
Type de moteur CSR
Type de socle Universel
Utilisation de tronçon Réfrigération LT
Réfrigération MT
Valeur élevée de plage de tension à 50 Hz [V] 264 V
Valeur élevée de plage de tension à 60 Hz [V] 0 V
Valeur élevée de tension nominale à 50 Hz [V] 240 V
Valeur élevée de tension nominale à 60 Hz [V] 0 V
Vitesse de rotation à 50 Hz [rpm] 2900 rpm
Vitesse de rotation à 60 Hz [rpm] 0 rpm
Volume balayé [cm³] 15.28 cm³
Volume de gaz libre [cm3] 1410 cm³
Économiseur No

Documents