Huayi HYB60MGU Compressor 1/7 HP R600a LBP

huayi-hyb60mgu-compressor-1-7-hp-r600a-lbp-mbsmpro

Focus keyphrase: Huayi HYB60MGU Compressor 1/7 HP R600a LBP Technical Specifications Wiring Diagram and Professional Replacement Guide for Domestic Refrigeration Systems

SEO Title: Mbsmpro.com, Compressor, Huayi, HYB60MGU, 1/7 hp, R600a, 110 W, 0.55 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, cooling or freezing

Meta Description: Technical datasheet for the Huayi HYB60MGU compressor. Explore its 1/7 HP capacity, R600a efficiency, electrical wiring schemas, and professional cross-reference replacements.

Slug: huayi-hyb60mgu-compressor-r600a-1-7hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYB60MGU, R600a, 1/7 HP, LBP, Compressor Replacement, EMT45HDR, TLES5.7KK.3, T1112Y, A60CY, ETA60, GL60AA, EMI45HER, TLS5F, B30H

Excerpt: The Huayi HYB60MGU is a high-efficiency hermetic reciprocating compressor specifically engineered for Low Back Pressure (LBP) applications. Operating on the eco-friendly R600a refrigerant, this 1/7 HP unit is a primary component in modern household refrigerators. This guide provides an in-depth technical analysis, electrical wiring configurations, and reliable replacement alternatives for field engineers.


The Engineering Behind the Huayi HYB60MGU: A Technical Standard in R600a Cooling

In the contemporary landscape of domestic refrigeration, the Huayi HYB60MGU represents a cornerstone of energy-efficient design. As a professional who has spent years troubleshooting and installing these units, it is clear that Huayi has optimized the HYB series to meet the rigorous European and international standards for low-temperature performance.

This compressor is a hermetic reciprocating type, designed for Low Back Pressure (LBP) cycles. Its integration of R600a (isobutane) not only aligns with global environmental mandates but also provides superior thermodynamic efficiency compared to legacy R134a systems. For technicians, understanding the mechanical and electrical nuances of the HYB60MGU is essential for ensuring system longevity.

Technical Data Sheet: Huayi HYB60MGU

Feature Specification
Model HYB60MGU
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigerators / Freezers
Oil Type and Quantity Mineral Oil / 180 ml
Horsepower (HP) 1/7 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1 Phase
Cooling Capacity BTU 375 BTU/h (approx. 110 Watts)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 6.0 cm³
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Standard LBP operation)
Capillary Recommendation 0.026″ – 0.028″ ID (Varies by cabinet)
Application Range -35°C to -10°C
Cooling System Static (Natural convection)
Commercial Classification Residential / Household
Amperage (Running) 0.55 A – 0.7 A
LRA (Locked Rotor Amperage) 4.8 A
Type of Relay PTC (Positive Temperature Coefficient)
Capacitor Requirement None (RSIR Configuration)

Electrical Wiring Schema (RSIR Configuration)

The terminal housing of the Huayi HYB60MGU follows a standard triangular pin configuration which is critical for proper startup and protection.

Schema Description:

  • Common (C): The apex pin. This pin connects to the Thermal Overload Protector (OLP), which monitors the motor temperature and current draw.
  • Start (S): The pin usually on the right side. It is momentarily energized by the PTC relay to initiate rotation.
  • Main/Run (M): The pin on the left side. This winding remains energized throughout the operation of the compressor.

Wiring Logic:
Line (Hot) -> Overload Protector -> Common Pin
Neutral -> PTC Relay -> Main Pin & Start Pin

Engineering Note: Always verify the resistance between C-S and C-M. The sum of these two measurements should roughly equal the resistance across S-M. Any significant deviation indicates a winding fault.


Comparative Efficiency: R600a vs. R134a Models

When evaluating the HYB60MGU, it is helpful to compare it against similarly rated R134a compressors to understand the benefits of the modern R600a cycle.

Metric Huayi HYB60MGU (R600a) Standard 1/7 HP (R134a)
Operating Pressure Low / Vacuum High Positive
Displacement 6.0 cm³ 4.5 cm³
Energy Consumption Low (High COP) Moderate
Environment GWP < 3 (Eco-friendly) GWP 1430 (Global Warming)

Professional Replacement Cross-Reference

In repair scenarios where the exact Huayi model is unavailable, these alternatives provide the same cooling capacity and displacement.

5 Replacements in R600a (Same Gas):

  1. Embraco: EMT45HDR (High-reliability alternative)
  2. Secop (Danfoss): TLES5.7KK.3 (Common European replacement)
  3. Jiaxipera: T1112Y (Found in many Beko/Haier units)
  4. Donper: A60CY
  5. Wanbao: ETA60

5 Replacements in R134a (Conversion Required):
Note: Converting from R600a to R134a requires a full system flush and capillary resizing.

  1. Zem: GL60AA
  2. Embraco: EMI 45HER
  3. Secop: TLS5F
  4. Huayi: B30H
  5. Cubigel: GL60AA

Field Engineering Advice and Notices

  • Vacuuming Procedure: Because R600a systems operate at very low pressures, moisture is a catastrophic contaminant. Always pull a vacuum down to at least 200 microns before charging.
  • Charging by Weight: R600a is highly sensitive to overcharging. Always use a digital scale and charge precisely to the manufacturer’s specification (usually 40-60 grams). Do not charge by pressure.
  • Flammability Safety: R600a is isobutane. Ensure no open flames are nearby during charging or discharging. Use “Lokring” cold connections if you are not in a controlled, ventilated environment for brazing.
  • Overload Protection: If the compressor “clicks” but fails to start, check the PTC relay first. These components are prone to cracking due to heat cycles.

Conclusion and Professional Benefit

The Huayi HYB60MGU is a resilient unit that, when maintained correctly, offers years of silent and efficient operation. Its low running amperage makes it an ideal choice for off-grid or solar-powered refrigeration setups where energy conservation is paramount. For the service technician, its standard footprint and predictable electrical behavior make it a preferred model in the field.

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro
Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro



Mbsm.pro, Compressor, BTF60AA, 1/7 hp, r600a, lbp, Serbian Compressor, serie T, from 180 L to 200 L, from 70 to 75 W

Siberia Compressor Catalogue Overview

The Siberia Compressor Catalogue provides detailed specifications and performance data for various compressor series designed for refrigeration systems. These compressors are available in multiple configurations, including R134a and R600a refrigerants, catering to different cooling capacities and applications. Below is an organized breakdown of the catalog’s key sections:


1. Compressor Series Overview

S Series (Low Back Pressure – LBP)

  • Refrigerants: R600a (High Efficiency), R600a (Medium Efficiency), R134a
  • Applications: Suitable for small to medium-sized refrigerators.
  • Key Features:
    • Compact design
    • Low noise and vibration
    • High reliability

V Series (Low Back Pressure – LBP)

  • Refrigerants: R600a, R134a
  • Applications: Ideal for compact refrigeration units.
  • Key Features:
    • Energy-efficient operation
    • Small footprint
    • Environmentally friendly refrigerants

F Series (Low Back Pressure – LBP)

  • Refrigerants: R134a, R600a
  • Applications: Designed for larger refrigeration systems.
  • Key Features:
    • High cooling capacity
    • Multiple motor types (RSIR/RSCR)
    • Robust performance under varying conditions

T Series (Low Back Pressure – LBP)

  • Refrigerants: R600a, R134a
  • Applications: Versatile use in household and commercial refrigeration.
  • Key Features:
    • Very compact size
    • Low noise and vibration
    • High reliability

2. Performance Specifications

Example: T Series Compressors (R600a)

Model
Power (HP)
Displacement (cm³)
Cooling Capacity (W)
Input Power (W)
Rated Current (A)
COP
Oil Charge (ml)
BTF60AA
1/7
6.0
105
74 / 70
0.52 / 0.40
1.42 / 1.50
180
BTF60AA®
1/7
6.0
105
68 / 64
0.50 / 0.34
1.54 / 1.65
180
BTR60AA©
1/7
6.0
105
66 / 60
0.42 / 0.29
1.60 / 1.75
180

Example: S Series Compressors (R600a)

Model
Displacement (cm³)
Motor Type
Cooling Capacity (W)
Input Power (W)
Rated Current (A)
COP
Oil Charge (ml)
BSR51AA
5.1
RSCR
92
53
0.26
1.75
200
BSR58AA
5.8
RSCR
105
60
0.29
1.75
200
BSR68AA
6.8
RSCR
120
69
0.33
1.75
200

3. Special Requirements for Refrigerants

R134a Compressors

  • The open time of the compressor connection pipe should not exceed 10 minutes .
  • Use dedicated vacuum pumps and charging equipment for R134a.
  • Avoid using organic substances incompatible with R134a in the refrigeration system.
  • Ensure strict control of moisture, impurities, paraffin, silicone oil, and chloride ions.

R600a Compressors

  • Follow safety protocols for hydrocarbon refrigerants during installation and operation.
  • Do not tamper with the pre-filled specialized oil in the compressor.
  • Use appropriate tools and equipment to ensure safe handling of R600a.

4. Refrigerator Size Estimation

The cooling capacity of a compressor determines the refrigerator size it can support. For example:

  • BTF60AA (1/7 HP):
    • Cooling Capacity: 105 W
    • Approximate Refrigerator Size: 157.5 – 210 liters
      • Calculation:

5. Outline Drawings and Packaging

Each compressor model includes detailed outline drawings and packaging specifications. For instance:

  • Packaging Dimensions:
    • Carton Size:
    • Container Capacity: Up to 28 units per container.

6. General Requirements for Installation and Operation

  • Store compressors in a dry, well-ventilated area.
  • Avoid tilting or inverting during transportation.
  • Install within 10 minutes after removing protective plugs.
  • Ensure reliable grounding during operation.
  • Avoid high-voltage or vacuum conditions during startup.

To determine the refrigerator size (in liters) that a 1/7 HP compressor can cool, we need to refer to the performance data of the compressors listed in the provided files. Specifically, the BTF60AA compressor (1/7 HP) is a good reference point for this calculation.

Key Specifications for BTF60AA (1/7 HP):

  • Cooling Capacity: 105 W
  • Refrigerant: R600a
  • Voltage: 220-240V / 50Hz

The cooling capacity of a compressor directly correlates with the volume of the refrigerator it can cool. Typically:

  • 1 W of cooling capacity can cool approximately 1.5 to 2 liters of refrigerator volume.

Calculation:

For the BTF60AA compressor with a cooling capacity of 105 W , the approximate refrigerator volume it can cool is:

Table for 1/7 HP Compressor:

Below is a table summarizing the approximate refrigerator size (in liters) based on the cooling capacity of a 1/7 HP compressor:




Mbsm.pro, Compressor, Zem, HL80AH, R600A, Electrolux Group, 84 w, 1/7 hp, Lbp, Freezer

Exif_JPEG_420



Mbsm.pro, Compressor, 1/7 HP , THG1352YKS, th221-ks-324, Tecumseh, LBP, R134a, 220-240V ~ 50Hz, 1 PH

Informations complémentaires

Gaz frigorifique R134a
Puissance électrique du moto-compresseur (CV) 1/7
220v-50Hz-0.71A-3/16″-1/4″
Hauteur-Longueur-Largeur 220-251-161mm
Huile 0.280Litre
Polyolester-poe
Puissance frigorifique (W) 140
Régime des mesures Température d’évaporation : -23.3 °C – Pression d’évaporation :1.15bar / Température de condensation :54.4°C – Pression de condensation: 14.7bar
Utilisation Refrigérateur de capacité entre 200 et 250 litre

Product Specifications

Performance

Condition Test Voltage (R) Btu/h (R) kcal/h (R) W (I) W (E) Btu/Wh (E) kcal/Wh W/W EVAP TEMP COND TEMP AMBIENT TEMP RETURN GAS LIQUID TEMP
CECOMAF 220V ~ 50HZ 335 84 98 99 3.38 .85 .99 -23°C (-10°F) 55°C (131°F) 32°C (90°F) 32°C (90°F) 55°C (131°F)
ASHRAE 220V ~ 50HZ 460 116 135 108 4.26 1.07 1.25 -23°C (-10°F) 54°C (130°F) 32°C (90°F) 32°C (90°F) 32°C (90°F)
(R) Refrigeration Capacity
(I) Input Power
(E) Efficiency

General

Evaporating Temp. Range:

-34.4°C to -12.2°C (-30°F to 10°F)

Motor Torque:

Low Start Torque (LST)

Compressor Cooling:

Static

Mechanical

Weight:

8

Weight Unit of Measure:

KG

Displacement (cc):

5.01

Oil Type:

Polyolester

Viscosity (cSt):

10

Oil Charge (cc):

243

Electrical

Voltage Range (50 Hz):

195-253

Voltage Range (60 Hz):

N/A

Locked Rotor Amps (LRA):

9

Rated Load Amps (RLA 50 Hz):

.71

Rated Load Amps (RLA 60 Hz):

0

Max. Continuous Current (MCC in Amps):

0

Motor Resistance (Ohm) – Main:

21.76

Motor Resistance (Ohm) – Start:

30.57

MotorType:

PTCCS_IR

Overload Type:

N/A

Relay Type:

N/A



Mbsm.pro, Compressor, B43H, HUAYI, 1/7 Hp, LBP, ACC, CUBIGEL, Danfoss, RSIR , r134a

B43H HUAYI compresseurs hermétiques

Spécifications

Circuit de refroidissement (kCal/h)
84
Convertisseur (la tension d’entrée minimale)
71
COP (W/W)
0,76
Cylindrée (cm3)
4.30
Tension/Fréquence
200-240V/1/50-60Hz
Schéma thérapeutique de Aplicacion
LBP




Brandt Compresseur, L.B.P ,HVY67AA ,220-240/50,1/7 Hp ,Réfrigérateur Congélateur Indesit, r600 ,107w

Descriptif détaillé

Compresseur HVY67AA 1/7 R600 pour réfrigérateur / congélateur – Ariston Indésit 

Ce compresseur HVY67AA 1/7 R600 pour réfrigérateur / congélateur se monte sur les marques et modèles suivants

Référence technique – référence commerciale
Ariston Indésit Hotpoint Scholtes
BFS1221HA F064885
BFS1222HA F064884
INFS1211 F064875
INFS1211UK F064874
RZAAV21G.1 F083751
SC09UFRAI F069091
VR120A F065057

Références équivalentes

Indésit C00277059 – 277059 – C00283417 – 283417 – C00115821 – 115821