www.mbsm.pro, Electrolux GL75AA Refrigerator 1/5 HP, Compressor Cooling solution for Refrigerators

www.mbsm.pro, Electrolux GL75AA Refrigerator 1/5 HP, Compressor Cooling solution for Refrigerators

 

 

Type: Hermetic piston compressors
Producer: ACC
Series: HMBP

Model: GL75AA

General data
Refrigerant: R134a
Discharge element: C
Cooling: S
Maximum ambient temperature [ºC]: 43

Compressor’s data
Cylinder capacity [cm³]: 7,4
Displacement [m³/h]: 1,3
Weight [kg]: 9,9
Oil charge [cm³]: 345
Oil type: ISO VG 19 ESTER

Engine’s data
Engine type: RSIR
Power [KM]: 1/5
Starting element: LST
Power supply: 220V 50Hz
Voltage range: 187-264
Locked rotor current [A]: 11,5
Running winding resistance (25ºC) ]: 11,62
Starting winding resistance (25ºC) ]: 21,21

Electrical data
Relays: 3003
Shielding element: MRP317LZ, T0502, AF15BW
Starting capacitor volume [μF]:

Connections
milimeters inches
Suction tube: 6,5
Service tube: 6,5
Discharge tube: 4,9

 


Cooling capacity [W]
tc \ te -35 -30 -25 -20 -15 -10
40 97 134 180 235 299 372
45 87 121 164 216 277 347
50 78 108 148 197 254 321
55 68 95 132 178 232 296
60 58 83 116 158 210 271

Power input [W]
tc \ te -35 -30 -25 -20 -15 -10
40 106 121 139 160 185 212
45 104 121 141 164 190 219
50 102 121 143 167 195 226
55 101 121 144 171 200 233
60 99 121 146 174 206 240

Current [A]
tc \ te -35 -30 -25 -20 -15 -10
40 0.86 0.92 0.99 1.07 1.16 1.25
45 0.85 0.92 1.00 1.08 1.18 1.28
50 0.85 0.93 1.01 1.10 1.20 1.30
55 0.85 0.93 1.02 1.11 1.22 1.33
60 0.85 0.93 1.03 1.13 1.24 1.36

Mass flow [kg/s]
tc \ te -35 -30 -25 -20 -15 -10
40 7.15 10.58 15.13 20.78 27.56 35.44
45 6.35 9.61 13.99 19.48 26.09 33.82
50 5.54 8.64 12.86 18.19 24.63 32.19
55 4.73 7.67 11.72 16.89 23.17 30.57
60 3.92 6.70 10.59 15.59 21.71 28.94

C.O.P. [W/W]
tc \ te -35 -30 -25 -20 -15 -10
40 0.92 1.11 1.29 1.47 1.62 1.76
45 0.84 1.00 1.16 1.32 1.46 1.58
50 0.76 0.90 1.04 1.18 1.30 1.42
55 0.68 0.79 0.91 1.04 1.16 1.27
60 0.59 0.68 0.79 0.91 1.02 1.13




www.mbsm.pro , LG MA42LBJG Refrigerator Compressor 1/6 Hp , Cooling solution for Refrigerators

www.mbsm.pro , LG MA42LBJG Refrigerator Compressor 1/6 Hp , Cooling solution for Refrigerators

Cooling solution for Refrigerators & Commercial Appliances This M-series reciprocating LBP compressor provides complete cooling solution for Domestic & Commercial refrigeration appliances. Compact Size, Silent operation, Low Voltage start ability (LVS) are its prominent features. M-Series compressor caters to 6s quality assurance and has globally proven reliability.
Highlights Cooling Capacity General Specification
Type LBP Type kcal/h 96 Displacement(CC) 4.2
Voltage(V) 220 W 111 EER Btu/Wh 4.0
Frequency(Hz) 50 Btu/h 381 Performance
(As per ASHRAE)
ASHRAE -23.3°C/ 54.4°C @ 50 Hz
Power Consumption (W) 96
Refrigerant R134a

 

 

 




www.mbsm.pro , Embraco FG 75 HAK ,true cooler compressor, 1/4hp

FG 85 HAK,
FG 75 HAK,
FFU 80 HAK ,
FFU 100 HAK,
FG 65 HAK ,
EMYE 70 HEP,
EMT 60 HLP,
EMT 49 HLP ,
EMIE 65 HER ,
EMIE 40 HJP,
EMI 70 HER ,
EM 55 HNR ,
EM 45 HNR ,
EM 30 HHR ,
EGAS 100 HLR ,
EGAS 90 HLR ,
EGAS 80 HLR ,




Mbsm.pro, Aid Mabrouk 2018 Tous Les Musulmans , Php Code

Aîdkoum Mabrouk à tout les musulmans en cette fête de l’Eid el Kebir.

 

Mbsm.pro et son équipe vous souhaite Aïd Moubarak Saïd.

Que cette fête de l’aïd el Adha soit l’occasion de vous réunir en famille et que la paix et la prospérité soit avec vous tous.

Que dire pour souhaiter une bonne fête de l’aïd?

Aïd Moubarak Saïd ou Aïd Mabrouk sont les formules les plus utilisées pour se souhaiter une bonne fête de l’aïd.

 

Aid Moubarak signifie a peu prés: “Que cette fête soit bonne pour vous” ou “Que Dieu vous bénisse ce jour de fête de l’Aïd”.

 

Pour les fêtes de l’Aïd El Kébir et de l’Aïd el fitr,  La formule la plus correct pour se souhaiter une bonne fête est:

Aïdoukoum Moubarak Saïd wa ta9abballa Allah mina wa minkoum. 
( Bonne fêtes de l’aïd et que dieu accepte nos prières)

Formules à utiliser pour souhaiter l’aïd

La réponse classique est:
Allah y barek fik (que la bénédiction d’Allah soit sur toi)

Aïdkoum Mabrouk

Dans la pratique, le musulman dira souvent: Saha aïdkoum, Aïd Moubarak Saïd, Aïd Mabrouk ou Aïdkoum Mabrouk si on s’adresse à plusieurs personnes.

 

On peut dire aussi: “Saha Aidkoumou” ou “Aïd Adha Moubarak

 

Doit on dire Aïd mabrouk?

 

Les spécialistes de la langue arabe déconseillent d’utiliser le terme Aïd mabrouk pour souhaiter une bonne fête de l’Aïd Al Adha ou de l’Aïd El fitr.

 

On utilise aussi l’expression Mabrouk aussi pour se souhaiter un bon ramadan.

Mabrouk Ramadan” fait partie du langage courant utilisé tous les jours.

 

Il semble, cependant, que le terme Mabrouk en arabe correspondrait plutôt à la traduction: “chameau assis”.

 

Le terme “Moubârak” provient du verbe en arabe (بارَك) qui signifie le fait qu’Allah donne Sa bénédiction.

 

Aïd Moubarak est donc l’expression la plus approprié pour se souhaiter une bonne fêtes de l’Aïd.

[php]
</pre>
<?php
$Mbsmgroup_day = 21 ;
$Mbsmgroup_month = 08 ;
$Mbsmgroup_year = 2018;

echo "Today is ";
//String Date .
list($day,$month,$year,$hour,$min,$sec) = explode("/",date(‘d/m/Y/h/i/s’));
echo $month.’/’.$day.’/’.$year.’ ‘.$hour.’:’.$min.’:’.$sec;
//write date in string .

if( $Mbsmgroup_day = $day ) { if( $Mbsmgroup_month = $month ) {
if( $Mbsmgroup_year = $year ) {
//Calculing .
// if resulte is the same with actuel date string
echo "<br><br>Hello world!<br>What a nice day! Today … Aidkom Mabrouk ";
}
}
}
?>
<pre>

[/php]




Mbsm.pro, COMPARE, K2-C239ELFCEF, AND, LG ,T182SC

The K2-C239ELFCEF appears to be a model of an air conditioning or refrigeration compressor. Based on the search results, here is the relevant information:

Key Specifications of K2-C239 Compressor:

  • Model: K2-C239
  • Nominal Output: 1.40 kW
  • Cooling Capacity:

    • 50Hz: 4080 W (13930 BTU/hr)
    • 60Hz: 4970 W (16965 BTU/hr)

  • Weight: 16 kg
  • Dimensions: 323.8 mm (A) x 312 mm (B) x 274.5 mm (C) 3.

Horsepower (HP) Information:

The nominal output of 1.40 kW translates to approximately 1.2 HP (since 1 kW ≈ 1.34 HP). This makes the K2-C239 suitable for medium-capacity cooling applications, such as window coolers, split coolers, and home dehumidifiers 3.

Applications:

This compressor is designed for use in air conditioning systems, including residential and light commercial cooling units. It is part of the K2 series, which is known for its reliability and efficiency in cooling applications 313.

Additional Notes:

  • The K2-C239 is part of a broader product line that includes variations like K2-C223 and K2-C262, each with slightly different cooling capacities and specifications 3.
  • If you are looking for specific details about the “ELFCEF” variant, it may refer to a customized or region-specific model. You may need to contact the manufacturer or supplier for precise details 13.

For further information, you can refer to the product listings on platforms like Alibaba or manufacturer websites 313. If you need assistance with procurement or technical support, reaching out to the supplier directly is recommended.

Model Variations:

  • The T182SC has multiple variants, such as T182SC.MC0T182SC.UC2, and T182SC.NC1, which may differ slightly in specifications or regional compatibility.

Compatibility:

  • Designed for use with LG HVAC systems, including air conditioners and heat pumps.
  • Likely compatible with LG air conditioning units, such as the LG 18000 BTU Dual Inverter models.

Functionality:

  • Provides basic temperature control features, such as heating and cooling modes.
  • May support additional features like programmable schedules or Wi-Fi connectivity, depending on the variant.

Installation:

  • Typically wall-mounted and designed for easy installation in residential or light commercial settings.
  • Requires proper wiring and configuration to ensure compatibility with the HVAC system.

Applications:

  • Residential Use: Controls temperature in homes, particularly for electric heating systems or air conditioning units.
  • Light Commercial Use: Suitable for small offices, workshops, or other spaces requiring precise temperature control.

Related LG Air Conditioning Products:

The LG T182SC thermostat is often used with LG air conditioning units, such as:

  • LG 18000 BTU Dual Inverter Air Conditioner: Features a Dual Inverter Compressor™ for energy efficiency, rapid cooling, and quiet operation.
  • LG Split Air Conditioner (S18ATC): A 18000 BTU unit with R22 refrigerant, designed for residential use.




Mbsm.pro, Compressor, GM35AF, GM55AF, GM70AF, GM66AF, GM75AF, GM77AF, GM80AF, GM91AF, GM80AF

LBP Compressors with R134A Refrigerant: A Comprehensive Overview

LBP compressors, renowned for their reliability and efficiency, are widely used in various refrigeration applications. This article delves into the specifications of a range of LBP compressors that utilize R134A refrigerant, providing detailed information on their performance parameters and operational characteristics.

Table of Specifications

The table below outlines the key specifications for each model of the LBP compressors:

Model
Displacement (cm³)
Operating Voltage V/Hz
Power HP
Nominal Capacity Kcal
COP W/W
Motor Type
Capacitor Used
GM 35 AF
3.50
187-264V/50Hz
1/10
65
1.05
RSIR/RSCR
2 µF
GM 55 AF
5.48
1/6
118
1.06
3 µF
GM 70 AF
6.64
1/5
158
1.17
4 µF
GM 66 AF
6.60
1/5
147
1.28
4 µF
GM 75 AF
7.39
1/4
172
1.20
4 µF
GM 77 AF
7.70
1/4
165
1.29
4 µF
GM 80 AF
8.10
1/4+
198
1.26
4 µF
GM 91 AF
9.10
1/4+
185
1.29
4 µF
GM 80 AF + kap
8.10
1/4+
198
1.26
CSCR
4 µF

Key Features and Performance Metrics

  1. Displacement : The displacement values range from 3.50 cm³ to 9.10 cm³, indicating the volume of refrigerant that can be compressed per cycle. Higher displacement models like GM 91 AF are suitable for larger cooling capacities.
  2. Operating Voltage : All models operate within the voltage range of 187-264V at a frequency of 50Hz, ensuring compatibility with standard electrical supplies.
  3. Power HP : The power ratings vary from 1/10 HP to 1/4+ HP, reflecting the energy consumption and output capacity of each compressor. Models with higher power ratings, such as GM 80 AF and GM 91 AF, are designed for more demanding applications.
  4. Nominal Capacity : The nominal cooling capacities range from 65 Kcal to 198 Kcal, catering to different cooling requirements. For instance, the GM 80 AF and GM 80 AF + kap models both offer a high cooling capacity of 198 Kcal.
  5. COP (Coefficient of Performance) : The COP values indicate the efficiency of the compressors, with higher values signifying better performance. The GM 66 AF model boasts a COP of 1.28, making it one of the most efficient in the lineup.
  6. Motor Type : Most models feature RSIR/RSCR motor types, known for their robustness and reliability. The GM 80 AF + kap model, however, uses a CSCR motor type, which may offer additional benefits depending on the application.
  7. Capacitor Used : The capacitors used range from 2 µF to 4 µF, aiding in the starting and running of the motors. The GM 80 AF + kap model, with its additional start capacitor, ensures smoother operation under varying load conditions.

Additional Notes

  • All the models listed can be equipped with RUN CAPACITORS upon request, enhancing their performance and longevity.
  • The GM 80 AF + kap model is specifically designed with an additional start capacitor, making it ideal for applications requiring enhanced starting torque.

In conclusion, the LBP compressors with R134A refrigerant offer a versatile range of options to meet diverse cooling needs. Their robust design, coupled with high efficiency and reliability, makes them a preferred choice for various refrigeration systems.

 




Mbsm.pro, Comprehensive Guide to Danfoss Compressors: Specifications, Applications, and Selection Tips

Danfoss compressors are widely recognized for their reliability and efficiency in various refrigeration and air conditioning systems. This article provides a detailed overview of the specifications of different Danfoss compressor models, focusing on capillary length, oil quantity, horsepower, and their respective applications.

Introduction to Danfoss Compressors

Danfoss is a global leader in engineering solutions, particularly in the field of refrigeration and air conditioning. Their compressors are designed to meet the demanding requirements of both commercial and residential applications. The compressors are known for their durability, energy efficiency, and low noise levels.

Key Specifications

The following table outlines the key specifications of various Danfoss compressor models:

Capillary Length (Feet) Capillary Length (cm) Capillary NO Oil Hp (Horsepower) Compressor No
4 Feet 121.92 cm 0.26 150 ml 1/14 TL2A
4 Feet 121.92 cm 0.26 150 ml 1/12 TL2.5A
4 Feet 121.92 cm 0.26 150 ml 1/12 TL2.5B
4 Feet 121.92 cm 0.26 150 ml 1/14 PW3K6
4 Feet 121.92 cm 0.26 150 ml 1/12 PW3K7
6 Feet 182.88 cm 0.26 175 ml 1/10 PW3.5K7
6 Feet 182.88 cm 0.26 175 ml 1/10 TL3B
7.5 Feet 228.6 cm 0.28 200 ml 1/8 TL4B
7.5 Feet 228.6 cm 0.28 200 ml 1/8 TL4A
7.5 Feet 228.6 cm 0.28 200 ml 1/8 PW4.5K9
7.5 Feet 228.6 cm 0.28 200 ml 1/8 PW4.5K7
7.5 Feet 228.6 cm 0.28 200 ml 1/8 PW4.5K11
7.5 Feet 228.6 cm 0.28 200 ml 1/8 TFS4AT
9 Feet 274.32 cm 0.31 250 ml 1/6 TL5A
9 Feet 274.32 cm 0.31 250 ml 1/6 PW5.5K11
9 Feet 274.32 cm 0.31 250 ml 1/6 PW5.5K9
9 Feet 274.32 cm 0.31 250 ml 1/6 TFS5AT
9 Feet 274.32 cm 0.31 250 ml 1/6 FR6B
10 Feet 304.8 cm 0.31 275 ml 1/5 FR7.5A
10 Feet 304.8 cm 0.31 275 ml 1/5 FR7.5B
10 Feet 304.8 cm 0.31 300 ml 1/4 FR8.5A

Detailed Analysis

  1. Capillary Length: The capillary length varies from 4 feet (121.92 cm) to 10 feet (304.8 cm). The length of the capillary tube is crucial as it affects the refrigerant flow and system efficiency.
  2. Capillary Number: This parameter indicates the internal diameter of the capillary tube, which influences the refrigerant flow rate. The capillary number ranges from 0.26 to 0.31.
  3. Oil Quantity: The oil quantity in the compressors ranges from 150 ml to 300 ml. Proper oil levels are essential for lubrication and cooling of the compressor components.
  4. Horsepower (Hp): The horsepower of the compressors varies from 1/14 Hp to 1/4 Hp. This indicates the power output and suitability for different cooling capacities.
  5. Compressor Number: Each compressor model has a unique identifier, such as TL2A, PW3K6, etc. These numbers help in identifying the specific model and its application.

Applications

Danfoss compressors are used in a variety of applications, including:

  • Commercial Refrigeration: Models like TL2A and TL2.5A are commonly used in small commercial refrigeration units.
  • Residential Air Conditioning: Compressors such as PW3K6 and PW3K7 are suitable for residential air conditioning systems.
  • Industrial Cooling: Higher capacity models like FR7.5A and FR8.5A are used in industrial cooling applications.

Conclusion

Danfoss compressors offer a wide range of models to meet diverse refrigeration and air conditioning needs. Understanding the specifications, such as capillary length, oil quantity, and horsepower, is essential for selecting the right compressor for your application. With their robust design and efficient performance, Danfoss compressors continue to be a preferred choice in the industry.

Mbsm_dot_pro_private_PDFmbsm.pro-Mbsmpro Comprehensive Guide to Danfoss Compressors Specifications Applications and Selection Tips




Mbsm.pro, Compressor , Tecumseh, KULTHORN

AZ Fridge Freezer Compressor Model AE R134

MODEL HP BTU/h APPL. ENGINE LRA FLORIDA PRICE
AZ1327Y 1/15 229 PSL RSIR 6,70 0,50 N / A
AZ1320Y 1/20 194 PSL RSIR 5:30 p.m. 0,48 N / A
AZ1330Y 1/8 270 PSL RSIR 6.46 0,55 N / A
AZ1335Y 1/8 317 PSL RSIR 8:30 am 0,73 N / A
AZ1340Y 1/5 358 PSL RSIR 6,90 0,75 N / A
AZ1350Y 1/5 409 PSL RSIR 8.70 0,77 N / A
AE1320Y 1/20 194 PSL RSIR 5.40 0,54 N / A
AE1330Y 1/8 270 PSL RSIR 5.44 0,55 N / A
AE1340Y 1/6 375 PSL RSIR 7.00 0,77 N / A
AE1350Y 1/6 461 PSL RSIR 12h00 0,90 N / A
AE1360Y 1/5 539 PSL RSIR 10.00 1,00 N / A
AE1370Y 1/5 635 PSL RSIR 12h60 1.17 N / A
AE1390Y 1/4 860 PSL RSIR 14.10 1.28 N / A
AE2370Y 1/5 631 PSL CSIR 6,50 1.18 N / A
AE2390Y 1/4 809 PSL CSIR 9h20 1.40 N / A
AE2410Y 1/3 921 PSL CSIR 12.75 2,00 N / A
AE2413Y 3/8 1 126 PSL RSE 12,90 1.40 N / A
AEA2415Y 1/2 1 262 PSL RSE 11h60 1.34 N / A
AE2417Y 1/6 1 706 RAP RSIR 11:50 a.m. 1,60 N / A
AE2425Y 1/5 2 491 RAP RSIR 13h60 2.20 N / A
AE3440Y 3/8 3 634 RAP RSIR 11:30 a.m. 3,00 N / A
AE4425Y 1/5 2 388 RAP CSIR 10h70 2.15 N / A
AE4430Y 1/3 2 798 RAP CSIR 12h00 2,50 N / A
AE4435Y 3/8 3 078 RAP CSIR 14.10 2,70 N / A
AE4440Y 1/2 3 668 RAP CSIR 14h70 3.10 N / A
AE4448Y 1/2 4 060 RAP CSIR 23,90 3.45 N / A
AE4459Y-SR 1/2 4 947 RAP RSE 15h70 3,00 N / A
AE7415Y 1/4 1 259 MBP CSIR 11:50 a.m. 1,82 N / A
AE7423Y 1/3 1 958 MBP CSIR 18h50 2.28 N / A
AE7430Y 1/2 2 542 MBP RSE 12.75 2.18 N / A
AE9437Y-SR 5/8 3 139/5 732 MBP/RAP RSE 16h30 2,64/3,50 N / A
Model Application Voltage Horse Power Refrigerant Displacement (CC)
AE1345A-FZ1A LBP 220-240V 1PH 50Hz 1/6 HP R-401A 4.24
AE1360A-FZ1A LBP 220-240V 1PH 50Hz 1/5 HP R-401A 6.12
AE1370A-FZ1A LBP 220-240V 1PH 50Hz 1/4 HP R-401A 6.69
AE1380A-GS1B LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/4 HP R-401A 7.56
AE1390A-FZ1B LBP 220-240V 1PH 50Hz 1/4 HP R-401A 8.02
AE1390Y-AA1A LBP 115V 1PH 60Hz 1/5 HP R-134a, R-513A 8.02
AE1390Y-FZ1A LBP 220-240V 1PH 50Hz 1/5 HP R-134a 8.02
AE1410A-FZ1B LBP 220-240V 1PH 50Hz 1/3 HP R-401A 8.85
AE1420Z-FZ1B LBP 220-240V 1PH 50Hz 1/2 HP R-404A 9.35
AE2390Y-FZ1A LBP 220-240V 1PH 50Hz 1/5 HP R-134a 8.02
AE2410A-AA1A LBP 115V 1PH 60Hz 1/4 HP R-12 9.39
AE2410P-FZ1A LBP 220-240V 1PH 50Hz 1/4 HP R-454C, R-455A 5.02
AE2410U-FZ1A LBP 220-240V 1PH 50Hz 1/4 HP R-290 6.12
AE2410Y-AA1A LBP 115V 1PH 60Hz 1/4 HP R-134a, R-513A 9.39
AE2410Y-FZ1A LBP 220-240V 1PH 50Hz 1/5 HP R-134a 9.39
AE2410Z-AA1A LBP 115V 1PH 60Hz 1/4 HP R-404A, R-407A, R-448A, R-449A, R-452A 5.02
AE2410Z-DS1A LBP 115-127V 1PH 60Hz 1/4 HP R-404A 5.02
AE2410Z-FZ1A LBP 220-240V 1PH 50Hz 1/4 HP R-404A 5.02
AE2410Z-GS1A LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/4 HP R-404A 5.02
AE2413A-AA1B LBP 115V 1PH 60Hz 1/3 HP R-12 12.01
AE2413A-FZ1A LBP 220-240V 1PH 50Hz 1/3 HP R-401A 12.01
AE2413U-AA1A LBP 115V 1PH 60Hz 1/3 HP R-290 7.33
AE2413Y-AA1B LBP 115V 1PH 60Hz 1/3 HP R-134a, R-513A 12.01
AE2413Y-FZ1A LBP 220-240V 1PH 50Hz 1/4 HP R-134a 12.01
AE2413Z-DS1A LBP 115-127V 1PH 60Hz 1/3 HP R-404A 6.12
AE2413Z-GS1A LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-404A 6.12
AE2415A-FZ1B LBP 220-240V 1PH 50Hz 1/2 HP R-401A 12.48
AE2415P-FZ1B LBP 220-240V 1PH 50Hz 1/3 HP R-454C, R-455A 7.33
AE2415U-AA1A LBP 115V 1PH 60Hz 1/3 HP R-290 8.85
AE2415U-FZ1A LBP 220-240V 1PH 50Hz 1/3 HP R-290 8.85
AE2415Y-FZ1B LBP 220-240V 1PH 50Hz 1/2 HP R-134a 12.48
AE2415Y-GH1B LBP 230V 1PH 50Hz 1/2 HP R-134a 12.48
AE2415Y-GH3C LBP 230V 1PH 50Hz 1/2 HP R-134a 12.48
AE2415Z-AA1A LBP 115V 1PH 60Hz 1/3 HP R-404A, R-407A, R-448A, R-449A, R-452A 7.33
AE2415Z-DS1A LBP 115-127V 1PH 60Hz 1/3 HP R-404A 7.33
AE2415Z-FZ1B LBP 220-240V 1PH 50Hz 1/3 HP R-404A 7.33
AE2415Z-GS1A LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-404A, R-407A, R-448A, R-449A, R-452A 7.33
AE2420P-FZ1B LBP 220-240V 1PH 50Hz 1/2 HP R-454C, R-455A 9.33
AE2420U-AA1A LBP 115V 1PH 60Hz 1/2 HP R-290 10.96
AE2420U-FZ1B LBP 220-240V 1PH 50Hz 1/2 HP R-290 10.96
AE2420U-GS1B LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-290 10.96
AE2420Z-AA1B LBP 115V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 9.35
AE2420Z-DS1B LBP 115-127V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 9.33
AE2420Z-ES1A LBP 220V 1PH 60Hz 1/2 HP R-404A 9.33
AE2420Z-GS1B LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 9.33
AE2425P-FZ1C LBP 220-240V 1PH 50Hz 1/2 HP R-454C, R-455A 12.01
AE2425Z-AA3C LBP 115V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 12.01
AE2425Z-FZ1C LBP 220-240V 1PH 50Hz 1/2 HP R-404A 12.01
AE2425Z-FZ3C LBP 220-240V 1PH 50Hz 1/2 HP R-404A 12.01
AE2425Z-GS3B LBP 220V 1PH 50Hz, 220V 1PH 60Hz 3/4 HP R-404A 12.01
AE2425Z-GS3C LBP 220V 1PH 50Hz, 220V 1PH 60Hz 3/4 HP R-404A 12.01
AE2430U-ES3C LBP 220V 1PH 60Hz 3/4 HP R-290 14.51
AE2430Z-AA3C LBP 115V 1PH 60Hz 1 HP R-404A 14.51
AE2430Z-FZ3C LBP 220-240V 1PH 50Hz 1 HP R-404A 14.51
AE2430Z-GS3C LBP 220V 1PH 50Hz, 220V 1PH 60Hz 1 HP R-404A 14.51
AE3425A-AA1A CBP, HBP 115V 1PH 60Hz 1/5 HP R-12 6.69
AE3425Y-AA1A CBP, HBP 115V 1PH 60Hz 1/5 HP R-134a, R-513A 6.69
AE3430Y-AA1A CBP, HBP 115V 1PH 60Hz 1/4 HP R-134a, R-513A 8.02
AE3440Y-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-134a, R-513A 10.33
AE3440Y-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/3 HP R-134a 10.3
AE3440Y-XN1A CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/3 HP R-134a, R-513A 10.33
AE4425E-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/5 HP R-22 4.24
AE4425N-FZ1A HBP 220-240V 1PH 50Hz 1/5 HP R-1234yf, R-134a 6.69
AE4425P-FZ1A HBP 220-240V 1PH 50Hz 1/5 HP R-454C, R-455A 4.24
Model Application Voltage Horse Power Refrigerant Displacement (CC)
AE4425U-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/5 HP R-290 5.02
AE4425Y-AA1A CBP, HBP 115V 1PH 60Hz 1/5 HP R-134a, R-513A 6.69
AE4425Y-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/5 HP R-134a 6.69
AE4425Y-GS1A CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/4 HP R-134a, R-513A 6.69
AE4425Z-AA1A CBP, HBP 115V 1PH 60Hz 1/5 HP R-404A, R-407A, R-448A, R-449A, R-452A 4.24
AE4425Z-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/5 HP R-404A 4.24
AE4425Z-GS1A HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/5 HP R-404A 4.24
AE4425Z-XN1A CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/5 HP R-404A, R-407A, R-448A, R-449A, R-452A 4.24
AE4430A-AA1A CBP, HBP 115V 1PH 60Hz 1/4 HP R-12 8.02
AE4430E-DS1A CBP, HBP 115-127V 1PH 60Hz 1/4 HP R-22 5.16
AE4430E-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/4 HP R-22 5.16
AE4430E-GS1A CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-22 5.16
AE4430N-FZ1A HBP 220-240V 1PH 50Hz 1/4 HP R-1234yf, R-134a 8.02
AE4430P-FZ1A HBP 220-240V 1PH 50Hz 1/4 HP R-454C, R-455A 5.16
AE4430U-AA1A CBP, HBP 115V 1PH 60Hz 1/4 HP R-290 6.12
AE4430U-FZ1A HBP 220-240V 1PH 50Hz 1/4 HP R-290 6.12
AE4430Y-AA1A CBP, HBP 115V 1PH 60Hz 1/4 HP R-134a, R-513A 8.02
AE4430Y-DS1A CBP, HBP 115-127V 1PH 60Hz 1/4 HP R-134a 8.02
AE4430Y-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/4 HP R-134a 8.02
AE4430Y-GS1A HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/4 HP R-134a 8.02
AE4430Y-GT1A CBP, HBP 230V 1PH 50Hz, 230V 1PH 60Hz 1/4 HP R-134a 8.02
AE4430Y-XA1A CBP, HBP 100V 1PH 50Hz, 115V 1PH 60Hz 1/4 HP R-134a, R-513A 8.02
AE4430Y-XN1A CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/4 HP R-134a, R-513A 8.02
AE4430Z-AA1A CBP, HBP 115V 1PH 60Hz 1/4 HP R-404A, R-407A, R-448A, R-449A, R-452A 5.16
AE4430Z-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/4 HP R-404A 5.16
AE4430Z-GS1A CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/4 HP R-404A 5.16
AE4435U-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-290 6.91
AE4440A-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-12 10.33
AE4440A-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/3 HP R-401A 10.33
AE4440E-DS1A CBP, HBP 115-127V 1PH 60Hz 1/3 HP R-22 6.69
AE4440E-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/4 HP R-22 6.69
AE4440E-GS1B HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-22 6.69
AE4440N-FZ1A HBP 220-240V 1PH 50Hz 1/3 HP R-1234yf, R-134a 10.33
AE4440P-FZ1A HBP 220-240V 1PH 50Hz 1/3 HP R-454C, R-455A 6.69
AE4440U-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-290 8.02
AE4440U-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/3 HP R-290 8.02
AE4440Y-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-134a, R-513A 10.33
AE4440Y-AC3C CBP, HBP 100-115V 1PH 60Hz, 100V 1PH 50Hz 1/3 HP R-134a, R-513A 10.33
AE4440Y-DS1A CBP, HBP 115-127V 1PH 60Hz 1/3 HP R-134a 10.33
AE4440Y-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/3 HP R-134a, R-513A 10.33
AE4440Y-GH1A CBP, HBP 230V 1PH 50Hz 1/3 HP R-134a, R-513A 10.33
AE4440Y-GH3C HBP 230V 1PH 50Hz 1/3 HP R-134a 10.33
AE4440Y-GS1A CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-134a 10.33
AE4440Y-GT1A HBP 230V 1PH 50Hz, 230V 1PH 60Hz 1/3 HP R-134a 10.33
AE4440Y-LS1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-134a, R-513A 10.33
AE4440Y-UZ1A HBP 230V 1PH 50Hz, 230V 1PH 60Hz 1/3 HP R-134a 10.33
AE4440Y-XN1A CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/3 HP R-134a, R-513A 10.33
AE4440Z-AA1A CBP, HBP 115V 1PH 60Hz 1/3 HP R-404A, R-407A, R-448A, R-449A, R-452A 6.69
AE4440Z-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/3 HP R-404A 6.69
AE4440Z-GS1C HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-404A 6.69
AE4450A-FZ1C CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-401A 13.24
AE4450E-DS1B CBP, HBP 115-127V 1PH 60Hz 1/2 HP R-22 8.02
AE4450E-FZ1B CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-22 8.02
AE4450E-GS1B CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-22 8.02
AE4450N-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-1234yf, R-134a 13.24
AE4450P-FZ1A HBP 220-240V 1PH 50Hz 1/3 HP R-454C, R-455A 8.85
AE4450U-FZ1A HBP 220-240V 1PH 50Hz 1/3 HP R-290 10.33
AE4450Y-AA1A CBP, HBP 115V 1PH 60Hz 1/2 HP R-134a, R-513A 13.24
AE4450Y-DS1B CBP, HBP 115-127V 1PH 60Hz 1/2 HP R-134a 13.24
AE4450Y-ES1B CBP, HBP 220V 1PH 60Hz 1/2 HP R-134a 13.24
AE4450Y-FZ1B HBP 220-240V 1PH 50Hz 1/2 HP R-134a 13.24
AE4450Y-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-134a 13.24
AE4450Y-GS3C CBP, HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-134a 13.24
AE4450Y-XA1A HBP 100V 1PH 50Hz, 115V 1PH 60Hz 1/2 HP R-134a 13.24
Model Application Voltage Horse Power Refrigerant Displacement (CC)
AE4450Y-XN3C CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/2 HP R-134a, R-513A 13.24
AE4450Z-AA1A CBP, HBP 115V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 8.85
AE4450Z-AA3C CBP, HBP 115V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 8.85
AE4450Z-ES1B CBP, HBP 220V 1PH 60Hz 1/2 HP R-404A 8.85
AE4450Z-FS1B CBP, HBP 220V 1PH 50Hz 1/2 HP R-404A 8.85
AE4450Z-FZ1A CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 8.85
AE4450Z-GS3B HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-404A 8.85
AE4450Z-XN3C CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 8.85
AE4456E-DS1B CBP, HBP 115-127V 1PH 60Hz 1/2 HP R-22 9.39
AE4456E-ES1B CBP, HBP 220V 1PH 60Hz 1/2 HP R-22 9.39
AE4456N-FZ1C HBP 220-240V 1PH 50Hz 1/3 HP R-1234yf, R-134a 14.51
AE4456Y-AA1C CBP, HBP 115V 1PH 60Hz 1/2 HP R-134a, R-513A 14.51
AE4456Y-FZ1C CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-134a 14.51
AE4456Y-GS3C HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-134a 14.51
AE4456Y-XN3C CBP, HBP 200-220V 1PH 50Hz, 208-230V 1PH 60Hz 1/2 HP R-134a, R-513A 14.51
AE4460E-DS1B CBP, HBP 115-127V 1PH 60Hz 1/2 HP R-22 10.33
AE4460E-ES1B CBP, HBP 220V 1PH 60Hz 1/2 HP R-22 10.33
AE4460E-FZ1B CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-22 10.33
AE4460N-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-1234yf, R-134a 15.09
AE4460P-FZ1B HBP 220-240V 1PH 50Hz 1/2 HP R-454C, R-455A 10.33
AE4460U-AA1C CBP, HBP 115V 1PH 60Hz 1/2 HP R-290 12.01
AE4460U-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-290 12.01
AE4460Y-AA3C CBP, HBP 115V 1PH 60Hz 1/2 HP R-134a, R-513A 15.09
AE4460Y-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-134a 15.09
AE4460Y-FZ3C HBP 220-240V 1PH 50Hz 1/2 HP R-134a 15.09
AE4460Y-GH3C HBP 230V 1PH 50Hz 1/2 HP R-134a 15.09
AE4460Y-GS3C HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-134a 15.09
AE4460Y-XB3C CBP, HBP 200V 1PH 50Hz, 230V 1PH 60Hz 1/2 HP R-134a 15.09
AE4460Z-AA1C CBP, HBP 115V 1PH 60Hz 1/2 HP R-404A 10.33
AE4460Z-FZ1C HBP 220-240V 1PH 50Hz 1/2 HP R-404A 10.33
AE4460Z-GS3C HBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/2 HP R-404A 10.33
AE4470E-ES3C CBP, HBP 220V 1PH 60Hz 3/4 HP R-22 13.24
AE4470E-FZ3C CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-22 13.24
AE4470P-FZ3C HBP 220-240V 1PH 50Hz 1/2 HP R-454C, R-455A 12.01
AE4470Z-AA3C CBP, HBP 115V 1PH 60Hz 1/2 HP R-404A, R-407A, R-448A, R-449A, R-452A 12.01
AE4470Z-ES3C HBP 220V 1PH 60Hz 1/2 HP R-404A 12.01
AE4470Z-FS3C HBP 220V 1PH 50Hz 1/2 HP R-404A 12.01
AE4470Z-FZ3C CBP, HBP 220-240V 1PH 50Hz 1/2 HP R-404A 12.01
AE5465C-FZ3C AC, HBP 220-240V 1PH 50Hz 1/2 HP R-407C 10.33
AE5470C-FZ3C AC, HBP 220-240V 1PH 50Hz 1/2 HP R-407C 12.01
AEA1360AGS LBP 220V 1PH 50Hz, 220V 1PH 60Hz   R-12 7.55
AEA2410AES LBP 220V 1PH 60Hz   R-12 12.04
AEA2413ZKS LBP 220-240V 1PH 50Hz   R-404A 10.1
AEA3440YDS HBP 115-127V 1PH 60Hz 1/3 HP R-134a 12.04
AEA4440YKS HBP 220-240V 1PH 50Hz   R-134a 12.04
AEA5470EDS AC, HBP 100V 1PH 50Hz, 115-127V 1PH 60Hz 1/2 HP R-22 13.24
AEA9415EDS CBP 115-127V 1PH 60Hz 1/3 HP R-22 5.67
AEA9422EDS CBP 115-127V 1PH 60Hz 1/3 HP R-22 7.57
AEB1360AXA LBP 100V 1PH 50Hz, 115V 1PH 60Hz   R-12 7.55
AED2413ZXA LBP 100V 1PH 50Hz, 115V 1PH 60Hz 1/2 HP R-404A 11.3
AED2414YGZ LBP 208-220V 1PH 50Hz 1/3 HP R-134a 16
AED2415ZHZ LBP 208-220V 1PH 60Hz 1/2 HP R-404A 12.54
AEW415Y-DS8B LBP, MBP 115-127V 1PH 60Hz 1/3 HP R-134a 12.48
AEW415Y-DS8C LBP, MBP 115-127V 1PH 60Hz 1/2 HP R-134a 12.48
AEW415Y-ES8A LBP, MBP 220V 1PH 60Hz 1/2 HP R-134a 12.48
AEW415Y-FZ8A LBP, MBP 220-240V 1PH 50Hz 1/3 HP R-134a 12.48
AEW415Y-GS8B LBP, MBP 220V 1PH 50Hz, 220V 1PH 60Hz 1/3 HP R-134a 12.48
AEX413Y-DS1B LBP 115-127V 1PH 60Hz 1/3 HP R-134a, R-513A 12.01
AEX417U-DS1B LBP, MBP 115-127V 1PH 60Hz 1/3 HP R-290 8.02
AEX419U-DS1B LBP, MBP 115-127V 1PH 60Hz 1/2 HP R-290 9.35
AEX419U-FZ1C LBP, MBP 220-240V 1PH 50Hz 1/3 HP R-290 10.33
AEX424U-DS3C LBP, MBP 115-127V 1PH 60Hz 1/2 HP R-290 12.01
AEX424U-FZ3B LBP, MBP 220-240V 1PH 50Hz 1/2 HP R-290 12.01
AEX428U-DS3C LBP, MBP 115-127V 1PH 60Hz 3/4 HP R-290 13.24
KULTHORN (KK THAILAND)  
1 AZ 1335 Y R134A 1/8 HP    
2 AZ 1340 Y R134A 1/6 HP    
3 AZ 1355 Y R134A 1/5 HP    
4 AE 1370 Y R134A 1/4 HP    
5 AE 1390 Y R134A 1/4 HP    
6 AE 1410 Y R134A 1/3 HP    
           
7 AE 2413 Y R134A 1/3 HP    
8 AE 2415 Y R134A 1/2 HP    
           
9 AE 2425 ZK R404/R507 1/2 HP    
10 AE 2432 ZK R404/R507 5/8 HP    
11 CA 2435 Z R4040 3/4 HP SMALL BODY  
12 CA 2440 Z R4040 1 HP SMALL BODY  
           
13 WJ 2435 ZK R404/R507 3/4 HP    
14 WJ 2440 ZK R404/R507 1 HP NEW  
15 WJ 2450 ZK R404/R507 1 1/4 HP    
16 WJ 2460 ZK R404/R507 1 1/2 HP NEW  
17 AW 2464 ZK R404/R507 1 7/5 HP    
18 AW 2495 ZK R404/R507 2 1/2 HP    
19 AW 2510 ZK R404/R507 3 HP NEW  
20 AW 2512 ZXG R4040 3 1/2 HP NEW  
           
21 AE 4430 Y R134A 1/4 HP    
22 AE 4440 Y R134A 1/3 HP    
23 AE 4448 Y R134A 3/8 HP    
24 AE 4459 Y R134A 1/2 HP    
25 AW 4524 GK R22, R407 2 HP NEW  
           
26 AE 7422 EK R22 1/3 HP    
27 AE 7426 Y R134A 1/2 HP    
28 AE 7440 EK R22 1/2 HP    
29 AE 7457 GK R404, R22 3/4 HP    
           
30 WJ 9460 EK R22 5/8 HP    
31 WJ 9480 EK R22 1 HP    
           
32 WJ 5513 EK R22 1 HP    
33 WJ 5515 EK R22 1 1/4 HP    
34 WJ 5518 EK R22 1 1/2 HP    
           
35 AW 5522 EK R22 2 HP    
36 AW 5524 EK R22 2 HP    
           
37 AW 5530 EK R22 2 1/2 HP    
38 AW 5535 EK R22 3 1/2 HP  
Model Application Voltage Horse Power Refrigerant Displacement (CC)
AEX428U-FZ3B LBP, MBP 220-240V 1PH 50Hz 1/2 HP R-290 13.24
AEX433U-AA3C LBP, MBP 115V 1PH 60Hz 3/4 HP R-290 15.09
AEX433U-DS3C LBP, MBP 115-127V 1PH 60Hz 3/4 HP R-290 15.09
AEX433U-FZ3C LBP, MBP 220-240V 1PH 50Hz 3/4 HP R-290 15.09



Mbsm.pro, ACC , Electrolux, Compressors, R404a, CML45FB3N, CML60FB3N, CML80FB3N, CML90FB3N, CMP12FB3N, CMP14FB3N, CMX18FB3N, CMR22FB3N, CMS26FB3N, CMS3OFB3N, CML40TB3N, CML45TB3N, CML60TB3N, CML80TB3N, CML90TB3N, CMP12TB3N, CMP14TB3N, CMX16TB3N, CMX18TB3N, CMR22TB3N, CMS26TB3N, CGL40TB3NR, CGL45TB3NR, CGL60TB3NR, CGL90TB3NR, CGP10RB3N, CGP12TB3NR, CGP14TB3NR, CGX18TB3N, CGX21TB3N, CGS26TB3N, CGS30TB3N, CGS34TB3N

CML45FB3N, CML60FB3N, CML80FB3N, CML90FB3N, CMP12FB3N, CMP14FB3N, CMX18FB3N, CMR22FB3N, CMS26FB3N, CMS3OFB3N, CML40TB3N, CML45TB3N, CML60TB3N, CML80TB3N, CML90TB3N, CMP12TB3N, CMP14TB3N, CMX16TB3N, CMX18TB3N, CMR22TB3N, CMS26TB3N, CGL40TB3NR, CGL45TB3NR, CGL60TB3NR, CGL90TB3NR, CGP10RB3N, CGP12TB3NR, CGP14TB3NR, CGX18TB3N, CGX21TB3N, CGS26TB3N, CGS30TB3N, CGS34TB3N

https://mbsm.pro/wp-content/uploads/uploads/Mbsm-tn-media-Electrolux-Compressor-Data.pdf

 

1. Table of Contents:

  • Page 1: Compressors and condensing units for low-temperature applications using R404a refrigerant.
  • Page 2: Compressors and condensing units for medium/high-temperature applications using R404a refrigerant.
  • Page 3: Compressors and condensing units for medium/high-temperature applications using R134a refrigerant.

2. Key Technical Data:

  • Compressor Type: Compressors are classified based on displacement (cm³/rev) and motor power (HP).
  • Motor Type: CSIR (Capacitor Start Induction Run).
  • Electrical Power: Measured in watts (Watts) and electrical current (FLA) in amperes.
  • Cooling Capacity: Measured in watts (Watts) and varies based on ambient temperature and evaporating temperature.
  • Dimensions and Weight: Dimensions (length, width, height) are provided in millimeters, and weight is given in kilograms.

3. Illustrative Tables:

Table 1: Compressors for Low-Temperature Applications (R404a)

Model Displacement (cm³/rev) Motor Power (HP) Motor Type Electrical Power (Watts) Electrical Current (Amps) Ambient Temp. (°C) Cooling Capacity (Watts) Dimensions (mm) Weight (kg)
CM1A5FB3N 4.6 1/6 CSIR 226 1.6 40 95 – 370 425x325x220 14.5
CM1B0FB3N 6.0 1/5 CSIR 270 1.8 38 122 – 454 425x325x220 16.5
CM1B0FB3N 8.1 1/4 CSIR 345 2.2 38 159 – 548 425x325x220 17.2
CM1B0FB3N 8.6 1/3 CSIR 358 2.2 38 195 – 679 425x335x245 19.2
CM1P12FB3N 12.0 3/8 CSIR 219 2.9 32 263 – 965 425x335x245 22.3
CM1P14FB3N 14.0 1/2 CSIR 572 3.4 32 264 – 999 425x335x245 22.3
CMX13RF3N 18.4 5/8 CSIR 718 3.6 32 358 – 1351 510x350x275 28.0
CM1B22FB3N 21.8 2/3 CSIR 754 3.8 32 355 – 1712 540x385x300 34.0
CMS26FB3N 26.2 3/4 CSIR 890 4.7 32 369 – 2218 525x425x355 39.0
CM53GFB3N 30.0 7/8 CSIR 1130 5.6 32 618 – 2385 545x425x350 39.0

Table 2: Compressors for Medium/High-Temperature Applications (R404a)

Model Displacement (cm³/rev) Motor Power (HP) Motor Type Electrical Power (Watts) Electrical Current (Amps) Ambient Temp. (°C) Cooling Capacity (Watts) Dimensions (mm) Weight (kg)
CM140TB3N 4.0 1/5 CSR 348 2.0 32 205 – 687 425x325x235 14.6
CM145TB3N 4.5 1/4 CSR 385 2.2 32 221 – 728 425x325x235 14.7
CM160TB3N 5.7 1/3 CSR 477 2.8 32 274 – 907 425x330x245 22.7
CM180TB3N 7.6 3/8 CSR 570 3.3 32 420 – 1300 450x355x270 23.5
CM190TB3N 8.9 1/2 CSR 700 4.0 32 434 – 1433 425x335x270 23.9
CMIP12TB3N 12.0 1/2 CSR 860 4.1 32 598 – 2023 450x355x350 29.8
CMIP14TB3N 14.0 5/8 CSR 1000 4.9 32 631 – 2172 450x355x350 29.9
CMX16TB3N 16.0 1 CSR 1163 5.8 32 751 – 2385 450x355x350 30.0
CMX18TB3N 18.4 11/8 CSR 1370 7.0 32 812 – 2425 450x355x350 30.0
CMR22TB3N 21.2 11/4 CSR 1228 6.3 32 885 – 3213 450x355x350 30.0
CM52BTB3N 25.9 11/2 CSR 1772 9.0 32 1218 – 4023 450x355x350 30.0

Table 3: Compressors for Medium/High-Temperature Applications (R134a)

Model Displacement (cm³/rev) Motor Power (HP) Motor Type Electrical Power (Watts) Electrical Current (Amps) Ambient Temp. (°C) Cooling Capacity (Watts) Dimensions (mm) Weight (kg)
CG1401r83NR 4.0 1/8 CSIR 219 1.4 32 87 – 455 425x325x210 14.5
CG1451r83NR 4.5 1/6 CSIR 237 1.4 32 111 – 503 425x325x210 14.5
CG1601r83NR 5.7 1/5 CSIR 270 1.7 32 154 – 623 425x325x235 17.0
CG1301r83NR 8.8 1/4 CSIR 385 2.3 32 717 – 945 425x340x245 18.5
CGP10RB3N 10.2 1/3 CSIR 452 2.7 32 502 – 1123 425x350x270 19.5
CGP12T83NR 12.1 3/8 CSIR 602 3.6 32 529 – 1229 425x350x270 20.0
CGP14T83NR 14.0 3/8 CSIR 665 4.0 32 301 – 1354 425x350x270 21.5
CGX18T83N 18.4 1/2 CSIR 845 5.1 32 394 – 1811 510x361x297 26.0
CGX21T83N 20.7 5/8 CSIR 1001 5.8 32 454 – 2057 480x450x312 29.0
CGS26T83N 25.9 3/4 CSIR 1120 6.85 32 541 – 3182 525x425x355 36.0
CGS30T83N 30.0 7/8 CSIR 1170 6.4 32 627 – 3340 545x425x350 39.0
CGS34T83N 34.4 1 CSIR 1352 7.0 32 707 – 3340 545x425x350 39.0

4. Explanations and Analysis:

A. Compressor Applications:

  • Low-Temperature Applications: These compressors are used in refrigeration systems that require low temperatures, such as refrigerators and freezers. The refrigerant used is R404a.
  • Medium/High-Temperature Applications: These compressors are used in air conditioning and refrigeration systems that operate at higher temperatures, such as air conditioners and commercial refrigeration systems. The refrigerants used are R404a and R134a.

B. Cooling Capacity:

  • Cooling capacity varies based on ambient temperature and evaporating temperature. The lower the evaporating temperature, the lower the cooling capacity of the compressor.
  • Larger compressors (with higher displacement) provide higher cooling capacity.

C. Dimensions and Weight:

  • Larger compressors weigh more and take up more space, requiring appropriate system design for installation.

D. Compatibility with Other Refrigerants:

  • All models are suitable for use with R507 and R407B refrigerants, providing flexibility in refrigerant selection based on application and local regulations.

5. Conclusion:

  • Electrolux offers a wide range of compressors and condensing units to meet various cooling needs, whether for low-temperature or medium/high-temperature applications.
  • The provided technical data helps in selecting the appropriate compressor based on required cooling capacity, environmental conditions, and available installation space.

 




Horsepower Units Demystified: A Comprehensive Guide to Specs, Efficiency, and Selection

Discover the Perfect Unit for Your Needs!

Whether you’re upgrading industrial equipment or selecting machinery for a specialized project, choosing the right horsepower (HP) unit is crucial for efficiency and performance. Check out our detailed specifications below to find the ideal match for your requirements!


Specifications Overview: Horsepower Units

HP Length (cm) Width (cm) Height (cm) Blades Blade Length (mm) Blade Spacing (mm) Motor Size (cm) Weight (kg)
1/3 HP 115 485 425 12 24 126 108 116
1/4 HP 105 485 425 11 22 126 108 106
1/5 HP 95 485 425 10 20 126 108 96
1/6 HP 85 485 425 9 18 126 108 86
1/7 HP 75 485 425 8 16 126 108 76
1/8 HP 65 485 425 7 14 126 108 66
1/9 HP 55 485 425 6 12 126 108 56
1/10 HP 45 485 425 5 10 126 108 46
1/12 HP 35 485 425 4 8 126 108 36

Why Choose These Units?

✅ Precision Design: Uniform dimensions (485cm width × 425cm height) ensure compatibility and easy integration.
✅ Scalable Power: Options from 1/3 HP to 1/12 HP cater to diverse industrial and commercial needs.
✅ Optimized Blades: Blade length and spacing tailored for maximum airflow and efficiency.
✅ Lightweight Build: Lower HP models (e.g., 1/12 HP at 36kg) are perfect for portable applications.


Key Considerations

  • Motor Size: All units feature a 108cm motor, ensuring consistent performance across the range.
  • Blade Configuration: More blades in higher HP units enhance airflow for demanding environments.
  • Weight-to-Power Ratio: Balance portability and power based on your project’s demands.