Copeland Model is from 2HP-30JP with high machining accuracy and numerous advantages: small volume, light weight, high efficiency, low vibration and high reliability which will largely replace the traditional piston compressor and has been widely used in the developed countries.
1.With high and low voltage protection, relief valve, the motor overload protection device etc.
2.Easier maintenance, longer service life, design life of 15 years.
3.No internal reciprocating motion mechanism, so the simple structure, small volume, light weight.
4.Less Parts (especially vulnerable part), all parts are sealed inside the acoustic enclosure, at the bottom of the compressor is equipped with elastic damping device; Minimize the noise problem.
5.Torque changes little, high balance, little vibration, stable running, within the scope of its adaptive capacity have higher efficiency.
6.Compact structure, light weight, large capacity, power consumption province, can work continuously for a long time.
Compressor
Code
Capacity
Input
Current
Weight
Height
Norminal
Power
Power Supply
BTU
W
KW
A
kg
mm
HP
CR37KQ
27000
9170
3.13
9.4
31.8
376
3
220V/380V
50HZ-60HZ
CR47KQ
31500
11300
3.81
11.5
33.6
388
3.5
220V/380V
50HZ-60HZ
CR53KQ
36000
12400
4.3
12
33.6
388
4
220V/380V
50HZ-60HZ
CRGQ-0250
22500
7850
2.76
8.52
30.4
375
2.5
220V/380V
50HZ-60HZ
CRHQ-0275
24750
8200
2.89
9.38
30.4
375
2.75
220V/380V
50HZ-60HZ
CRJQ-0300
27000
9170
3.13
10.23
31.8
381
3
220V/380V
50HZ-60HZ
CRPQ-0450
40500
13400
4.56
14.6
38.1
428
4.5
380V
50HZ-60HZ
CRNQ-0500
45000
15000
5.02
13.4
38.1
409
5
380V
50HZ-60HZ
QR90K1
67500
21700
7.58
22.1
67.6
468
7.5
380V
50HZ-60HZ
QR12M1
90000
28200
10.1
29.5
69.4
468
10
380V
50HZ-60HZ
QR15M1
108000
34900
12.9
38.6
72.6
468
12
380V
50HZ-60HZ
Description
Copeland Hermetic Compressor CRJQ-0300-PFV
Note: Product image may vary and is for your reference only.
Get to know our wide range of Copeland Hermetic Compressors, Copeland Semi-Hermetic Compressors, Copeland Discus Compressors, Copeland Scroll Compressors (Tandem and trio), and Copeland Screw Compressors. We have for sale all its components, accessories and parts for their repair and replacement.
We have Repair and Remanufacturing in Semi-hermetic and Screw-type models.
Copeland Hermetic Compressor CRJQ-0300-PFV
Technical Data CRJQ-0300-PFV
HCFC, R-22, 50 Hz, 1 -phase, 200 V
Air conditioning
Performance
Evaporator Temp(ºF) 45 45
Condensing Temp(ºF) 130 100
Return Gas (ºF) 65 65
Liquid Temp (ºF) 115 85
Capacity (Btu/hr) 31200 42300
Power (W): 3130 2600
Current (Amps): 16.9 14.2
EER (Btu/Wh): 10.0 16.3
Mass Flow (Ibs/hr): 457 545
Sound Data
Sound Power (dBA): 72 Avg 77 Max
Vibration (mils(peak-peak)): 1.8 Avg 2.8 Max
Record Date: 2004-08-19
Mechanical
Displ(in^3/Rev): 4.18
Displ(ft^3/hr): 420.47
Overall Length (in): 9.44
Overall Width (in): 9.13
Overall Height (in): 14.81
Mounting Length (in): 7.50
Mounting Width (in): 7.50
Mounting Height (in): 15.19*
Suction Size (in): 3/4 trozo
Discharge Size (In): 3/8 trozo
Initial Oil Charge (oz): 55
Oil Recharge (oz): 51
Net Weight (ibs): 69.0
Internal Free Volume (in^3): 395.0
Horse Power: NA
*Overall compressor height on Copeland Brand Product´s specified mounting grommets.
Electrical
LRA-High*: 93.0
LRA Low *: NA
LRA-Half Winding: NA
MCC (Amps): 31.5
Max Operating Current: NA
RLA(=MCC/1.4;use for contactor selection): 22.5
RLA(=MCC/1.56;use for breaker & wire size selection): 20.2
RPM: 2900
UL File No: SA-2337
UL File Date: 1984-12-28
*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.
Our company is the agent of eminent brand compressor which includes GMCC, LG, SAMSUNG, SANYO, DAIKIN, providing the best performance compressors.
Variety model
In order to offer you a range of different products of air conditioning compressor and refrigeration compressor, our range covers single, twin, two stage rotary compressor and low pressure and high pressure of scroll compressor.It enables to provide you with complete support in every application of your needs.
Quality
With product quality and safety evaluation system that implements basic quality and safety evaluation of products at every production stage. Under the quality gate system, all of our products are subject to safety checks in each quality section on the basis of reference, to prevent shipments of products with quality and safety issues.
We have also achieved quality and sustainability recognition from Europe, North America, China and Japan.
Customer Support
We promise to deliver a satisfactory level to all phases of your business that exceeds our customers’ expectations, and strive to provide the highest value to our customers through prompt, accurate and outstanding service and solution as your business partner.
Rated voltage
Model
Effort
Run RPM
ASHRAE
cooling type
Cooling capacity
Enter
efficiency
CLEAR
policeman
HONOR
[V-Hertz]
kcal/hour
watt
BTU/h
IN
kcal/watt hour
W / W
BTU/watt-hour
BLDC 115V ~ 60HZ
MKV172C-L2J
115-60
1800
110
128
437
72
1.53
1.78
6.07
heart rate
2200
135
157
536
90
1.5
1.74
5.96
2880
176
205
699
120
1.47
1.71
5.82
3480
212
247
842
151
1.4
1.63
5.57
3600
223
259
885
160
1.39
1.62
5.53
MKV190C-L2B
115-60
1800
146
170
580
89
1.64
1.91
6.51
heart rate
2200
174
202
691
107
1.63
1.89
6.46
2880
227
264
901
145
1.57
1.82
6.22
3480
274
319
1088
186
1.47
1.71
5.85
3600
294
342
1167
200
1.47
1.71
5.84
MKV190C-L2J
115-60
1800
146
170
580
93
1.57
1.83
6.23
heart rate
2200
174
202
691
113
1.54
1.79
6.11
2880
227
264
901
152
1.49
1.74
5.93
3480
274
319
1088
195
1.41
1.63
5.58
3600
294
342
1167
210
1.4
1.63
5.56
BLDC 220-240V ~ 50HZ، 220V ~ 60HZ
MKV172G-L2J
220-60
1800
110
128
437
72
1.53
1.78
6.07
heart rate
2200
135
157
536
90
1.5
1.74
5.96
2880
176
205
699
120
1.47
1.71
5.82
3480
212
247
842
151
1.4
1.63
5.57
3600
223
259
885
160
1.39
1.62
5.53
MKV190G-L2B
220-60
1800
146
170
580
89
1.64
1.91
6.51
heart rate
2200
174
202
691
107
1.63
1.89
6.46
2880
227
264
901
145
1.57
1.82
6.22
3480
274
319
1088
186
1.47
1.71
5.85
3600
294
342
1167
200
1.47
1.71
5.84
MKV190G-L2J
220-60
1800
146
170
580
93
1.57
1.83
6.23
heart rate
2200
174
202
691
113
1.54
1.79
6.11
2880
227
264
901
152
1.49
1.74
5.93
3480
274
319
1088
195
1.41
1.63
5.58
3600
294
342
1167
210
1.4
1.63
5.56
BLDC 200-240V ~ 50HZ، 220V ~ 60HZ
* NC1MV43ALP
220-60
1200
45
52
179
31
1.45
1.69
5.76
ST
2000
76
88
302
50
1.52
1.77
6.03
3000
112
130
445
76
1.47
1.71
5.85
4300
146
170
580
110
1.33
1.54
5.27
* NC1MV43ALR
220-60
1200
45
52
179
32
1.41
1.64
5.58
ST
2000
76
88
302
51
1.49
1.73
5.92
3000
112
130
445
78
1.44
1.67
5.7
4300
146
170
580
112
1.3
1.52
5.18
* NC1MV60ALP
220-60
1200
65
76
258
41
1.59
1.84
6.29
ST
2000
111
129
441
69
1.61
1.87
6.39
3000
158
184
627
102
1.55
1.8
6.15
4300
211
245
838
143
1.48
1.72
5.86
* NC1MV60ALR
220-60
1200
65
76
258
42
1.55
1.8
6.14
ST
2000
111
129
441
71
1.56
1.82
6.21
3000
158
184
627
104
1.52
1.77
6.03
4300
211
245
838
145
1.46
1.69
5.78
BLDC 200-240V ~ 50HZ، 220V ~ 60HZ
MSV162A-L1J
220-60
1400
80
93
318
56
1.43
1.66
5.67
ST
2000
105
122
417
70
1.5
1.74
5.96
3000
155
180
615
105
1.48
1.72
5.86
4000
210
244
834
143
1.47
1.71
5.83
MSV162A-L1B
220-60
1200
60
70
238
43
1.4
1.62
5.54
ST
2000
105
122
417
68
1.54
1.8
6.13
3000
155
180
615
103
1.5
1.75
5.97
4300
225
262
893
160
1.41
1.64
5.58
NC1MV72ALP
220-60
1200
80
93
318
51
1.57
1.82
6.23
ST
2000
137
159
544
84
1.63
1.9
6.47
3000
193
224
766
125
1.54
1.8
6.13
4300
270
314
1072
182
1.48
1.73
5.89
* NC1MV72ALR
220-60
1200
80
93
318
52
1.54
1.79
6.11
ST
2000
137
159
544
86
1.59
1.85
6.32
3000
193
224
766
127
1.52
1.77
6.03
4300
270
314
1072
185
1.46
1.7
5.79
MSV172A-L1B
220-60
1200
67
78
266
50
1.34
1.56
5.32
ST
2000
123
143
488
79
1.56
1.81
6.18
3000
192
223
762
125
1.54
1.79
6.1
4300
256
298
1016
188
1.36
1.58
5.41
NC1MV82ALP
220-60
1200
90
105
357
59
1.53
1.77
6.06
ST
1700
135
157
536
83
1.63
1.89
6.46
3000
221
257
877
143
1.55
1.8
6.14
4300
307
357
1219
209
1.47
1.71
5.83
* NC1MV82ALR
220-60
1200
90
105
357
61
1.48
1.72
5.86
ST
1700
135
157
536
85
1.59
1.85
6.31
3000
221
257
877
146
1.51
1.76
6.01
4300
307
357
1219
213
1.44
1.68
5.72
Note: * It is under advanced model
FC cooling type : OC cooling fan: ST cooling oil: constant
Technical Data of Air-cooled medium & High Temperature Unit
Condensing Unit model
CompressormodelCompressormodel _
Power Supply
Cooling capacity W
Power consumption KW
Air Condenser Air-cooled
By tube size
Heat exchange area m 2
Total air volume m 3 /h
Blade diameter mm
Motor power W
number of poles
back gas
discharge
LH34/2HC2.2FH
2HC-2.2
380V 3Ph 50Hz
3380
1.62
18
3000
400
300
4
16
10
LH34/2GC2.2FH
2GC-2.2
3990
1.87
18
3000
400
300
4
16
10
LH44/2FC3.2FH
2FC-3.2
4820
2.31
25
3000
400
300
4
16
12
LH44/2EC3.2FH
2EC-3.2
5670
2.61
25
3000
400
300
4
22
12
LH64/2CC4.2FH
2CC-4.2
8350
3.67
35
3000
400
300
4
22
12
LH84/4FC5.2FH
4FC-5.2
9640
4.12
55
5000
450
370
4
22
12
LH84/4EC6.2FH
4EC-6.2
11850
5.12
55
5000
450
370
4
28
12
LH94/4DC7.2FH
4DC-7.2
14480
6.14
70
6000
400
2×300
4
28
16
LH104-1/4CC9.2FH
4CC-9.2
17500
7.5
80
6000
400
2×300
4
28
16
LH104-2/4VCS10.2FH
4VCS-10.2
19190
7.43
95
10000
450
2×370
4
28
16
LH114/4NCS12.2FH
4NCS-12.2
23150
9.13
110
10000
450
2×370
4
35
16
LH135-1/4PCS15.2FH
4PCS-15.2
27700
10.45
130
14000
500
2×550
4
35
22
LH135-2/4G20.0FH
4G-20.2
32300
13.08
155
14000
500
2×550
4
42
22
LH135-3/4H25.2FH
4H-25.2
42250
16.09
180
14000
550
2×550
4
54
22
LH240/4G30.2FH
4G-30.2
48500
19.02
240
20000
450
4×370
4
54
22
FV300/6H35.2FH
6H-35.2
63400
24.20
300
27000
600
3×550
6
54
28
FV350/6G40.2FH
6G-40.2
72800
28.50
350
36000
650
3×550
6
54
28
FV410/6F50.2FH
6F-50.2
86300
35.40
410
45000
700
3×550
8
54
35
Note: Working conditions for vaporizing temperature at -5℃ condesing temperature at 50℃, and used by R22 refriger ant.
Technical Data of Bitzer Air-cooled units
Air-cooled medium & High Temperature Unit
Condensing Unit model
Compressor model
Overall size(mm)
Installation size
Mounting Aperture
long A
wide B
High C
long F
Wide E
LH34/2HC2.2FH
2HC-2.2
600
650
580
560
400
4-Φ13
LH34/2GC2.2FH
2GC-2.2
600
650
580
560
400
4-Φ13
LH44/2FC3.2FH
2FC-3.2
680
680
600
640
400
4-Φ13
LH44/2EC3.2FH
2EC-3.2
680
680
600
640
400
4-Φ17
LH64/2CC4.2FH
2CC-4.2
780
680
700
740
400
4-Φ17
LH84/4FC5.2FH
4FC-5.2
880
760
800
840
480
4-Φ17
LH84/4EC6.2FH
4EC-6.2
880
760
800
840
480
4-Φ17
LH94/4DC7.2FH
4DC-7.2
1130
760
700
1090
480
4-Φ17
LH104-1/4CC9.2FH
4CC-9.2
1130
760
700
1090
480
4-Φ17
LH104-2/4VCS10.2FH
4VCS-10.2
1130
760
800
1090
480
4-Φ17
LH114/4NCS12.2FH
4TCS-12.2
1340
860
760
1300
580
4-Φ17
LH135-1/4PCS15.2FH
4PCS-15.2
1490
860
960
1450
580
4-Φ17
LH135-2/4G20.0FH
4G-20.2
1490
860
960
150
580
4-Φ20
LH135-3/4H25.2FH
4H-25.2
1590
860
960
1550
580
4-Φ20
LH240/4G30.2FH
4G-30.2
1590
860
1360
1550
580
4-Φ20
FV300/6H35.2FH
6H-35.2
1040
360
800
800
320
4-Φ20
FV350/6G40.2FH
6G-40.2
1190
360
860
950
320
4-Φ20
FV410/6F50.2FH
6F-50.2
1490
360
860
1250
320
4-Φ20
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Air-cooled units
Technical Data of Air-cooled medium & low Temperature Unit
condensing Unit model
Compressor model
Power Supply
Cooling capacity W
Power consumption KW
Condenser Air-cooled
By tube size
Heat exchange area m 2
Total air volume m 3 /h
Blade diameter mm
Power W
number of poles
back gas
discharge
LH34/2FC2.2FM
2FC-2.2
380V 3Ph 50Hz
2700
1.73
18
3000
400
300
4
16
10
LH44/2EC2.2FM
2EC-2.2
3150
2.09
25
3000
400
300
4
22
12
LH44/2CC3.2FM
2CC-3.2
4450
2.79
25
3000
400
300
4
22
12
LH64/4FC3.2FM
4FC-3.2
4960
3.42
35
3000
400
300
4
22
12
LH64/4EC4.2FM
4EC-4.2
6160
4.01
35
3000
400
300
4
22
12
LH74/4DC5.2FM
4DC-5.2
7280
4.67
42
5000
450
370
4
28
12
LH84/4CC6.2FM
4CC-6.2
8390
5.67
55
5000
450
370
4
28
12
LH94/4TcS8.2FM
4TCS-8.2
11880
6.90
70
6000
400
2×300
4
35
16
LH104-1/4PCS10.2FM
4PCS10.2
13800
7.95
80
6000
400
2×300
4
35
16
LH104-2/4NCS12.2FM
4NCS12.2
16150
9.27
95
10000
450
2×370
4
35
16
LH114/4H15.2FM
4H15.2
21100
12.45
110
10000
450
2×370
4
42
22
LH135-1/4G20.2FM
4G20.2
24450
14.88
130
14000
500
2×550
4
54
22
LH135-2/6J22.2FM
6J22.2
27350
16.13
155
14000
500
2×550
4
54
22
LH135-3/6H25.2FM
6H25.2
31700
18.70
180
14000
500
2×550
4
54
22
LH240/6G30.2FM
6G30.2
36700
22.30
240
20000
450
4×370
4
54
22
FNV300/6F40.2FM
6F40.2
44100
27.10
300
27000
600
3×550
6
54
28
Working conditions for vaporizing temperature at -20℃ condesing temperature at 50℃, and used by R22 refriger ant CIC necessary when the vaporizing temperature is low.
Technical Data of Bitzer Air-cooled units
Installation size of Air-cooled medium & Low Temperature Unit
Condensing Unit model
Compressor model
Overall size(mm)
Installation size
Mounting Aperture
long A
wide B
High C
long F
Wide E
LH34/2FC2.2FM
2FC-2.2
600
650
580
560
400
4-Φ13
LH44/2EC2.2FM
2EC-2.2
680
680
600
640
400
4-Φ13
LH44/2CC3.2FM
2CC-3.2
680
680
600
640
400
4-Φ17
LH64/4FC3.2FM
4FC-3.2
780
680
700
740
400
4-Φ17
LH64/4EC4.2FM
4EC-4.2
780
680
700
740
400
4-Φ17
LH74/4DC5.2FM
4DC-5.2
880
760
800
840
480
4-Φ17
LH84/4CC6.2FM
4CC-6.2
880
760
800
840
480
4-Φ17
LH94/4TCS8.2FM
4TCS-8.2
1130
760
700
1090
480
4-Φ17
LH104-1/4PCS10.2FM
4PCS10.2
1130
760
700
1090
480
4-Φ17
LH104-2/4NCS12.2FM
4NCS12.2
1130
760
800
1090
480
4-Φ17
LH114/4H15.2FM
4H15.2
1340
860
760
1300
580
4-Φ17
LH135-1/4G20.2FM
4G20.2
1490
860
960
1450
580
4-Φ17
LH135-2/6J22.2FM
6J22.2
1490
860
960
1450
580
4-Φ20
LH135-3/6H25.2FM
6H25.2
1590
860
960
1550
580
4-Φ20
LH240/6G30.2FM
6G30.2
1590
860
1360
1550
580
4-Φ20
FNV300/6F40.2FM
6F40.2
1190
360
860
950
320
4-Φ20
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Water-cooled units
Technical Data of Water-cooled medium & High Temperature Unit
Unit Type
Compressor Model
Power KW
Cooling capacity W
Return air (mm)
Liquid supply (mm)
water pipe G
Water supply (m 3 /h)
WN4/2FC3.2WH
2FC3.2
2.00
5590
Φ16
Φ12
3/2″
2
WN5/2CC4.2WH
2CC4.2
3.31
9890
Φ22
Φ16
3/2″
2.5
WH8/4FC5.2WH
4FC5.2
3.66
11230
Φ22
Φ16
3/2″
3.3
WH8/4EC6.2WH
4EC6.2
4.56
13860
Φ22
Φ16
3/2″
4.0
WH10/4DC7.2WH
4DC7.2
5.40
16830
Φ28
Φ19
3/2″
4.8
WH10/4CC9.2WH
4CC9.2
6.64
20250
Φ28
Φ19
2″
6.5
WH15/4VCS10.2WH
4VCS10.2
6.61
22250
Φ28
Φ19
2″
6.9
WH15/4TCS12.2WH
4TCS12.2
8.09
26800
Φ35
Φ19
2″
8.0
WH15/4PCS15.2WH
4PCS15.2
9.35
31950
Φ42
Φ22
2″
9.2
WH20/4NCS20.2WH
4NCS20.2
11.34
37000
Φ42
Φ22
2″
12.0
WH25/4J22.2WH
4J22.2
12.25
40900
Φ42
Φ22
2″
13.5
WH30/4H25.2WH
4H25.2
14.20
47400
Φ54
Φ22
5/2″
14.0
WH35/4G30.2WH
4G30.2
16.76
54400
Φ54
Φ22
5/2″
16.5
WH40/6H35.2WH
6H35.2
21.30
71200
Φ54
Φ28
5/2″
21.8
WH45/6G40.2WH
6G40.2
25.20
81600
Φ54
Φ28
5/2″
24.5
WH50/6F50.2WH
6F50.2
31.4
96500
Φ54
Φ28
3″
29.0
Note: Working conditions for vaporizing temperature at -5℃ condesing temperature at 40℃, and used by R22 refriger ant. It working for 380 50Hz
Technical Data of Bitzer Water-cooled units
Installation size of water-cooled Medium & High Temperature Unit
Unit Model
Compressor Model
Overall size(mm)
Installation size (mm) Installation size
Mounting aperture mm
long A
wide B
High H
long E
wide F
WN4/2FC3.2WH
2FC3.2
1010
350
720
780
300
Φ18
WN5/2CC4.2WH
2CC4.2
1010
350
720
780
300
Φ18
WN8/4FC5.2WH
4FC5.2
1080
350
760
850
300
Φ18
WN8/4EC6.2WH
4EC6.2
1080
350
760
850
300
Φ18
WN10/4DC7.2WH
4DC7.2
1120
350
800
890
300
Φ18
WN10/4CC9.2WH
4CC9.2
1120
350
800
890
300
Φ18
WN15/4VCS10.2WH
4VCS10.2
1220
400
850
990
350
Φ18
WN15/4NCS12.2WH
4NCS12.2
1220
400
850
990
350
Φ18
WN15/4PCS15.2WH
4PCS15.2
1220
400
850
990
350
Φ18
WN20/4NCS20.2WH
4NCS20.2
1220
400
850
990
350
Φ18
WN25/4J22.2WH
4J22.2
1320
400
950
1080
350
Φ18
WN30/4H25.2WH
4H25.2
1620
400
950
1400
350
Φ18
WN35/4G30.2WH
4G30.2
1620
400
950
1400
350
Φ18
WN40/6H35.2WH
6H35.2
1620
400
950
1400
350
Φ18
WN45/6G40.2WH
6G40.2
1900
400
1000
1680
350
Φ18
WN50/6F50.2WH
6F50.2
1900
400
1000
1680
350
Φ18
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Technical Data of Bitzer Water-cooled units
Technical Data of Work-cooled medium & low Temperature Unit
Unit Model
Compressor Model
power
Cooling capacity
back gas
liquid supply
water pipe
Water supply
KW
IN
mm
mm
G
m 3 /h
WN04/2CC3.2WM
2CC-3.2
2.6
5500
22
12
1-1/2
1.5
WN05 / 4EC4.2WM
4EC-4.2
3.7
7550
22
16
1-1/2
2.5
WN08/4DC5.2WM
4DC-5.2
4.4
8830
28
16
1-1/2
3.0
WN08 / 4CC6.2WM
4CC-6.2
5.2
10230
28
16
1/1/2
3.5
WN10/4TCS8.2WM
4TCS-8.2
6.4
14150
35
22
1-1/2
4.5
WN10/4PCS10.2WM
4PCS-10.2
7.4
16390
35
22
2
5.5
WN15 / 4NCS12.2WM
4VCS-12.2
8.7
19160
35
22
2
6.0
WN20 / 4H15.2WM
4H-15.2
11.2
24450
42
25
2
7.8
WN25/4G20.2Wm
4G-20.2
13.1
28200
54
28
2
9.0
WN30/6H25.2WM
6H-25.2
16.8
36700
54
28
2
12.0
WN35/6G30.2WM
6G-30.2
19.6
42300
54
28
2-1/2
14.5
WN45 / 6F40.2WM
6F-40.2
24.3
50500
54
28
2-1/2
16.8
Working conditions for vaporizing temperature at -20℃ condesing temperature at 50℃, and used by R22 refriger ant CIC necessary when the vaporizing temperature is low.
Technical Data of Bitzer Water-cooled units
Installation size of Water cooled Medium & Low Temperature Unit
Unit Model
Compressor Model
Overall size(mm)
Installation size (mm) Installation size
Mounting Aperture
long A
wide B
High H
long E
wide F
WN04/2CC3.2WM
2CC-3.2
1010
350
720
780
300
Φ18
WN05 / 4EC4.2WM
4EC-4.2
1010
350
720
780
300
Φ18
WN08/4DC5.2WM
4DC-5.2
1080
350
760
850
300
Φ18
WN08 / 4CC6.2WM
4CC-6.2
1080
350
760
850
300
Φ18
WN10/4TCS8.2WM
4TCS-8.2
1120
350
800
890
300
Φ18
WN10/4PCS10.2WM
4PCS-10.2
1120
350
800
890
300
Φ18
WN15 / 4NCS12.2WM
4VCS-12.2
1220
400
850
990
350
Φ18
WN20 / 4H15.2WM
4H-15.2
1220
400
850
990
350
Φ18
WN25/4G20.2WM
4G-20.2
1320
400
950
1080
350
Φ18
WN30/6H25.2WM
6H-25.2
1620
400
950
1400
350
Φ18
WN35/6G30.2WM
6G-30.2
1620
400
950
1400
350
Φ18
WN45 / 6F40.2WM
6F-40.2
1900
400
1000
1680
350
Φ18
Note: We reserve the right to modify the above overall and installation sizes without prior notice.
Main Technical Data of Copeland C series semi-hermatic units
Main Technical Data of Air-cooled semi-hermatic units
Unit model
compressor
Cooling capacity R22 (KW)
power supply
Reservoir (L)
Overall size
installation size
Take over tube(mm)
model _
power
mobile phone
KW
long A
wide B
High H
long a
wide b
inhale
liquid supply
FNH28/CA0300AH
CA-0300
3
2.2
5.35
3Ph 380V 50Hz _ _
7.5
720
650
600
680
400
19
10
FNH34/CA0400AH
CA-0400
4
3.0
6.94
7.5
770
650
655
730
400
25
12
FNH41/CA0500AH
CA-0500
5
3.7
7.6
10
820
650
755
770
400
25
12
FNH55/cA0800AH
CA-0800
8
5.5
11.62
15
940
700
860
890
420
32
16
FNH80/cA1000AH
CA-1000
10
7.5
17.63
20
1220
850
960
1170
570
32
16
FNH100/CA1500AH
CA-1500
15
10.5
21.4
25
1440
850
960
1390
580
38
19
Note: working conditions for vaporizing temperature at -15℃ condesing temperature at 30℃, and used by R22 refriger ant
Main Technical Data of Copeland C series semi-hermatic units
Main Technical Data of water-cooled semi-hermatic units
Unit model
compressor
Cooling capacity (KW)
power supply
Overall size
installation size
Take over tube(mm)
In and out water pipes
model _
power
mobile phone
KW
long A
wide B
High H
long a
wide b
inhale
liquid supply
G
WN03/C0300WL
C-0300
3
2.2
5.35
3Ph 380V 50Hz
810
300
650
600
250
19
10
G1
WN04/CA0400WL
CA-0400
4
3.0
6.74
1010
350
720
780
300
25
12
G3 / 2
WN05/C0500WL
C-0500
5
3.7
7.08
1010
350
720
780
300
25
12
G3 / 2
WN08 / CA0800WL
CA-0800
8
5.5
9.76
1080
350
720
850
300
32
16
G3 / 2
WN10/C1000WL
C-1000
10
7.5
14.25
1120
350
800
890
300
32
16
G3 / 2
WN15/C1500WL
C-1500
15
10.5
20.4
1220
400
800
990
350
38
19
G2
Note: working conditions for vaporizing temperature at -15℃ condesing temperature at 30℃, and used by R22 refriger ant