TOSOT TS-H246JAL3

Electrical Schematic & Connection Guide

Since this is a single-phase ($1\phi$) unit, the electrical system relies on a Permanent Split Capacitor (PSC) motor. Below is the technical breakdown of the wiring logic for this 2-ton TOSOT unit:

  • Compressor Wiring: * Common (C): Connects directly to the Overload Protector (Internal).

    • Start (S): Connects to one side of the 50 $\mu$F Capacitor.
    • Run (R): Connects to the Neutral line and the other side of the capacitor.

  • Outdoor Fan Motor: Usually wired in parallel with the compressor power supply, using its own smaller capacitor (typically 5-7 $\mu$F).

Technical Article: TOSOT TS-H246JAL3 Lord Series Analysis

Focus Keyphrase: TOSOT TS-H246JAL3 2 Ton Compressor Specifications and R22 Engineering Guide

SEO Title: Mbsm.pro, TOSOT TS-H246JAL3, 2 Tons, 24000 BTU, R22, 220V, Lord Series Outdoor Unit

Meta Description: Technical deep-dive into the TOSOT TS-H246JAL3 2-ton outdoor unit. Features 23,500 BTU cooling, T3 tropical climate rating, and professional R22 compressor replacement data for HVAC engineers.

Slug: tosot-ts-h246jal3-2-ton-compressor-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, TOSOT, TS-H246JAL3, 2 Ton AC, 24000 BTU, R22 Refrigerant, T3 Tropical Compressor, Panasonic 2K28 replacement, Samsung PH41 replacement.

Excerpt: The TOSOT TS-H246JAL3 is a high-performance 2-ton outdoor air conditioning unit from the Lord Series, specifically engineered for T3 tropical environments. Delivering 23,500 BTU/h of cooling power, this R22-based system is a staple for technicians requiring reliability in extreme heat. This article provides full technical specifications and professional cross-reference guides.


Professional Specification Table

Model Parameter Technical Data
Model TS-H246JAL3
Tonnage 2 Tons
Utilization HBP (High Back Pressure)
Domaine Cooling & Heating (Heat Pump)
Oil Type Mineral Oil (SUNISO 4GS or equivalent)
Horsepower (HP) 2 HP
Refrigerant Type R22
Refrigerant Charge 1.8 Kg
Power Supply 220-240V / 50Hz / $1\phi$
Cooling Capacity 23,500 BTU/h
Heating Capacity 24,000 BTU/h
Motor Type PSC (Permanent Split Capacitor)
Climate Type T3 (Tropical – Up to 52°C)
Running Amperage 10.0 A (Cooling)
LRA (Locked Rotor) 52 A
Capacitor Value 50 $\mu$F / 450V

Performance Comparison: R22 vs. R410A (2-Ton Class)

In the field, the TS-H246JAL3 uses R22, which offers distinct operational differences compared to modern R410A units of the same tonnage.

Feature TOSOT TS-H246JAL3 (R22) Standard 2-Ton (R410A)
Operating Pressure (Suction) 65 – 75 PSI 115 – 130 PSI
Discharge Temperature Moderate High
Compression Ratio Lower (Longer Life) Higher
Oil Sensitivity Low (Mineral) High (POE – Hygroscopic)

Professional Replacement Cross-Reference

If the compressor fails, these models are the gold standard for direct replacement without modifying the chassis:

5 Direct R22 Replacements

  1. Panasonic: 2K28C225A (Industry Standard)
  2. Samsung: PH41VP-ET
  3. LG: QP442PED
  4. Highly: 203DH-32C2
  5. Mitsubishi: RH313VAGT

5 Alternative Replacements (Conversion Required)

  1. GMCC: PA240M2C-4FT (R410A)
  2. Gree: QXF-B239zH070 (R410A)
  3. Panasonic: 5RS092DAA (R410A)
  4. Copeland: ZP24K5E (R410A Scroll)
  5. Tecumseh: RK5515E (R22/R407C)

Engineer’s Notice & Field Advice

  • T3 Climate Advantage: This unit is rated for T3. As an expert, I recommend ensuring the outdoor unit has at least 50cm of clearance from any wall. T3 units move a massive amount of heat; restricting airflow will cause the amperage to spike above the rated 10A, leading to premature winding failure.
  • Capacitor Maintenance: The 50 $\mu$F capacitor is the most common point of failure. If the compressor hums but doesn’t start (drawing high LRA), check the capacitor before condemning the compressor.
  • Charging by Weight: Since the system uses 1.8 Kg of R22, always charge using a digital scale. Overcharging an R22 system in a T3 environment causes liquid slugging and destroys the valve plates.